13
Figure 43. Typical propagation delay time
vs. ambient temperature, HCPL-3100.
Figure 41. Typical propagation delay time
vs. forward current, HCPL-3100.
Figure 42. Typical propagation delay time
vs. forward current, HCPL-3101.
Figure 44. Typical propagation delay time
vs. ambient temperature, HCPL-3101.
2.5
2.0
1.5
0
1.0
0.5
05
FORWARD CURRENT I
F
(mA)
PROPAGATION DELAY TIME t
PHL
, t
PLH
(µs)
15 20 2510
t
PHL
t
PLH
V
CC
= V
O1
= 24 V
R
G
= 47 W
C
G
= 3000 pF
T
A
= 85°C
25°C-40°C
-40°C
85°C
25°C
1.0
0.8
0.6
0
0.4
0.2
05
FORWARD CURRENT I
F
(mA)
PROPAGATION DELAY TIME t
PHL
, t
PLH
(µs)
15 20 2510
t
PHL
t
PLH
V
CC
= V
O1
= 24 V
R
G
= 47 W
C
G
= 3000 pF
T
A
= 85°C
25°C -40°C
-40°C
85°C
25°C
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
40 60 80 100
20
2.5
2.0
1.5
0
1.0
0.5
PROPAGATION DELAY TIME t
PHL
, t
PLH
(µs)
t
PLH
t
PHL
V
CC
= V
O1
= 24 V
R
G
= 47 W
C
G
= 3000 pF
I
F
= 10 mA
-40 -20 0
AMBIENT TEMPERATURE T
A
(°C)
40 60 80 100
20
1.0
0.8
0.6
0
0.4
0.2
PROPAGATION DELAY TIME t
PHL
, t
PLH
(µs)
t
PLH
t
PHL
V
CC
= V
O1
= 24 V
R
G
= 47 W
C
G
= 3000 pF
I
F
= 5 mA
For product information and a complete list of distributors, please go to our website: www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies Limited in the United States and other countries.
Data subject to change. Copyright © 2007 Avago Technologies Limited. All rights reserved. Obsoletes 5989-2939EN
AV01-0573EN July 16, 2007

HCPL-3100-000E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 0.6A IGBT Gate Drive
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: