CY7C1410AV18
CY7C1425AV18
CY7C1412AV18
CY7C1414AV18
Document #: 38-05615 Rev. *C Page 10 of 25
L H L-H During the Data portion of a Write sequence:
CY7C1410AV18 only the lower nibble (D
[3:0]
) is written into the device. D
[7:4]
will
remain unaltered,
CY7C1412AV18 only the lower byte (D
[8:0]
) is written into the device. D
[17:9]
will
remain unaltered.
H L L-H During the Data portion of a Write sequence:
CY7C1410AV18 only the upper nibble (D
[7:4]
) is written into the device. D
[3:0]
will
remain unaltered,
CY7C1412AV18 only the upper byte (D
[17:9]
) is written into the device. D
[8:0]
will
remain unaltered.
H L L-H During the Data portion of a Write sequence:
CY7C1410AV18 only the upper nibble (D
[7:4]
) is written into the device. D
[3:0]
will
remain unaltered,
CY7C1412AV18 only the upper byte (D
[17:9]
) is written into the device. D
[8:0]
will
remain unaltered.
H H L-H No data is written into the devices during this portion of a Write operation.
H H L-H No data is written into the devices during this portion of a Write operation.
Write Cycle Descriptions
(CY7C1414AV18)
[2, 8]
BWS
0
BWS
1
BWS
2
BWS
3
KK Comments
L L L L L-H During the Data portion of a Write sequence, all four bytes (D
[35:0]
) are
written into the device.
L L L L L-H During the Data portion of a Write sequence, all four bytes (D
[35:0]
) are
written into the device.
L H H H L-H During the Data portion of a Write sequence, only the lower byte (D
[8:0]
)
is written into the device. D
[35:9]
will remain unaltered.
L H H H L-H During the Data portion of a Write sequence, only the lower byte (D
[8:0]
)
is written into the device. D
[35:9]
will remain unaltered.
H L H H L-H During the Data portion of a Write sequence, only the byte (D
[17:9]
) is
written into the device. D
[8:0]
and D
[35:18]
will remain unaltered.
H L H H L-H During the Data portion of a Write sequence, only the byte (D
[17:9]
) is
written into the device. D
[8:0]
and D
[35:18]
will remain unaltered.
H H L H L-H During the Data portion of a Write sequence, only the byte (D
[26:18]
) is
written into the device. D
[17:0]
and D
[35:27]
will remain unaltered.
H H L H L-H During the Data portion of a Write sequence, only the byte (D
[26:18]
) is
written into the device. D
[17:0]
and D
[35:27]
will remain unaltered.
H H H L L-H During the Data portion of a Write sequence, only the byte (D
[35:27]
) is
written into the device. D
[26:0]
will remain unaltered.
H H H L L-H During the Data portion of a Write sequence, only the byte (D
[35:27]
) is
written into the device. D
[26:0]
will remain unaltered.
H H H H L-H No data is written into the device during this portion of a Write operation.
H H H H L-H No data is written into the device during this portion of a Write operation.
Write Cycle Descriptions
(CY7C1425AV18)
BWS
0
KK Comments
L L-H During the Data portion of a Write sequence:
CY7C1425AV18 - the single byte (D[8:0]) is written into the device
L L-H During the Data portion of a Write sequence:
CY7C1425AV18 - the single byte (D[8:0]) is written into the device
H L-H No data is written into the devices during this portion of a Write operation.
H L-H No data is written into the devices during this portion of a Write operation.
Write Cycle Descriptions
(CY7C1410AV18 and CY7C1412AV18) (continued)
[2, 8]
BWS
0
/
NWS
0
BWS
1
/
NWS
1
KK
Comments
[+] Feedback
CY7C1410AV18
CY7C1425AV18
CY7C1412AV18
CY7C1414AV18
Document #: 38-05615 Rev. *C Page 11 of 25
IEEE 1149.1 Serial Boundary Scan (JTAG)
These SRAMs incorporate a serial boundary scan test access
port (TAP) in the FBGA package. This part is fully compliant
with IEEE Standard #1149.1-1900. The TAP operates using
JEDEC standard 1.8V I/O logic levels.
