FOC-M12-MNNA-TC...
2 / 8 PHOENIX CONTACT 103995_en_02
2 Ordering data
3 Limit values
Loads that exceed the limit values can cause permanent
damage to the component. The limit values represent the
load limits of the component.
Continuous operation with these values is not recom-
mended, as this may jeopardize the reliability of the compo-
nent.
The FO transceiver, connectors, and couplings should only
be mounted finger tight.
Fiber optic transceiver
Description Type Order No. Pcs. / Pkt.
M12 FO transceiver, duplex, wavelength: 650 nm for 125 Mbps, for POF and
PCF fibers, for PCB mounting, M16 fastening thread, with sealing cap, includ-
ing I²C interface for transceiver monitoring and management
FOC-M12-MNNA-TC-650 1416716 1
M12 FO transceiver, duplex, wavelength: 1300 nm for 125 Mbps, for GOF fi-
bers, for PCB mounting, M16 fastening thread, with sealing cap, including I²C
interface for transceiver monitoring and management
FOC-M12-MNNA-TC-1300 1416729 1
Accessories
Description Type Order No. Pcs. / Pkt.
M12 fiber optic coupler, duplex, suitable for all fibers, with wall bracket, IP65
degree of protection
FOC-M12-BU/BU 1416677 1
Assembled FO cable, round cable, 980/1000 μm POF fibers, for in-
stallation inside buildings
M12 FO to M12 FO
1 m FOC-PN-B-1000/M12-C/SCRJ/1
FOC-PN-B-1000/M12-C/SCRJ/2
FOC-PN-B-1000/M12-C/SCRJ/5
1408865
1408864
1416648
1
2 m 1
5 m 1
Assembled FO cable, round cable, 980/1000 μm POF fibers, for in-
stallation inside buildings
M12 FO to SCRJ/IP20
1 m FOC-PN-B-1000/M12-C/M12-C/1
FOC-PN-B-1000/M12-C/M12-C/2
FOC-PN-B-1000/M12-C/M12-C/5
1408871
1408870
1416680
1
2 m 1
5 m 1
Assembled FO cable, round cable, 200/230 μm PCF-GI fibers, for
installation inside buildings
M12 FO to M12 FO
1 m FOC-HCS-GI-1005/M12-C/M12-C/1
FOC-HCS-GI-1005/M12-C/M12-C/2
FOC-HCS-GI-1005/M12-C/M12-C/5
1408873
1408872
1416693
1
2 m 1
5 m 1
Assembled FO cable, round cable, 200/230 μm PCF-GI fibers, for
installation inside buildings
M12 FO to SCRJ/IP20
1 m FOC-HCS-GI-1005/M12-C/SCRJ/1
FOC-HCS-GI-1005/M12-C/SCRJ/2
FOC-HCS-GI-1005/M12-C/SCRJ/5
1408867
1408866
1416651
1
2 m 1
5 m 1
Assembled FO cable, round cable, 50/125 μm GOF-MM fibers, for
installation inside buildings
M12 FO to M12 FO
1 m FOC-M12-M12-GB02/2
FOC-M12-M12-GB02/1
FOC-M12-M12-GB02/5
1408874
1408875
1416703
1
2 m 1
5 m 1
Assembled FO cable, round cable, 50/125 μm GOF-MM fibers, for
installation inside buildings
M12 FO to LC duplex
1 m FOC-M12-LC:A-GB02/1
FOC-M12-LC:A-GB02/2
FOC-M12-LC:A-GB02/5
1408869
1408868
1416664
1
2 m 1
5 m 1
Limit values
Operating temperature -40 °C ... +85°C
Storage temperature -40 °C ... +100°C
Soldering temperature 2 mm from housing, t 5 s 260°C
Supply voltage 4 V
Data input voltage -0.5 V ... 4 V
Differential input voltage 2 V (peak-to-peak with FOC-M12-MNNA-TC-1300)
PECL output current -50 mA ... +50 mA
Electrostatic air discharge in acc. with EN 61000-6-2 8 kV
Electrostatic contact discharge in acc. with EN 61000-6-2 4 kV
Immunity of electrical field in accordance with EN 61000-6-2 10 V/m