ADM1033
http://onsemi.com
31
Table 52. REGISTER 0X10, REMOTE 1 THERM LIMIT, POWER-ON DEFAULT 0X95, LOCK = Y, S/W RESET = N
Bit Name R/W Description
<7:0> Remote 1 THERM
Limit
R/W When the Remote 1 temperature exceeds this temperature, the corresponding status bit
is set and the THERM output is activated.
Table 53. REGISTER 0X16, LOCAL OFFSET REGISTER, POWER-ON DEFAULT 0X00, LOCK = Y, S/W RESET = N
Bit Name R/W Description
<7:0> Local Offset R/W Allows a twos compliment offset to be automatically added to or subtracted from the
local temperature measurement. Resolution = 0.125C. Maximum offset from -16C to
+15.875C. Default = 0.
Table 54. REGISTER 0X17, REMOTE 1 OFFSET REGISTER, POWER-ON DEFAULT 0X00, LOCK = Y, S/W RESET = N
Bit Name R/W Description
<7:0> Remote 1 Offset R/W Allows a twos compliment offset to be automatically added to or subtracted from the
Remote 1 temperature measurement. Resolution = 0.125C. Maximum offset from
-16C to +15.875C. Default = 0.
Table 55. REGISTER 0X19, THERM TIMER % LIMIT, POWER-ON DEFAULT 0XFF, LOCK = Y, S/W RESET = N
Bit Name R/W Description
<7:0> THERM Timer on %
Limit
R/W If the THERM is asserted for greater than this limit on the time window, the
corresponding status bit is set.
Table 56. REGISTER 0X1A, THERM HYSTERESIS, POWER-ON DEFAULT 0X05, LOCK = Y, S/W RESET = N
Bit Name R/W Description
<7:4> Reserved R Reserved
<3:0> THERM Hysteresis R/W An unsigned THERM hysteresis value, LSB = 1C. Once THERM has been activated
on a temperature channel, the THERM
limit – hysteresis is deactivated if the
temperature drops below THERM.
ADM1033
http://onsemi.com
32
Table 57. LOOK-UP TABLE REGISTERS, LOCK = Y, S/W RESET = Y
Register Address R/W Description Power-On Default
0x22 R/W Look-up Table, T1 0xFF
0x23 R/W Look-up Table, T2 0xFF
0x24 R/W Look-up Table, T3 0xFF
0x25 R/W Look-up Table, T4 0xFF
0x26 R/W Look-up Table, T5 0xFF
0x27 R/W Look-up Table, T6 0xFF
0x28 R/W Look-up Table, T7 0xFF
0x29 R/W Look-up Table, T8 0xFF
0x2A R/W Look-up Table, FS1, LSB 0xFF
0x2B R/W Look-up Table, FS1, MSB 0xFF
0x2C R/W Look-up Table, FS2, LSB 0xFF
0x2D R/W Look-up Table, FS2, MSB 0xFF
0x2E R/W Look-up Table, FS3, LSB 0xFF
0x2F R/W Look-up Table, FS3, MSB 0xFF
0x30 R/W Look-up Table, FS4, LSB 0xFF
0x31 R/W Look-up Table, FS4, MSB 0xFF
0x32 R/W Look-up Table, FS5, LSB 0xFF
0x33 R/W Look-up Table, FS5, MSB 0xFF
0x34 R/W Look-up Table, FS6, LSB 0xFF
0x35 R/W Look-up Table, FS6, MSB 0xFF
0x36 R/W Look-up Table, FS7, LSB 0xFF
0x37 R/W Look-up Table, FS7, MSB 0xFF
0x38 R/W Look-up Table, FS8, LSB 0xFF
0x39 R/W Look-up Table, FS8, MSB 0xFF
Table 58. REGISTER 0X3A, LOOK-UP TABLE HYSTERESIS, POWER-ON DEFAULT 0X05, LOCK = Y, S/W RESET = Y
Bit Name R/W Description
<7:4> Reserved R Reserved
<3:0> Look-up Table Hysteresis R/W These bits determine the hysteresis applied to the temperature thresholds in the
Look-up table. LSB size = 1C.