Disabling the JTAG Feature
It is possible to operate the SRAM without using the JTAG
feature. To disable the TAP controller, TCK must be tied LOW
(V
SS
) to prevent clocking of the device. TDI and TMS are inter-
nally pulled up and may be unconnected. They may alternately
be connected to V
DD
through a pull-up resistor. TDO should
be left unconnected. Upon power-up, the device will come up
in a reset state which will not interfere with the operation of the
device.
Test Access Port—Test Clock
The test clock is used only with the TAP controller. All inputs
are captured on the rising edge of TCK. All outputs are driven
from the falling edge of TCK.
Test Mode Select
The TMS input is used to give commands to the TAP controller
and is sampled on the rising edge of TCK. It is allowable to
leave this pin unconnected if the TAP is not used. The pin is
pulled up internally, resulting in a logic HIGH level.
Test Data-In (TDI)
The TDI pin is used to serially input information into the
registers and can be connected to the input of any of the
registers. The register between TDI and TDO is chosen by the
instruction that is loaded into the TAP instruction register. For
information on loading the instruction register, see the TAP
Controller State Diagram. TDI is internally pulled up and can
be unconnected if the TAP is unused in an application. TDI is
connected to the most significant bit (MSB) on any register.
Test Data-Out (TDO)
The TDO output pin is used to serially clock data-out from the
registers. The output is active depending upon the current
state of the TAP state machine (see Instruction codes). The
output changes on the falling edge of TCK. TDO is connected
to the least significant bit (LSB) of any register.
Performing a TAP Reset
A Reset is performed by forcing TMS HIGH (VDD) for five
rising edges of TCK. This RESET does not affect the operation
of the SRAM and may be performed while the SRAM is
operating. At power-up, the TAP is reset internally to ensure
that TDO comes up in a high-Z state.
TAP Registers
Registers are connected between the TDI and TDO pins and
allow data to be scanned into and out of the SRAM test
circuitry. Only one register can be selected at a time through
the instruction registers. Data is serially loaded into the TDI pin
on the rising edge of TCK. Data is output on the TDO pin on
the falling edge of TCK.
Instruction Register
Three-bit instructions can be serially loaded into the instruction
register. This register is loaded when it is placed between the
TDI and TDO pins as shown in TAP Controller Block Diagram.
Upon power-up, the instruction register is loaded with the
IDCODE instruction. It is also loaded with the IDCODE
instruction if the controller is placed in a reset state as
described in the previous section.
When the TAP controller is in the Capture IR state, the two
least significant bits are loaded with a binary “01” pattern to
allow for fault isolation of the board level serial test path.
Bypass Register
To save time when serially shifting data through registers, it is
sometimes advantageous to skip certain chips. The bypass
register is a single-bit register that can be placed between TDI
and TDO pins. This allows data to be shifted through the
SRAM with minimal delay. The bypass register is set LOW
(V
SS
) when the BYPASS instruction is executed.
Boundary Scan Register
The boundary scan register is connected to all of the input and
output pins on the SRAM. Several no connect (NC) pins are
also included in the scan register to reserve pins for higher
density devices.
The boundary scan register is loaded with the contents of the
RAM Input and Output ring when the TAP controller is in the
Capture-DR state and is then placed between the TDI and
TDO pins when the controller is moved to the Shift-DR state.
The EXTEST, SAMPLE/PRELOAD and SAMPLE Z instruc-
tions can be used to capture the contents of the Input and
Output ring.
The Boundary Scan Order tables show the order in which the
bits are connected. Each bit corresponds to one of the bumps
on the SRAM package. The MSB of the register is connected
to TDI, and the LSB is connected to TDO.
Identification (ID) Register
The ID register is loaded with a vendor-specific, 32-bit code
during the Capture-DR state when the IDCODE command is
loaded in the instruction register. The IDCODE is hardwired
into the SRAM and can be shifted out when the TAP controller
is in the Shift-DR state. The ID register has a vendor code and
other information described in the Identification Register
Definitions table.
TAP Instruction Set
Eight different instructions are possible with the three-bit
instruction register. All combinations are listed in the
Instruction Code table. Three of these instructions are listed
as RESERVED and should not be used. The other five instruc-
tions are described in detail below.
Instructions are loaded into the TAP controller during the
Shift-IR state when the instruction register is placed between
TDI and TDO. During this state, instructions are shifted
through the instruction register through the TDI and TDO pins.
