ELR H3-IES-PT- 24DC/500AC-...
105518_en_01 PHOENIX CONTACT 13
9.2 Safety door (emergency stop)
In applications where safety shutdown is a normal operating
state,e.g., for safety door or two-hand applications, it is the
control circuit that is switched and not the control supply
voltage.
Figure 5 Safety door (emergency stop)
1 Supply 1
2 Supply 2
3 Emergency stop
4 Reset button
If shutdown is performed, e.g.,from a “safe controller” with
semiconductor outputs, the residual voltage must be <
5VDC.
Interruptions 3ms are filtered.
U1
V1
W1
PE
M
3
S2
S2
S3
F1
L1
L2
L3
N
PE
24VDC
GND
97
2/
T1
4/
T2
6/
T3
ON
1/
L1
3/
L2
5/
L3
ELR-H3-.../500AC-...
24VDC
GND
96/98
95
RES
MAN
AUT
U
S
E
S11
S12
S21
S22
13
23
41
14
24
42
A2
A1
PSR-SCP-24UC/ESA4/3X1/1X2/B
S33
S34
33
34
1
2
3
4
ELR H3-IES-PT- 24DC/500AC-...
105518_en_01 PHOENIX CONTACT 14
9.3 Motor protection
All safety-related functions are implemented by the hybrid
motor starter without external influences. Special circuit
technology is not required.
The wiring of the load circuit should be implemented as de-
scribed in the examples.
However, the module power supply can be connected di-
rectly to the voltage source, without the PSR safety relay.
The same applies for the control.
The motor currents are measured at phases L1 and L3 and
monitored for symmetry.
In the event of a deviation of 33%, the motor shuts down
after 2minutes.
In the event of a deviation of 67% (e.g.,phase failure), the
motor shuts down after 1.8seconds.
The deviation can be calculated using the following formu-
las.
Value I
max
> I
nom
(I
max
- I
min
)/I
max
Value I
max
< I
nom
(I
max
- I
min
)/I
nom
9.4 Motor with brake
If a motor with brake (connection in the motor terminal
board) is connected, the 400VAC brake must be linked to
the 2/T1 and 6/T3 terminals. A 230VAC brake must be con-
nected to the 4/T2 terminals and the star point of the motor.
9.5 Auxiliary relay connection
Auxiliary relay (e.g. PLC RSC 230UC/21, order no.:
2966207) for activating external brakes or acknowledge-
ments, e.g. to the PLC, must be connected to the 4T2 and
N connections of the system.
NOTE
Increase motor current monitoring to the nom-
inal brake current. This should be set accord-
ingly on the hybrid motor starter.
ELR H3-IES-PT- 24DC/500AC-...
105518_en_01 PHOENIX CONTACT 15
10 Safety functions
10.1 Safe shutdown
10.2 Motor protection
System conditions
Database for failure rates SN29500
System type (consisting of subsystems) Type B
Standard used IEC61508
Beta factor 1%
MTTF [years] (mean time to failure at
ambient temperature of40°C)
43.0
Ambient temperature 40°C
MTTFd [years] - mean time to dan-
gerous failure
518
Shutdown time [ms] 80
sd [FIT] - safe, detectable 543
su [FIT] - safe, undetectable 852
dd [FIT] - dangerous, detectable 218
du [FIT] - dangerous, undetectable 2.4
SFF [%] - safe failure fraction 99.9
DCS [%] - diagnostic coverage safe 38.9
DC [%] - diagnostic coverage 99
PFH - probability of failure per hour 2.4 x 10
-9
Safety level according to IEC/CEI 61508-1: SIL 3
ISO 13849-1: category 3 PL e
EN 954-1: category 3
Ambient temperature 40°C
MTTFd [years] - mean time to dan-
gerous failure
447
Shutdown time [ms] According to Class 10A, IEC/CEI 60947
sd [FIT] - safe, detectable 517
su [FIT] - safe, undetectable 809
dd [FIT] - dangerous, detectable 239
du [FIT] - dangerous, undetectable 17
SFF [%] - safe failure fraction 99
DCS [%] - diagnostic coverage safe 39.0
DC [%] - diagnostic coverage 93.3
Safety level according to IEC/CEI 61508-1: SIL 2
Additional safety data is available on request.

2903914

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules ELR H3-IES-PT- 24DC/ 500AC-0.6
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: