FL-PP-RJ45... / FL CAT5...
104622_en_04 PHOENIX CONTACT 7
6 Patch panel FL-PP-RJ45-SCC with spring-cage connection terminal blocks
6.1 Design
1 RJ45 socket (TP port)
2 Spring-cage connection terminal blocks for field cabling
3 Strain relief with shield connection
4 Jumper for selecting shield grounding
5 Universal snap-on foot for DIN rails
6 DIN rail
6.2 Dimensions
Figure 1 Dimensions of FL-PP-RJ45-SCC
6.3 Connecting the Ethernet network
Twisted pair interface (TP port)
Take the Ethernet patch cable which leads to the termi-
nation device and has a RJ45 connector, and push this
into the RJ45 socket (TP port) until the connector audi-
bly snaps in.
Pin assignment and color coding
Figure 2 Ethernet (IEC 80.3u: TIA 568 A, TIA 568 B)
and PROFINET
YE = yellow
–OG = orange
–WH = white
–BU = blue
GN = green
–BN = brown
Spring-cage connection terminal blocks
Figure 3 Required stripping lengths
a = 10 mm
–b = 40 mm
–c = 8 mm
Remove cable sheath in accordance with length B.
Fold back 10 mm of the braided shield over the outer
sheath.
Remove the aluminum foil.
Shorten wires 4, 5, 7, and 8 by 10 mm as required for
the lower terminal block.
Strip 8 mm off each single wire.
Lay the shielding under the clip bracket of the strain re-
lief and screw tight.
Connect all single wires to the spring-cage connection
terminal blocks. If possible, make sure the single wires
remain twisted up to the connection terminal blocks.
Only use shielded twisted pair cables and corre-
sponding shielded RJ45 connectors.
3
4
1
2
5
6
12 3 6
4
578
1
Ø
89,6
59,8
52,3
29
12 36
4
5 7 8
BU6
WH3
OG2
YE1
1236
WH/BN7
GN6
BU4
WH/BU5
BN8
WH/GN3
OG2
WH/OG1
12364578
TIA 568 A
WH/BN7
OG6
BU4
WH/BU5
BN8
WH/OG3
GN2
WH/GN1
12364578
Ethernet
TIA 568 B
PROFINET
c
ab
FL-PP-RJ45... / FL CAT5...
104622_en_04 PHOENIX CONTACT 8
7 Patch panel FL-PP-RJ45-SC with screw connection terminal blocks
7.1 Design
1 RJ45 socket (TP port)
2 Screw connection terminal blocks for field cabling
3 Strain relief with shield connection
4 Jumper for selecting shield grounding
5 Universal snap-on foot for DIN rails
6 DIN rail
7.2 Dimensions
Figure 4 Dimensions of FL-PP-RJ45-SC
7.3 Connecting the Ethernet network
Twisted pair interface (TP port)
Take the Ethernet patch cable which leads to the termi-
nation device and has a RJ45 connector, and push this
into the RJ45 socket (TP port) until the connector audi-
bly snaps in.
Pin assignment and color coding
Figure 5 Ethernet (IEC 80.3u: TIA 568 A, TIA 568 B)
and PROFINET
YE = yellow
–OG = orange
–WH = white
–BU = blue
GN = green
–BN = brown
Screw connection terminal blocks
Figure 6 Required stripping lengths
a = 10 mm
–b = 35 mm
–c = 5 mm
Remove cable sheath in accordance with length B.
Fold back 10 mm of the braided shield over the outer
sheath.
Remove the aluminum foil.
Strip 5 mm off each single wire.
Lay the shielding under the clip bracket of the strain re-
lief and screw tight.
Connect the single wires to the screw terminal blocks. If
possible, make sure the single wires remain twisted up
to the connection terminal blocks.
Only use shielded twisted pair cables and corre-
sponding shielded RJ45 connectors.
3
4
1
2
5
6
1
Ø
14
25
37
6
8
89,6
59,8
52,3
29
BU6
WH3
OG2
YE1
1236
WH/BN7
GN6
BU4
WH/BU5
BN8
WH/GN3
OG2
WH/OG1
12364578
TIA 568 A
WH/BN7
OG6
BU4
WH/BU5
BN8
WH/OG3
GN2
WH/GN1
12364578
Ethernet
TIA 568 B
PROFINET
c
ab
FL-PP-RJ45... / FL CAT5...
104622_en_04 PHOENIX CONTACT 9
8 Patch panel FL-PP-RJ45-LSA with LSA connection terminal blocks
8.1 Design
1 RJ45 socket (TP port)
2 LSA connection terminal blocks for field cabling
3 Strain relief with shield connection
4 Jumper for selecting shield grounding
5 Universal snap-on foot for DIN rails
6 DIN rail
8.2 Dimensions
Figure 7 Dimensions of FL-PP-RJ45-LSA
8.3 Connecting the Ethernet network
Twisted pair interface (TP port)
Take the Ethernet patch cable which leads to the termi-
nation device and has a RJ45 connector, and push this
into the RJ45 socket (TP port) until the connector audi-
bly snaps in.
Pin assignment and color coding
Figure 8 Ethernet (IEC 80.3u: TIA 568 A, TIA 568 B)
and PROFINET
YE = yellow
–OG = orange
–WH = white
–BU = blue
GN = green
–BN = brown
LSA connection terminal blocks
Figure 9 Required stripping lengths
a = 10 mm
–b = 50 mm
Remove cable sheath in accordance with length B.
Fold back 10 mm of the braided shield over the outer
sheath.
Remove the aluminum foil.
Lay the shielding under the clip bracket of the strain re-
lief and screw tight.
Connect the wire pairs to the LSA terminal strip with the
help of the LSA connector punch tool. If possible, make
sure the single wires remain twisted up to the terminal
strips.
Make sure that the wires are flush with the terminal strip.
Only use shielded twisted pair cables and corre-
sponding shielded RJ45 connectors.
3
4
1
2
5
6
1
Ø
14
25
37
6
8
89,6
59,8
52,3
29
BU6
WH3
OG2
YE1
1236
WH/BN7
GN6
BU4
WH/BU5
BN8
WH/GN3
OG2
WH/OG1
12364578
TIA 568 A
WH/BN7
OG6
BU4
WH/BU5
BN8
WH/OG3
GN2
WH/GN1
12364578
Ethernet
TIA 568 B
PROFINET
ab

2901645

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Modular Connectors / Ethernet Connectors FL-PP-RJ45-LSA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet