AMIS−49587
www.onsemi.com
4
2 ABSOLUTE MAXIMUM RATINGS2.1
Stresses above those listed in this clause may cause permanent device failure. Exposure to absolute maximum ratings for
extended periods may affect device reliability.
2.1.1 Power Supply Pins VDD, VDDA, VSS, VSSA
Table 2. ABSOLUTE MAXIMUM RATINGS SUPPLY
Rating Symbol Min Max Unit
Absolute maximum digital power supply V
DD_ABSM
V
SS
−0.3 3.9 V
Absolute maximum analog power supply V
DDA_ABSM
V
SSA
−0.3 3.9 V
Absolute maximum difference between digital and analog power supply V
DD
−V
DDA_ABSM
−0.3 0.3 V
Absolute maximum difference between digital and analog ground V
SS
−V
SSA_ABSM
−0.3 0.3 V
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
2.1.2 Non 5V Safe Pins: TX_OUT, ALC_IN, RX_IN, RX_OUT, REF_OUT, M50HZ_IN, XIN, XOUT, TDO, TDI, TCK, TMS,
TRSTB, TEST
Table 3. ABSOLUTE MAXIMUM RATINGS NON 5V SAFE PINS
Rating Symbol Min Max Unit
Absolute maximum input for normal digital inputs and analog inputs V
IN_ABSM
V
SS*
−0.3 V
DD*
+0.3 V
Absolute maximum voltage at any output pin V
OUT_ABSM
V
SS*
−0.3 V
DD*
+0.3 V
2.1.3 5V Safe Pins: TX_ENB, TXD, RXD, BR0, BR1, RESB, RX_DATA, TREQ, CRC, TX_DATA/PRE_SLOT
Table 4. ABSOLUTE MAXIMUM RATINGS 5V SAFE PINS
Rating Symbol Min Max Unit
Absolute maximum input for digital 5 V safe inputs V
5VS_ABSM
V
SS
−0.3 6.0 V
Absolute maximum voltage at 5 V safe output pin V
OUT5V_ABSM
V
SS
−0.3 3.9 V
2.2 Normal Operating Conditions
Operating ranges define the limits for functional operation and parametric characteristics of the device as described in the
Receiver Block Diagram Section and for the reliability specifications as listed in the Local Transfer and Configuration
Commands (LTC) Section. Functionality outside these limits is not implied.
Total cumulative dwell time outside the normal power supply voltage range or the ambient temperature under bias, must be
less than 0.1% of the useful life as defined in the Local Transfer and Configuration Commands (LTC) Section.
Table 5. OPERATING RANGES
Rating Symbol Min Max Unit
Power Supply Voltage Range V
DD
3.0 3.6 V
Ambient Temperature T
A
−25 85 °C