7
HCNW4506 Gull Wing Surface Mount Option 300 Outline Drawing
1.00 ± 0.15
(0.039 ± 0.006)
7° NOM.
12.30 ± 0.30
(0.484 ± 0.012)
0.75 ± 0.25
(0.030 ± 0.010)
11.00
(0.433)
5
6
7
8
4
3
2
1
11.15 ± 0.15
(0.442 ± 0.006)
9.00 ± 0.15
(0.354 ± 0.006)
1.3
(0.051)
13.56
(0.534)
2.29
(0.09)
LAND PATTERN RECOMMENDATION
1.78 ± 0.15
(0.070 ± 0.006)
4.00
(0.158)
MAX.
1.55
(0.061)
MAX.
2.54
(0.100)
BSC
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES).
NOTE: FLOATING LEAD PROTRUSION IS 0.25 mm (10 mils) MAX.
0.254
+ 0.076
- 0.0051
(0.010
+ 0.003)
- 0.002)
MAX.
8
Recommended Pb-Free IR Prole
Solder Reow Temperature Prole
0
TIME (SECONDS)
TEMPERATURE (°C)
200
100
50 150100 200 250
300
0
30
SEC.
50 SEC.
30
SEC.
160 °C
140 °C
150 °C
PEAK
TEMP.
245 °C
PEAK
TEMP.
240 °C
PEAK
TEMP.
230 °C
SOLDERING
TIME
200 °C
PREHEATING TIME
150 °C, 90 + 30 SEC.
2.5 C ± 0.5 °C/SEC.
3 °C + 1 °C/–0.5 °C
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
PREHEATING RATE 3 °C + 1 °C/–0.5 °C/SEC.
REFLOW HEATING RATE 2.5 °C ± 0.5 °C/SEC.
NOTE: NON-HALIDE FLUX SHOULD BE USED.
217 °C
RAMP-DOWN
6 °C/SEC. MAX.
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
* 260 +0/-5 °C
t 25 °C to PEAK
60 to 150 SEC.
15 SEC.
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
t
p
t
s
PREHEAT
60 to 180 SEC.
t
L
T
L
T
smax
T
smin
25
T
p
TIME
TEMPERATURE
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200 °C, T
smin
= 150 °C
NOTE: NON-HALIDE FLUX SHOULD BE USED.
* RECOMMENDED PEAK TEMPERATURE FOR WIDEBODY 400mils PACKAGE IS 245 °C
9
Insulation and Safety Related Specications
Value
Parameter Symbol HCPL-4506 HCPL-J456 HCPL-0466 HCNW4506 Units Conditions
Minimum External L(101) 7.1 7.4 4.9 9.6 mm Measured from input
Air Gap (External terminals to output
Clearance) terminals, shortest
distance through air.
Minimum External L(102) 7.4 8.0 4.8 10.0 mm Measured from input
Tracking (External terminals to output
Creepage) terminals, shortest
distance path along body.
Minimum Internal 0.08 0.5 0.08 1.0 mm Through insulation
Plastic Gap distance, conductor to
(Internal Clearance) conductor, usually the
direct distance between
the photoemitter and
photodetector inside the
optocoupler cavity.
Minimum Internal NA NA NA 4.0 mm Measured from input
Tracking (Internal terminals to output
Creepage) terminals, along internal
cavity.
Tracking Resistance CTI ≥175 ≥175 ≥175 ≥200 Volts DIN IEC 112/VDE 0303
(Comparative Part 1
Tracing Index)
Isolation Group IIIa IIIa IIIa IIIa Material Group (DIN
VDE 0110, 1/89, Table 1)
Regulatory Information
The devices contained in this data sheet have been approved by the following agencies:
Agency/Standard HCPL-4506 HCPL-J456 HCPL-0466 HCNW4506
Underwriters Laboratories (UL) UL 1577
Recognized under UL 1577, Component
Recognized Program, Category FPQU2,
File E55361
Canadian Standards Component
Association (CSA) Acceptance
File CA88324 Notice #5
Verband Deutscher DIN VDE 0884
Electrotechniker (VDE) (June 1992)
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01

HCPL-4506-300E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Logic Output Optocouplers 1MBd 1Ch 10mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union