Automotive PSoC
®
4: PSoC 4100
Family Datasheet
Document Number: 001-93576 Rev. *E Page 22 of 36
SPI Specifications
Table 22. Fixed SPI DC Specifications (Guaranteed by Characterization)
Spec ID Parameter Description Min Typ Max Units
SID163 I
SPI1
Block current consumption at 1 Mbits/sec 360 µA
SID164 I
SPI2
Block current consumption at 4 Mbits/sec 560 µA
SID165 I
SPI3
Block current consumption at 8 Mbits/sec 600 µA
Table 23. Fixed SPI AC Specifications (Guaranteed by Characterization)
Spec ID Parameter Description Min Typ Max Units
SID166 F
SPI
SPI operating frequency (master; 6X
oversampling)
–– 4MHz
Table 24. Fixed SPI Master mode AC Specifications (Guaranteed by Characterization)
Spec ID Parameter Description Min Typ Max Units
SID167 T
DMO
MOSI valid after Sclock driving edge 15 ns
SID168 T
DSI
MISO valid before Sclock capturing edge. Full
clock, late MISO Sampling used
20 ns
SID169 T
HMO
Previous MOSI data hold time with respect to
capturing edge at Slave
0– ns
Table 25. Fixed SPI Slave mode AC Specifications (Guaranteed by Characterization)
Spec ID Parameter Description Min Typ Max Units
SID170 T
DMI
MOSI valid before Sclock capturing edge 40 ns
SID171 T
DSO
MISO valid after Sclock driving edge 42 + (3 ×
Tscbclk)
ns
SID171A T
DSO_ext
MISO valid after Sclock driving edge in Ext.
Clock mode
48 ns
SID172 T
HSO
Previous MISO data hold time 0 ns
SID172A T
SSELSCK
SSEL Valid to first SCK Valid edge 100 ns
Automotive PSoC
®
4: PSoC 4100
Family Datasheet
Document Number: 001-93576 Rev. *E Page 23 of 36
Memory
System Resources
Power-on-Reset (POR) with Brown Out
Table 26. Flash DC Specifications
Spec ID Parameter Description Min Typ Max Units Details/Conditions
SID173 V
PE
Erase and program voltage 1.71 5.5 V
Table 27. Flash AC Specifications
Spec ID Parameter Description Min Typ Max Units Details/Conditions
SID174 T
ROWWRITE
[3]
Row (block) write time (erase and
program)
20 ms Row (block) = 128 bytes. –40
°C
T
A
85 °C
26 ms Row (block) = 128 bytes. –40
°C
T
A
105 °C
SID175 T
ROWERASE
[3]
Row erase time 13 ms
SID176 T
ROWPROGRAM
[3]
Row program time after erase 7 ms –40 °C T
A
85 °C
13 ms –40 °C
T
A
105 °C
SID178 T
BULKERASE
[3]
Bulk erase time (32 KB) 35 ms
SID180 T
DEVPROG
[3]
Total device program time 7 seconds Guaranteed by characterization
SID181 F
END
Flash endurance 100 K cycles Guaranteed by characterization
SID182 F
RET
Flash retention. T
A
55 °C, 100 K
P/E cycles
20 years Guaranteed by characterization
SID182A Flash retention. T
A
85 °C, 10 K
P/E cycles
10 years Guaranteed by characterization
SID182B F
RETQ
Flash retention. T
A
105 °C,
10K P/E cycles, <
three years at
T
A
> 85 °C.
10 20 Guaranteed by character-
ization.
Table 28. Imprecise Power On Reset (PRES)
Spec ID Parameter Description Min Typ Max Units Details/Conditions
SID185 V
RISEIPOR
Rising trip voltage 0.80 1.45 V Guaranteed by characterization
SID186 V
FALLIPOR
Falling trip voltage 0.75 1.4 V Guaranteed by characterization
SID187 V
IPORHYST
Hysteresis 15 200 mV Guaranteed by characterization
Table 29. Precise Power On Reset (POR)
Spec ID Parameter Description Min Typ Max Units Details/Conditions
SID190 V
FALLPPOR
BOD trip voltage in active and
sleep modes
1.64 V Full functionality between 1.71 V
and BOD trip voltage is
guaranteed by characterization
SID192 V
FALLDPSLP
BOD trip voltage in Deep Sleep 1.4 V Guaranteed by characterization
BID55 Svdd Maximum power supply ramp
rate
––67kV/sec
Note
3. It can take as much as 20 milliseconds to write to Flash. During this time the device should not be Reset, or Flash operations will be interrupted and cannot be relied
on to have completed. Reset sources include the XRES pin, software resets, CPU lockup states and privilege violations, improper power supply levels, and watchdogs.
