AXL F DO8/2 2A 1H
8238_en_04 PHOENIX CONTACT 4 / 14
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection IP20
Protection class III, IEC 61140, EN 61140, VDE 0140-1
Mounting position Any (no temperature derating)
General data
Connection data
Designation AxiolineF connector
Connection method Push-in connection
Conductor cross section solid / stranded 0.5 mm² ... 1.5 mm² / 0.5 mm² ... 1.5 mm²
Conductor cross section [AWG] 20 ... 16
Stripping length 8 mm
Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Interface AxiolineFlocal bus
Connection method Bus base module
Transmission speed 100 MBit/s
Communications power
Communications power U
Bus
5 V DC (via bus base module)
Current consumption from U
Bus
max. 150 mA
Power consumption at U
Bus
max. 750 mW
I/O supply
Supply of digital output modules U
O
24 V DC
Maximum permissible voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumption from U
O
max. 16 A (Provide external protection; if the total current of 8A is exceeded,
connect the supply at the power connector parallel via both terminal points.)
Power consumption at U
O
typ. 260 mW (without actuators), max. 480 W (Of which 625mW with internal
losses)
Surge protection of the supply voltage Electronic (35 V, 0.5 s)
Polarity reversal protection of the supply voltage Parallel diode; with external 5A fuse (for startup only)
Protection max. 16 A (polarity reversal protection up to 5A)
When using the module for the first time, protect it with a 5 A fuse. When all modules in the system are correctly connected, the 5 A fuse can
be replaced by a 16 A fuse. You can now load the module up to 16A. Observe the derating.
Loads over 16A are not permitted.
NOTE: Damage to the electronics
Provide the module with an external fuse to protect it against polarity reversal. The power supply unit must be able to supply four times the
nominal current of the external fuse, to ensure that it trips in the event of an error.
Digital outputs
Number of outputs 8
Connection method Push-in connection
Connection method 2-wire
Nominal output voltage 24 V DC
Maximum output current per channel 2 A
Maximum output current per device 16 A (external fuse)
AXL F DO8/2 2A 1H
8238_en_04 PHOENIX CONTACT 5 / 14
Nominal load, ohmic max. 48 W (12 , at nominal load)
Nominal load, inductive max. 48 VA (1.2 H, 12 , at nominal load)
Nominal load, lamp max. 48 W (at nominal voltage)
Signal delay max. 150 µs (when switched on)
max. 150 µs (When switched off; with at least 100mA load current)
Switching frequency max. 3000 per second (with ohmic load)
Switching frequency max. 1 per second (with inductive load)
Switching frequency max. 4 per second (with nominal lamp load)
Load min. 10 k
Energy consumption see diagram
Derating For channel groups 1 ... 4 and 5 ... 8: 8A to30°C, then dropping linearly to 6A
at60°C
Derating diagram for channel groups 1 ... 4 and 5 ... 8
Output voltage when switched off max. 1 V
Output current when switched off max. 300 µA
Behavior with overload Shutdown with automatic restart
Behavior with inductive overload Output can be destroyed
Reverse voltage resistance to short pulses Limited protection up to 0.5 A for 1 s
NOTE: Damage to the electronics
If there is a faulty external voltage (reverse voltage) at one of the outputs, the output may be destroyed. This may cause unintentional setting
of further outputs.
Overcurrent shut-down as of 2.8 A
Output current with ground connection interrupt when switched off < 1 mA
Short-circuit protection, overload protection of the outputs Electronic
Derating For channel groups 1 ... 4 and 5 ... 8: 8A to30°C, then dropping linearly to 6A
at60°C
Digital outputs
I [A]
0
T [°C]
2
4
6
8
0
10 20 30 40 50 60
Configuration and parameter data in a PROFIBUS system
Required parameter data 1 Byte
Need for configuration data 6 Byte
Error messages to the higher level control or computer system
Short-circuit / overload of the digital outputs Yes
Electrical isolation/isolation of the voltage areas
Test section Te s t vo l t a g e
5 V communications power (logic), 24 V supply (I/O) 500 V AC, 50 Hz, 1 min.
5 V supply (logic)/functional earth ground 500 V AC, 50 Hz, 1 min.
24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min.
Mechanical tests
Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6 5g
Shock in acc. with EN60068-2-27/IEC60068-2-27 30g
Continuous shock according to EN60068-2-27/IEC60068-2-27 10g
AXL F DO8/2 2A 1H
8238_en_04 PHOENIX CONTACT 6 / 14
Conformance with EMC Directive 2014/30/EU
Noise immunity test in accordance with EN 61000-6-2
Electrostatic discharge (ESD) EN61000-4-2/IEC61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Electromagnetic fields EN61000-4-3/IEC61000-4-3 Criterion A, Field intensity: 10 V/m
Fast transients (burst) EN61000-4-4/IEC61000-4-4 Criterion B, 2kV
Transient overvoltage (surge) EN61000-4-5/IEC61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Conducted interference EN61000-4-6/IEC61000-4-6 Criterion A; Test voltage 10 V
Noise emission test according to EN 61000-6-3
Radio interference properties EN 55022 Class B
Approvals
For the latest approvals, please visit phoenixcontact.net/products.

2688381

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules AXL DO 8/2-2A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet