KMA200 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved.
Product data sheet Rev. 8 — 7 December 2011 10 of 33
NXP Semiconductors
KMA200
Programmable angle sensor
Fig 5. Half range output mode (mode 2)
Fig 6. Comparator analog output (mode 3)
006aaa300
0° 180°
α
max
100 %
50 %
V
(CL)u
/2
V
(CL)l
/2
2 %
0
V
OUT2
/V
DD
diagnostics area
diagnostics area
(180° − α
max
)/2
KMA200 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved.
Product data sheet Rev. 8 — 7 December 2011 11 of 33
NXP Semiconductors
KMA200
Programmable angle sensor
8. Digital output (SPI)
Standard digital output
If the standard digital output mode is configured, output data can be read with the serial
interface. Figure 7
shows the timing diagram of an interface access. The access is
enclosed by a HIGH-to-LOW and LOW-to-HIGH transition of CS
.
DATA are clocked out at the falling edge of CLK and should be evaluated at the rising
edge. The output data consist of 3 bytes (24 bits). The first two data bytes contain an error
flag and 13 bits of angle information. The last data byte contains the measured
temperature as 7-bit value. Every byte features a parity bit (odd parity).
The data transmission can be interrupted at any time by deactivating CS
. If, for instance,
the temperature information is not desired, the data transfer can be finished by
deactivating CS
after reading the first two data bytes.
If the error flag is 0, the 13 angle data bits contain the most significant bits of the
calculated angle. If the error flag is 1, an error condition was detected. The two least
significant angle data bits (A[1:0]) are replaced by an error code. All other angle data bits
(A[12:2]) still show the current measurement value. Depending on the special error case,
the measurement values are reliable or not. Error codes are described in Table 8
.
The output driver of the DATA pin is slew-rate limited. The rise and fall times of the DATA
output can be programmed with the SL bit (ctrl EEPROM constant); see Table 12
.
Complementary digital output
In complementary digital output mode the data transmitted is identical to the output data in
standard digital output mode except that the angle and temperature information data bits
are logically inverted. The error flag and the error code in bits A[1:0] when the error flag is
set are coded as in case of standard digital output. The parity bits also use odd parity as
standard digital output mode.
Fig 7. Digital output coding
006aaa302
CS
CLK
DATA
angle (MSBs) angle (LSBs) temperature
DATA HIGH-Z (HIGH by internal weak pullup)
Parity bits (odd parity)
Error flag
13-bit angle data
7-bit temperature data
P2, P1, P0
EF
A12 to A0
T6 to T0
P2 A12 A11EF A7 A6 A5P1 A0 T6 T5P0 T0
KMA200 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved.
Product data sheet Rev. 8 — 7 December 2011 12 of 33
NXP Semiconductors
KMA200
Programmable angle sensor
9. Limiting values
Table 6. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol Parameter Conditions Min Max Unit
V
DD
supply voltage pin V
DD
versus GND 16.5 +26.5 V
at t < 400 ms - 32 V
V
X
voltage on pins CS, DATA/OUT1, CLK/OUT2
versus GND
0100%V
DD
T
amb
ambient temperature < 1000 hours in life time at 160 C 40 +160 C
T
amb(pr)
programming ambient temperature EEPROM 10 70 C
T
stg
storage temperature 50 +150 C
EEPROM
t
ret
retention time T
max(AV)
=50C17-year
N
endu(W_ER)
write or erase endurance T
max(AV)
=70C for programming - 500 cycle