Make certain that these are not inadvertently activated.
Automotive PSoC
®
4: PSoC 4100
Family Datasheet
Document Number: 001-93576 Rev. *E Page 24 of 36
Voltage Monitors
SWD Interface
Table 30. Voltage Monitors DC Specifications
Spec ID Parameter Description Min Typ Max Units Details/Conditions
SID195 V
LVI1
LVI_A/D_SEL[3:0] = 0000b 1.71 1.75 1.79 V
SID196 V
LVI2
LVI_A/D_SEL[3:0] = 0001b 1.76 1.80 1.85 V
SID197 V
LVI3
LVI_A/D_SEL[3:0] = 0010b 1.85 1.90 1.95 V
SID198 V
LVI4
LVI_A/D_SEL[3:0] = 0011b 1.95 2.00 2.05 V
SID199 V
LVI5
LVI_A/D_SEL[3:0] = 0100b 2.05 2.10 2.15 V
SID200 V
LVI6
LVI_A/D_SEL[3:0] = 0101b 2.15 2.20 2.26 V
SID201 V
LVI7
LVI_A/D_SEL[3:0] = 0110b 2.24 2.30 2.36 V
SID202 V
LVI8
LVI_A/D_SEL[3:0] = 0111b 2.34 2.40 2.46 V
SID203 V
LVI9
LVI_A/D_SEL[3:0] = 1000b 2.44 2.50 2.56 V
SID204 V
LVI10
LVI_A/D_SEL[3:0] = 1001b 2.54 2.60 2.67 V
SID205 V
LVI11
LVI_A/D_SEL[3:0] = 1010b 2.63 2.70 2.77 V
SID206 V
LVI12
LVI_A/D_SEL[3:0] = 1011b 2.73 2.80 2.87 V
SID207 V
LVI13
LVI_A/D_SEL[3:0] = 1100b 2.83 2.90 2.97 V
SID208 V
LVI14
LVI_A/D_SEL[3:0] = 1101b 2.93 3.00 3.08 V
SID209 V
LVI15
LVI_A/D_SEL[3:0] = 1110b 3.12 3.20 3.28 V
SID210 V
LVI16
LVI_A/D_SEL[3:0] = 1111b 4.39 4.50 4.61 V
SID211 LVI_IDD Block current 100 µA Guaranteed by
characterization
Table 31. Voltage Monitors AC Specifications
Spec ID Parameter Description Min Typ Max Units Details/Conditions
SID212 T
MONTRIP
Voltage monitor trip time 1 µs Guaranteed by
characterization
Table 32. SWD Interface Specifications
Spec ID Parameter Description Min Typ Max Units Details/Conditions
SID213 F_SWDCLK1 3.3 V V
DD
5.5 V 14 MHz SWDCLK 1/3 CPU
clock frequency
SID214 F_SWDCLK2 1.71 V
V
DD
3.3 V 7 MHz SWDCLK 1/3 CPU
clock frequency
SID215 T_SWDI_SETUP T = 1/f SWDCLK 0.25*T ns Guaranteed by
characterization
SID216 T_SWDI_HOLD T = 1/f SWDCLK 0.25*T ns Guaranteed by
characterization
SID217 T_SWDO_VALID T = 1/f SWDCLK 0.5*T ns Guaranteed by
characterization
SID217A T_SWDO_HOLD T = 1/f SWDCLK 1 ns Guaranteed by
characterization

CY8C4125PVA-482

Mfr. #:
Manufacturer:
Cypress Semiconductor
Description:
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: