10
Figure 21. Typical low level output 1 voltage
vs. output 1 current, HCPL-3100.
Figure 17. Normalized low to high threshold
input current vs. supply voltage, HCPL-3100.
Figure 19. Normalized low to high threshold
input current vs. ambient temperature,
HCPL-3100.
Figure 15. Typical forward current vs. forward
voltage, HCPL-3100.
Figure 14. Maximum power dissipation
vs. ambient temperature, HCPL-3101.
Figure 16. Typical forward current vs. forward
voltage, HCPL-3101.
Figure 18. Normalized low to high threshold
input current vs. supply voltage, HCPL-3101.
Figure 20. Normalized low to high threshold
input current vs. ambient temperature,
HCPL-3101.
Figure 22. Typical low level output 1 voltage
vs. output 1 current, HCPL-3101.
600
500
400
300
P
O
P
tot
200
100
0
-40 -25 0 25 50
AMBIENT TEMPERATURE T
A
(°C)
POWER DISSIPATION P
O
, P
tot
(mW)
75 85 100 125
100
10
1
0.1
0.50 0.75 1.00 1.25
FORWARD VOLTAGE V
F
(V)
FORWARD CURRENT I
F
(mA)
1.50 1.75 2.00
25°C
T
A
= 100°C
85°C
0°C
-40°C
50°C
100
10
1
0.1
1.0 1.2 1.4 1.6
FORWARD VOLTAGE V
F
(V)
FORWARD CURRENT I
F
(mA)
1.8 2.0 2.2
0°C
T
A
= 85°C
50°C
-40°C
-20°C
25°C
120
100
110
90
70
80
15 18 21
SUPPLY VOLTAGE V
CC
(V)
RELATIVE INPUT THRESHOLD CURRENT (%)
24 27 30
T
A
= 25°C
VALUE OF V
CC
= 24 V
ASSUME 100
120
100
110
90
70
80
15 18 21
SUPPLY VOLTAGE V
CC
(V)
RELATIVE INPUT THRESHOLD CURRENT (%)
24 27 30
T
A
= 25°C
I
FLH
= 100% at V
CC
= 24 V
160
120
140
100
60
80
-40 -20 0 20
AMBIENT TEMPERATURE T
A
(°C)
RELATIVE INPUT THRESHOLD CURRENT (%)
40 60 80 100
V
CC
= 24 V
I
FLH
= 100% at T
A
= 25°C
120
100
110
90
60
80
70
-40 -20 0 20
AMBIENT TEMPERATURE T
A
(°C)
RELATIVE INPUT THRESHOLD CURRENT (%)
40 60 80 100
V
CC
= 24 V
I
FLH
= 100% at T
A
= 25°C
3
2
0
1
0 0.1 0.2
O
1
OUTPUT CURRENT I
O1
(A)
O
1
LOW LEVEL OUTPUT VOLTAGE V
O1L
(V)
0.3 0.4 0.5 0.6
T
A
= 25°C
V
CC1
= 12 V
V
CC2
= -12 V
I
F
= 10 mA
3
2
0
1
0 0.1 0.2
O
1
OUTPUT CURRENT I
O1
(A)
O
1
LOW LEVEL OUTPUT VOLTAGE V
O1L
(V)
0.3 0.4 0.5 0.6
T
A
= 25°C
V
CC1
= 12 V
V
CC2
= -12 V
I
F
= 5 mA
11
Figure 23. Typical low level output 1 voltage
vs. ambient temperature, HCPL-3100.
Figure 25. Typical high level output 2 voltage
vs. supply voltage, HCPL-3100.
Figure 27. Typical high level output 2 voltage
vs. ambient temperature, HCPL-3100.
Figure 31. Typical low level output 2 voltage
vs. ambient temperature, HCPL-3100.
Figure 29. Typical low level output 2 voltage
vs. output 2 current, HCPL-3100.
Figure 24. Typical low level output 1 voltage
vs. ambient temperature, HCPL-3101.
Figure 26. Typical high level output 2 voltage
vs. supply voltage, HCPL-3101.
Figure 28. Typical high level output 2 voltage
vs. ambient temperature, HCPL-3101.
Figure 30. Typical low level output 2 voltage
vs. output 2 current, HCPL-3101.
