4
ECL Pro®
SY100EP196V
Micrel
M0644-012704
Absolute Maximum Ratings
(1)
Supply Voltage (V
CC
)
PECL Mode (V
EE
=0V)............................. –0.5V to +6.0V
Supply Voltage (V
EE
)
NECL Mode (V
CC
=0V) ............................ +0.5V to –6.0V
Any Input Voltage (V
IN
)
PECL Mode .......................................–0.5V to V
CC
+0.5V
NECL Mode....................................... +0.5V to V
EE
–0.5V
ECL Output Current (I
OUT
)
Continuous .............................................................50mA
Surge....................................................................100mA
I
BB
Sink/Source Current ..........................................±0.5mA
Lead Temperature (soldering, 10 sec.) ................... +300°C
Storage Temperature (T
S
) ....................... –65°C to +150°C
ESD Rating
(3)
...........................................................>1.5kV
Operating Ratings
(2)
Supply Voltage (V
CC
)
PECL Mode (V
EE
=0V)............................. +3.0V to +5.5V
Supply Voltage (V
EE
)
NECL Mode (V
CC
=0V) ............................ –3.0V to –5.5V
Ambient Temperature (T
A
) ......................... –40°C to +85°C
Package Thermal Resistance
TQFP-32 (θ
JA
)
Still-air .............................................................50°C/W
500lfpm............................................................42°C/W
TQFP-32 (θ
JC
).....................................................20°C/W
T
A
= –40°C to +85°C
Symbol Parameter Condition Min Typ Max Units
V
CC
Power Supply Voltage (PECL) 3.0 3.3 3.6 V
4.5 5.0 5.5 V
V
EE
Power Supply Voltage (NECL) –3.6 –3.3 –3.0 V
–5.5 –5.0 –4.5 V
I
EE
Power Supply Current
(4)
No Load, Over Supply Voltage 150 175 mA
Notes:
1. Permanent device damage may occur if
“Absolute Maximum Ratings”
are exceeded. This is a stress rating only and functional operation is not
implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to
“Absolute Maximum Rating”
conditions for
extended periods may affect device reliability.
2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
3. Devices are ESD sensitive. Handling precautions recommended.
4. Required 500lfpm air flow when using +5V or –5V power supply.
DC ELECTRICAL CHARACTERISTICS