HTCM-SCE-TP-1/2-6H-9

RW-2524 Issue 4
Page 4 of 15
Feb’ 2015
©2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
RW-2524 Issue 4
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks
of their respective owners.
If this document is printed it becomes uncontrolled.
¼ inch 4-Hole Cable Marker
Figure 4: HTCM-SCE-TP-1/4-4H
½ inch 6-Hole Cable Marker
Figure 5: HTCM-SCE-TP-1/2-6H
RW-2524 Issue 4
Page 5 of 15
Feb’ 2015
©2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
RW-2524 Issue 4
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks
of their respective owners.
If this document is printed it becomes uncontrolled.
2.3
Test Requirements
The test requirements shall be as specified in Table 2.
3.
QUALITY ASSURANCE PROVISIONS
3.1.
Qualification Tests
Qualification tests are those performed on finished Cable Marker, continuous sheet or material pellets
submitted for qualification as a satisfactory product and shall consist of all tests listed in this
specification.
Some tests require un-perforated lengths which are not supported by the finished Cable marker
format therefore continuous sheet shall be tested. For this document, ‘Cable Marker’ shall be defined
as specimen that represents the finished article; this is the material taken from the end of the
production line. ‘Continuous strip’ is specimen taken from work in progress and is removed from the
production line prior to finishing. Other than the format, both of these specimens are identical.
3.2.
Acceptance Tests
Acceptance tests are those performed on markers submitted for acceptance under contract.
Acceptance tests shall consist of the following: Dimensions, Heat shock and Mark Adherence
performance
3.3.
Qualification Test Samples
Qualification test samples shall consist of 5m (16 foot) of continuous strip, and at least 500 cable
markers and 1kg of material pellets.
Cable Marker, Continuous Strip and Material pellets shall be taken from the same compound batch.
Unless otherwise specified, the Cable Markers shall be removed from the carrier for testing. Where
required by test method limitations, testing shall be done on marker material
RW-2524 Issue 4
Page 6 of 15
Feb’ 2015
©2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
RW-2524 Issue 4
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks
of their respective owners.
If this document is printed it becomes uncontrolled.
4.
TEST METHODS
4.1
Preparation of Test Specimens
Finished Cable Markers for testing shall be printed with TE approved printers and ribbons (TE
document 411-121005) and printed with Arial size 10 pt font. The initial print contrast must be C8 or
above, reference TE Document 411-121002.
Unless otherwise specified, tests shall be carried out on Cable Markers that have had no pre-
conditioning. When required by the test method, testing shall be made with continuous strip. Unless
otherwise specified, all tests shall be made under standard ambient conditions according to IEC
Publication 60212. In cases of dispute the tests shall be carried out at a temperature of 23±2°C and
at 50±5% relative humidity.
4.2
Print Performance
4.2.1
Mark Adherence
Three Cable Markers shall be prepared as detailed in Clause 4.1 and tested in accordance with TE
test reference 109-121012. Samples shall be tested using a Crockmeter fitted with an eraser and 1kg
load using the number of rubs specified in the requirement table.
After the Mark Adherence test, marking shall be examined for legibility using normal reading vision.
Print contrast shall be measured in accordance with TE Document 411-121002.
4.2.2.
Solvent Resistance
Nine Cable Markers shall be prepared as detailed in Clause 4.1 and tested in accordance with TE test
reference 109-121014.
The marking shall be examined for legibility using normal reading vision. Print contrast shall be
measured in accordance with TE Document 411-121002.
4.2.3.
Fluid Resistance
Three Cable Markers as prepared as in Clause 4.1 shall be completely immersed in each of the fluids
for the times and at the temperatures specified in the requirements table. The volume of the fluid shall
not be less than 20 times that of the specimen. After immersion, the markers are lightly blotted with
tissue paper to remove excess surface fluid and air dried at 23 ± 2°C for 45 ± 15min. The print shall
be tested in accordance with TE test reference 109-121012. Samples are tested with a Crockmeter
fitted with Super Twill’ cloth and a 1kg load.
After the print permanence test, marking shall be examined for legibility using normal reading vision.
Print contrast shall be measured in accordance with TE Document 411-121002.

HTCM-SCE-TP-1/2-6H-9

Mfr. #:
Manufacturer:
Raychem / TE Connectivity
Description:
Wire Labels & Markers HTCM-SCE-TP-1/2-6H-9
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union