0.30
0.20
0.15
0.25
0
0.10
0.05
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
O
1
LOW LEVEL OUTPUT VOLTAGE V
O1L
(V)
40 60 80 10020
V
CC1
= 12 V
V
CC2
= -12 V
I
F
= 10 mA
I
O2
= 0.1 A
0.30
0.20
0.15
0.25
0
0.10
0.05
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
O
1
LOW LEVEL OUTPUT VOLTAGE V
O1L
(V)
40 60 80 10020
V
CC1
= 12 V
V
CC2
= -12 V
I
F
= 5 mA
I
O2
= 0.1 A
30
24
21
27
12
18
15
15 18
SUPPLY VOLTAGE V
CC
(V)
O
2
HIGH LEVEL OUTPUT VOLTAGE V
O2H
(V)
24 27 3021
T
A
= 25°C
I
F
= 10 mA
30
24
21
27
12
18
15
15 18
SUPPLY VOLTAGE V
CC
(V)
O
2
HIGH LEVEL OUTPUT VOLTAGE V
O2H
(V)
24 27 3021
T
A
= 25°C
I
F
= 5 mA
24
23
22
20
21
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
O
2
HIGH LEVEL OUTPUT VOLTAGE V
O2H
(V)
40 60 80 10020
V
CC
= 24 V
I
F
= 10 mA
I
O2
NEARLY = 0 A
I
O2
= -0.1 A
24
23
22
20
21
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
O
2
HIGH LEVEL OUTPUT VOLTAGE V
O2H
(V)
40 60 80 10020
V
CC
= 24 V
I
F
= 5 mA
I
O2
= NEARLY 0 A
I
O2
= -0.1 A
3
2
0
1
0 0.1 0.2
O
2
OUTPUT CURRENT I
O2
(A)
O
2
LOW LEVEL OUTPUT VOLTAGE V
O2L
(V)
0.3 0.4 0.5 0.6
T
A
= 25°C
V
CC
= V
O1
= 24 V
I
F
= 0 mA
3
2
0
1
0 0.1 0.2
O
2
OUTPUT CURRENT I
O2
(A)
O
2
LOW LEVEL OUTPUT VOLTAGE V
O2L
(V)
0.3 0.4 0.5 0.6
T
A
= 25°C
V
CC
= V
O1
= 24 V
I
F
= 0 mA
0.8
0.6
0.5
0.7
0.2
0.4
0.3
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
O
2
LOW LEVEL OUTPUT VOLTAGE V
O2L
(V)
40 60 80 10020
V
CC
= 24 V
I
F
= 0 mA
I
O2
= 0.1 A
12
Figure 33. Typical high level supply current
vs. supply voltage, HCPL-3100.
Figure 35. Typical low level supply current
vs. supply voltage, HCPL-3100.
Figure 32. Typical low level output 2 voltage
vs. ambient temperature, HCPL-3101.
Figure 34. Typical high level supply current
vs. supply voltage, HCPL-3101.
Figure 36. Typical low level supply current
vs. supply voltage, HCPL-3101.
Figure 37. Typical high level supply current
vs. ambient temperature, HCPL-3100.
Figure 38. Typical high level supply current
vs. ambient temperature, HCPL-3101.
Figure 39. Typical low level supply current
vs. ambient temperature, HCPL-3100.
Figure 40. Typical low level supply current
vs. ambient temperature, HCPL-3101.
0.8
0.6
0.5
0.7
0.2
0.4
0.3
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
O
2
LOW LEVEL OUTPUT VOLTAGE V
O2L
(V)
40 60 80 10020
V
CC
= 24 V
I
F
= 0 mA
I
O2
= 0.1 A
3.0
2.0
1.5
2.5
0
1.0
0.5
15 18
SUPPLY VOLTAGE V
CC
(V)
HIGH LEVEL SUPPLY CURRENT I
CCH
(mA)
24 27 3021
T
A
= 25°C
I
F
= 10 mA
3.0
2.0
1.5
2.5
0
1.0
0.5
15 18
SUPPLY VOLTAGE V
CC
(V)
HIGH LEVEL SUPPLY CURRENT I
CCH
(mA)
24 27 3021
T
A
= 25°C
I
F
= 5 mA
3.0
2.0
1.5
2.5
0
1.0
0.5
15 18
SUPPLY VOLTAGE V
CC
(V)
LOW LEVEL SUPPLY CURRENT I
CCL
(mA)
24 27 3021
T
A
= 25°C
I
F
= 0 mA
3.0
2.0
1.5
2.5
0
1.0
0.5
15 18
SUPPLY VOLTAGE V
CC
(V)
LOW LEVEL SUPPLY CURRENT I
CCL
(mA)
24 27 3021
T
A
= 25°C
I
F
= 0 mA
3.0
2.0
1.5
2.5
0
1.0
0.5
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
40 60 80 100
20
HIGH LEVEL SUPPLY CURRENT I
CCH
(mA)
V
CC
= 24 V
I
F
= 10 mA
3.0
2.0
1.5
2.5
0
1.0
0.5
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
40 60 80 100
20
HIGH LEVEL SUPPLY CURRENT I
CCH
(mA)
V
CC
= 24 V
I
F
= 5 mA
3.0
2.0
1.5
2.5
0
1.0
0.5
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
40 60 80 100
20
LOW LEVEL SUPPLY CURRENT I
CCL
(mA)
V
CC
= 24 V
I
F
= 0 mA
3.0
2.0
1.5
2.5
0
1.0
0.5
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
40 60 80 100
20
LOW LEVEL SUPPLY CURRENT I
CCL
(mA)
V
CC
= 24 V
I
F
= 0 mA

HCPL-3100-000E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 0.6A IGBT Gate Drive
Lifecycle:
New from this manufacturer.