Table 59. REGISTER 0X3C, FAN RESPONSE REGISTER, POWER-ON DEFAULT 0X01, LOCK = Y, S/W RESET = Y
Bit Name R/W Description
7 Res R Reserved
3 Res R Reserved
<2:0> Fan 1 Response R/W These bits set the fan’s response in the fan speed control mode.
000 = 1.25 updates/second
001 = 2.5 updates/second = Default
010 = 5 updates/second
011 = 10 updates/second
100 = 20 updates/second
101 = 40 updates/second
110 = 80 updates/second
111 = 160 updates/second
Table 60. REGISTER 0X3D, DEVICE ID, POWER-ON DEFAULT 0X34, LOCK = N, S/W RESET = N
Bit Name R/W Description
<7:0> Device ID R This read-only value contains the device ID, which is 0x34.
ADM1033
http://onsemi.com
33
Table 61. REGISTER 0X3E, COMPANY ID, POWER-ON DEFAULT 0X41, LOCK = N, S/W RESET = N
Bit Name R/W Description
<7:0> Company ID R This read-only value contains the company ID, which is 0x41.
Table 62. REGISTER 0X3F, REVISION REGISTER, POWER-ON DEFAULT 0X02, LOCK = N, S/W RESET = N
Bit Name R/W Description
<7:0> Revision ID R This read-only value contains the revision ID.
Table 63. REGISTER 0X40/41, LOCAL TEMP REGISTERS, POWER-ON DEFAULT 0X00, LOCK = N, S/W RESET = Y
Bit Name R/W Description
<4:0> Local Temperature LSB R This register contains the LSBs of the last measured local temperature value.
Resolution = 0.03125C.
<12:5> Local Temperature MSB R This register contains the MSBs of the last measured local temperature value.
Resolution = 1C.
Table 64. REGISTER 0X42/43, REMOTE 1 TEMP REGISTERS, POWER-ON DEFAULT 0X00, LOCK = N, S/W RESET = Y
Bit Name R/W Description
<4:0> Remote 1 Temperature LSB R This register contains the LSBs of the last measured Remote 1 temperature
value. Resolution = 0.03125C.
<12:5> Remote 1 Temperature MSB R This register contains the LSBs of the last measured Remote 1 temperature
value. Resolution = 1C.
Table 65. REGISTER 0X4A/4B, TACH1 PERIOD, POWER-ON DEFAULT 0XFF, LOCK = N, S/W RESET = Y
Bit Name R/W Description
<7:0> Fan 1 Period Count, LSB R This register contains the LSBs of the last measured Fan 1 revolution count.
<15:8> Fan 1 Period Count, MSB R This register contains the MSBs of the last measured Fan 1 revolution count.
Table 66. REGISTER 0X4E, THERM % ON-TIME, POWER-ON DEFAULT 0X00, LOCK = N, S/W RESET = Y
Bit Name R/W Description
<7:0> THERM % On-Time R Represents the % time of THERM activity within the time window set by the
configuration bits.
Table 67. REGISTER 0X4F, STATUS 1, POWER-ON DEFAULT 0X00, LOCK = N, S/W RESET = Y
Bit Name R/W Description
7 Local Temp High R A 1 indicates that the local high limit has been tripped.
6 Local Temp Low R A 1 indicates that the local low limit has been tripped.
5 Remote 1 Temp High R A 1 indicates that the Remote 1 high limit has been tripped.
4 Remote 1 Temp Low R A 1 indicates that the Remote 1 low limit has been tripped.
3 Remote 1 Diode Error R A 1 indicates that a short or an open has been detected on the Remote 1
temperature channel. This test is completed once on each conversion.