To execute the instruction once it is shifted in, the TAP
controller needs to be moved into the Update-IR state.
IDCODE
The IDCODE instruction causes a vendor-specific, 32-bit code
to be loaded into the instruction register. It also places the
instruction register between the TDI and TDO pins and allows
the IDCODE to be shifted out of the device when the TAP
controller enters the Shift-DR state. The IDCODE instruction
[+] Feedback
CY7C1410AV18
CY7C1425AV18
CY7C1412AV18
CY7C1414AV18
Document #: 38-05615 Rev. *C Page 12 of 25
is loaded into the instruction register upon power-up or
whenever the TAP controller is given a test logic reset state.
SAMPLE Z
The SAMPLE Z instruction causes the boundary scan register
to be connected between the TDI and TDO pins when the TAP
controller is in a Shift-DR state. The SAMPLE Z command puts
the output bus into a High-Z state until the next command is
given during the “Update IR” state.
SAMPLE/PRELOAD
SAMPLE/PRELOAD is a 1149.1 mandatory instruction. When
the SAMPLE/PRELOAD instructions are loaded into the
instruction register and the TAP controller is in the Capture-DR
state, a snapshot of data on the inputs and output pins is
captured in the boundary scan register.
The user must be aware that the TAP controller clock can only
operate at a frequency up to 20 MHz, while the SRAM clock
operates more than an order of magnitude faster. Because
there is a large difference in the clock frequencies, it is
possible that during the Capture-DR state, an input or output
will undergo a transition. The TAP may then try to capture a
signal while in transition (metastable state). This will not harm
the device, but there is no guarantee as to the value that will
be captured. Repeatable results may not be possible.
To guarantee that the boundary scan register will capture the
correct value of a signal, the SRAM signal must be stabilized
long enough to meet the TAP controller's capture set-up plus
hold times (t
CS
and t
CH
). The SRAM clock input might not be
captured correctly if there is no way in a design to stop (or
slow) the clock during a SAMPLE/PRELOAD instruction. If this
is an issue, it is still possible to capture all other signals and
simply ignore the value of the CK and CK captured in the
boundary scan register.
Once the data is captured, it is possible to shift out the data by
putting the TAP into the Shift-DR state. This places the
boundary scan register between the TDI and TDO pins.
PRELOAD allows an initial data pattern to be placed at the
latched parallel outputs of the boundary scan register cells
prior to the selection of another boundary scan test operation.
The shifting of data for the SAMPLE and PRELOAD phases
can occur concurrently when required—that is, while data
captured is shifted out, the preloaded data can be shifted in.
BYPASS
When the BYPASS instruction is loaded in the instruction
register and the TAP is placed in a Shift-DR state, the bypass
register is placed between the TDI and TDO pins. The
advantage of the BYPASS instruction is that it shortens the
boundary scan path when multiple devices are connected
together on a board.
EXTEST
The EXTEST instruction enables the preloaded data to be
driven out through the system output pins. This instruction also
selects the boundary scan register to be connected for serial
access between the TDI and TDO in the shift-DR controller
state.
EXTEST OUTPUT BUS TRI-STATE
IEEE Standard 1149.1 mandates that the TAP controller be
able to put the output bus into a tri-state mode.
The boundary scan register has a special bit located at bit
#108. When this scan cell, called the “extest output bus
tri-state,” is latched into the preload register during the
“Update-DR” state in the TAP controller, it will directly control
the state of the output (Q-bus) pins, when the EXTEST is
entered as the current instruction. When HIGH, it will enable
the output buffers to drive the output bus. When LOW, this bit
will place the output bus into a High-Z condition.
This bit can be set by entering the SAMPLE/PRELOAD or
EXTEST command, and then shifting the desired bit into that
cell, during the “Shift-DR” state. During “Update-DR”, the value
loaded into that shift-register cell will latch into the preload
register. When the EXTEST instruction is entered, this bit will
directly control the output Q-bus pins. Note that this bit is
pre-set LOW to enable the output when the device is
powered-up, and also when the TAP controller is in the
“Test-Logic-Reset” state.
Reserved
These instructions are not implemented but are reserved for
future use. Do not use these instructions.