DC and AC parameters M41T01
18/24 DocID025389 Rev 2
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 12. AC testing input/output waveform
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
3. Outputs deselected.
Table 4. Operating and AC measurement conditions
Parameter M41T01 Unit
Supply voltage (V
CC
) 2.0 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Load capacitance (C
L
) 100 pF
Input rise and fall times 5ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
V
Input and output timing ref. voltages 0.3V
CC
to 0.7V
CC
V
Table 5. Capacitance
Symbol Parameter
(1,2)
Min Max Unit
C
IN
Input capacitance (SCL) 7 pF
C
OUT
(3)
Output capacitance (SDA, FT/OUT) 10 pF
t
LP
Low-pass filter input time constant (SDA
and SCL)
250 1000 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V