FL-PP-RJ45... / FL CAT5...
104622_en_04 13
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
phoenixcontact.com
12 Shield grounding selection
With the following patch panels you can select the type of
shielding with a jumper:
FL-PP-RJ45-SCC
FL-PP-RJ45-SC
FL-PP-RJ45-LSA
FL-PP-RJ45/RJ45
By default upon delivery, the jumper is inserted and the
shield is positioned directly on the ground potential (PE).
With this arrangement, there is a low-ohmic electrical con-
nection between the shield and the ground potential.
If the jumper is removed, the shield is connected to the
ground potential via an RC combination. A high-ohmic resis-
tance parallel to a capacitor ensures that high-frequency
disturbances are delivered effectively to the ground poten-
tial without the presence of a low-ohmic electrical connec-
tion.
A single-sided grounding of the shield between two patch
panels is best suited for suppressing electrical fields and
ground loops.
Shield connection direct to PE (default setting)
Shield connection to PE via RC element
13 Circuit diagrams
Figure 15 FL-PP-RJ45-SCC (2901642)
FL-PP-RJ45-SC (2901643)
FL-PP-RJ45-LSA (2901645)
Figure 16 FL-PP-RJ45/RJ45 (2901646)
Figure 17 FL-PP-RJ45/RJ45-B (2904933)
Figure 18 FL CAT5 TERMINAL BOX (2744610)
With FL-PP-RJ45/RJ45-B, the shielding is not
connected with the DIN rail.
With FL CAT5 TERMINAL BOX, the shielding is
fundamentally connected to the DIN rail via the
universal snap-on foot.
1
Ø
1
Ø
1
Ø
1
Ø
RJ45
1
4
2
5
3
7
6
8
1 1nF
1
8
RJ45 RJ45
1 1nF
11
88
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
SS
RJ45
1
2
3
6
1
8

2901645

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Modular Connectors / Ethernet Connectors FL-PP-RJ45-LSA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet