HTCM-SCE-TP-1/2-6H-9

RW-2524 Issue 4
Page 13 of 15
Feb’ 2015
©2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
RW-2524 Issue 4
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks
of their respective owners.
If this document is printed it becomes uncontrolled.
PROPERTY
TEST METHOD
UNITS
REQUIREMENTS
RW-2524
SECTION
Tensile Strength
TE test method
101-121002
MPa (Psi)
20.6 (3000) Minimum
4.3.2.
Ultimate Elongation
TE test method
101-121002
%
100 Minimum
4.3.2.
Specific Gravity
TE test method
101-121015
---
1.8 Maximum
4.3.3.
Vacuum Outgassing
TML
(Total Mass Loss)
VCM
(Volatile Condensable
Material)
ASTM E595
%
1.0 Maximum
4.3.4.
%
0.1 Maximum
THERMAL
Heat Ageing
168 hours at 225°C
(437±F), followed by:
Mandrel Bend
Mark Adherence
TE test method
101-121008
Bend around a mandrel
(10 x thickness)
TE Document
109-121012
20 rubs, 1kg load, eraser
---
---
No damage to the
marker and print
Legible, minimum print
contrast 3
4.4.1.
Heat Shock
4 hours at 275°C (527°F),
followed by:
Mandrel Bend
Mark Adherence
TE test method
101-121007
Bend around a mandrel
(10 x thickness)
TE Document
109-121012
20 rubs, 1kg load, eraser
---
---
No damage to the
marker and print
Legible, minimum print
contrast 3
4.4.2.
RW-2524 Issue 4
Page 14 of 15
Feb’ 2015
©2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
RW-2524 Issue 4
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks
of their respective owners.
If this document is printed it becomes uncontrolled.
PROPERTY
TEST METHOD
UNITS
REQUIREMENTS
RW-2524
SECTION
Low Temperature
Flexibility
4 hours at -55°C,
followed by:
Mandrel Bend
Mark Adherence
TE test method
101-121006
Bend around a mandrel
(10 x thickness)
TE Document
109-121012
20 rubs, 1kg load, eraser
---
---
No damage to the
marker and print
Legible, minimum print
contrast 3
4.4.3.
ENVIRONMENTAL
Fungus Resistance
Followed by
Fungus Growth
Rating
Mark Adherence
ASTM G21-96
Visual Inspection
TE Document
109-121012
20 rubs, 1Kg load
---
---
Maximum Rating 1
Legible, minimum print
contrast 3
4.5.1.
Corrosion
16 hours at 200°C (392°F)
TE work instruction
109-121009
---
No Corrosion
4.5.2.
Water Absorption
24 hours at 23°C (73°F)
TE work instruction
109-121016
%
0.5 Maximum
4.5.3.
FIRE SAFETY
Fire Propagation
Airbus Directive ABD0031
Issue F, Fire worthiness
requirements pressured
section of fuselage
(15 s horizontal test AITM
2.0003)
mm/s
(mm/inch)
Burn rate must nor
exceed 102mm/min
(4 inches/min)
4.6.1.
Surface Flammability,
Flame Spread Index, Is
ASTM E162
---
35 Maximum
4.6.2.
RW-2524 Issue 4
Page 15 of 15
Feb’ 2015
©2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
RW-2524 Issue 4
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks
of their respective owners.
If this document is printed it becomes uncontrolled.
PROPERTY
TEST METHOD
UNITS
REQUIREMENTS
RW-2524
SECTION
Specific Optical Smoke
Density, Ds
4.6.3.
Flaming Mode
Specific Optical Density
1.5 minutes
4 minutes
ASTM E 662
---
---
100 Maximum
200 Maximum
Non Flaming Mode
1.5 minutes
4 minutes
---
---
100 Maximum
200 Maximum
Toxic Gas Generation
from Material
Combustion
Carbon Monoxide (CO)
Carbon Dioxide (CO2)
Nitrogen Oxides (NO2)
Sulphur Dioxide (SO2)
Hydrogen Chloride (HCl)
Hydrogen Fluoride (HF)
Hydrogen Bromide (HBr)
Hydrogen Cyanide (HCN)
BSS 7239
Measured at maximum
smoke density. Flaming
mode and non-flaming mode
assessed, worst case
reported.
ppm
Maxima:
3500
90000
100
100
500
100
100
100
4.6.4.
Effective Heat of
Combustion
1
Average Heat Release
Rate, 3 minutes
Average Extinction area, 3
minutes
ASTM E1354
50kWm
2
applied heat flux
with retainer frame
kW/m
2
m
2
/kg
100
Maximum
500
4.6.5.
EN45545-2
Flammability Hazard
Rating for interior mass
500g
(following grouping rules)
Based on the following
criteria:
Oxygen Index (OI)
BS EN ISO 4589-2:1999
%
Requirement Set R24,
Hazard Rating 3
32 Minimum
4.6.6.
1
NFPA 130 does not specify a requirement for small electrical components, the figures stated are based on current best practices for US federal
rail administration and national fire protection association.

HTCM-SCE-TP-1/2-6H-9

Mfr. #:
Manufacturer:
Raychem / TE Connectivity
Description:
Wire Labels & Markers HTCM-SCE-TP-1/2-6H-9
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union