Notes: 1. I/O5 switches to a “1” when a program or an erase operation has exceeded the maximum time limits or when a program or
sector erase operation is performed on a protected sector.
2. I/O3 switches to a “1” when the V
PP
level is not high enough to successfully perform program and erase operations.
4. Status Bit Table
Status Bit
I/O7 I/O7 I/O6 I/O5
(1)
I/O3
(2)
I/O2
Configuration Register 00 01 00/01 00/01 00/01 00/01
Programming
I/O7 0 TOGGLE 0 0 1
Erasing 0 0 TOGGLE 0 0 TOGGLE
Erase Suspended & Read
Erasing Sector
1 1 1 0 0 TOGGLE
Erase Suspended & Read
Non-erasing Sector
DATA DATA DATA DATA DATA DATA
Erase Suspended & Program
Non-erasing Sector
I/O7 0 TOGGLE 0 0 TOGGLE
Erase Suspended & Program
Suspended and Reading from
Non-suspended Sectors
DATA DATA DATA DATA DATA DATA
Program Suspended & Read
Programming Sector
I/O7 1 1 0 0 TOGGLE
Program Suspended & Read
Non-programming Sector
DATA DATA DATA DATA DATA DATA
11
3631A–FLASH–04/06
AT49BV642D(T)
Notes: 1. The DATA FORMAT in each bus cycle is as follows: I/O15 - I/O8 (Don’t Care); I/O7 - I/O0 (Hex). The ADDRESS FORMAT in
each bus cycle is as follows: A11 - A0 (Hex), A11 - A21 (Don’t Care).
2. Since A11 is a Don’t Care, AAA can be replaced with 2AA.
3. SA = sector address. Any word address within a sector can be used to designate the sector address (see pages 13 - 16
for details).
4. The fast programming option enables the user to program two words in parallel only when V
PP
= 10V. The addresses, Addr0
and Addr1, of the two words, D
IN0
and D
IN1
, must only differ in address A0. This command should be used for manufacturing
purpose only.
5. Once a sector is in the lockdown mode, the data in the protected sector cannot be changed, unless the chip is reset or power
cycled.
6. During the fourth bus cycle, the manufacturer code is read from address 00000H, the device code is read from address
00001H, and the data in the protection register is read from addresses 000081H - 000088H.
7. Either one of the Product ID Exit commands can be used.
8. Bytes of data other than F0 may be used to exit the product ID mode. However, it is recommended that F0 be used.
9. Any address within the user programmable register region. Please see “Protection Register Addressing Table” on page 12.
10. If data bit D1 is “0”, block B is locked. If data bit D1 is “1”, block B can be reprogrammed.
11. The default state (after power-up) of the configuration register is “00”.
5. Command Definition Table
Command Sequence
Bus
Cycles
1st Bus
Cycle
2nd Bus
Cycle
3rd Bus
Cycle
4th Bus
Cycle
5th Bus
Cycle
6th Bus
Cycle
Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data
Read 1 Addr D
OUT
Chip Erase 6 555 AA AAA
(2)
55 555 80 555 AA AAA 55 555 10
Sector Erase 6 555 AA AAA 55 555 80 555 AA AAA 55 SA
(3)
30
Word Program 4 555 AA AAA 55 555 A0 Addr D
IN
Dual-Word Program
(4)
5 555 AA AAA 55 555 E0 Addr0 D
IN0
Addr1 D
IN1
Enter Single-pulse Program
Mode
6 555 AA AAA 55 555 80 555 AA AAA 55 555 A0
Single-pulse Word Program
Mode
1 Addr D
IN
Sector Lockdown
(5)
6 555 AA AAA 55 555 80 555 AA AAA 55 SA
(3)(5)
60
Erase/Program Suspend 1 xxx B0
Erase/Program Resume 1 xxx 30
Product ID Entry
(6)
3 555 AA AAA 55 555 90
Product ID Exit
(7)
3 555 AA AAA 55 555 F0
(8)
Product ID Exit
(7)
1 xxx F0
(8)
Program Protection
Register Block B
4 555 AA AAA 55 555 C0 Addr
(9)
D
IN
Lock Protection
Register Block B
4 555 AA AAA 55 555 C0 80 X0
Status of Block B
Protection
4 555 AA AAA 55 555 90 80 D
OUT
(10)
Set Configuration Register 4 555 AA AAA 55 555 D0 xxx 00/01
(11)
CFI Query 1 X55 98
12
3631A–FLASH–04/06
AT49BV642D(T)
Note: All address lines not specified in the above table must be “0” when accessing the protection register, i.e. A21 -A8 = 0.
6. Absolute Maximum Ratings*
Temperature under Bias ................................ -55°C to +125°C
*NOTICE: Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent dam-
age to the device. This is a stress rating only and
functional operation of the device at these or any
other conditions beyond those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Storage Temperature..................................... -65°C to +150°C
All Input Voltages Except V
PP
(including NC Pins)
with Respect to Ground ...................................-0.6V to +6.25V
V
PP
Input Voltage
with Respect to Ground .........................................0V to 10.0V
All Output Voltages
with Respect to Ground ...........................-0.6V to V
CCQ
+ 0.6V
7. Protection Register Addressing Table
Word Use Block A7 A6 A5 A4 A3 A2 A1 A0
0 Factory A 1 0 000001
1 Factory A 1 0 000010
2 Factory A 1 0 000011
3 Factory A 1 0 000100
4 User B 1 0 000101
5 User B 1 0 000110
6 User B 1 0 000111
7 User B 1 0 001000