KMA215 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2014. All rights reserved.
Product data sheet Rev. 1 — 24 February 2014 22 of 50
NXP Semiconductors
KMA215
Programmable angle sensor with SAE J2716 SENT
(1) 40 C to +160 C
(2) 40 C to +140 C
Fig 8. Envelope curve for the magnitude of angular error
DDD


DQJ
_
GHJ




  
Į
Į

GHJ





Table 27. Dynamics
Characteristics are valid for the operating conditions, as specified in Section 9.
Symbol Parameter Conditions Min Typ Max Unit
t
on
turn-on time until first falling edge of SENT
frame
--5ms
f
upd
update frequency
[1]
1.2 - 2.2 kHz
t
s
settling time after an ideal mechanical
angle step of 45, until first
falling edge of start of the
SENT frame where 90 % of
the final value is reached
[2]
--1.8ms
T
clk
clock period SENT clock tick time 3.0 s
[3]
2.7 3.0 3.3 s
SENT clock tick time 4.5 s 3.6 4.5 5.4 s
SENT clock tick time 6.0 s 4.8 6.0 7.2 s
SENT clock tick time 12.0 s 9.6 12.0 14.4 s
SENT clock tick time 24.0 s 19.2 24.0 28.8 s
KMA215 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2014. All rights reserved.
Product data sheet Rev. 1 — 24 February 2014 23 of 50
NXP Semiconductors
KMA215
Programmable angle sensor with SAE J2716 SENT
[1] SENT update rate at T
clk
=3.0s, 6 DATA nibbles and no PAUSE pulse.
[2] The mechanical angle step is not synchronized with the SENT frame. Thus the worst case settling time is extended with the length of a
complete SENT frame.
[3] 12-bit fast mode; T
clk
=2.40s (minimum), 2.67 s (typical), 3.0 s (maximum).
t
jit
jitter time variation of maximum nibble
time (6) compared to the
expected time derived from
the calibration pulse
T
clk
=3.0s--0.1s
T
clk
=4.5s--0.15s
T
clk
=6.0s--0.2s
T
clk
= 12.0 s--0.4s
T
clk
= 24.0 s--0.8s
t
f
fall time from 3.8 V to 1.1 V output
level
SLOPE_TIME setting
6.5 s
4.5 5.5 6.5 s
SLOPE_TIME setting
9.75 s
6.75 8.25 9.75 s
SLOPE_TIME setting
13.0 s
91113s
t
r
rise time from 1.1 V to 3.8 V output
level
SLOPE_TIME setting
6.5 s
--18s
SLOPE_TIME setting
9.75 s
--27s
SLOPE_TIME setting
13.0 s
--36s
t
stab
stabilization time output level below 1.39 V
(LOW) or above 3.8 V (HIGH)
T
clk
=3.0s6--s
T
clk
=4.5s9--s
T
clk
=6.0s12--s
T
clk
= 12.0 s24--s
T
clk
= 24.0 s48--s
t
cmd(ent)
enter command mode time after power-on 20 - 30 ms
t
rec(ov)
overvoltage recovery time after overvoltage - - 4 ms
Table 27. Dynamics
…continued
Characteristics are valid for the operating conditions, as specified in Section 9.
Symbol Parameter Conditions Min Typ Max Unit
KMA215 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2014. All rights reserved.
Product data sheet Rev. 1 — 24 February 2014 24 of 50
NXP Semiconductors
KMA215
Programmable angle sensor with SAE J2716 SENT
[1] To enter the command mode, the OUT/DATA pin must be kept HIGH for at least t
to
before sending the initial command sequence.
[1] Measured at 1 MHz.
Table 28. Programming interface (OWI)
Characteristics are valid for the operating conditions, as specified in Section 9.
Symbol Parameter Conditions Min Typ Max Unit
V
IH
HIGH-level input voltage 80 - - %V
DD
V
IL
LOW-level input voltage - - 20 %V
DD
V
OH
HIGH-level output voltage I
O
=2mA 80 - - %V
DD
V
OL
LOW-level output voltage I
O
=2mA - - 20 %V
DD
I
od
overdrive current absolute value for overdriving
the output buffer
--25mA
t
start
start time LOW level before rising edge
[1]
5-- s
t
stop
stop time HIGH level before falling edge 5 - - s
T
bit
bit period the load capacitance limits the
minimum period
10 - 100 s
T
bit
bit period deviation deviation between received
clock and sent clock
0.8T
bit
1T
bit
1.2T
bit
s
t
w0
pulse width 0 0.175T
bit
0.25T
bit
0.375T
bit
s
t
w1
pulse width 1 0.625T
bit
0.75T
bit
0.825T
bit
s
t
to
time-out time communication reset
guaranteed after minimum t
to
250 - - s
t
tko(slv)
slave takeover time duration of LOW level for
slave takeover
1-5s
t
tko(mas)
master takeover time duration of LOW level for
master takeover
0T
bit
-0.5T
bit
s
t
prog
programming time for a single memory address 20 - - ms
Table 29. Internal capacitances
Characteristics are valid for the operating conditions, as specified in Section 9.
Symbol Parameter Conditions Min Typ Max Unit
C
block
blocking capacitance
[1]
50 100 150 nF
C
L
load capacitance
[1]
1.1 2.2 3.3 nF

KMA215,118

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
SENSOR ANGLE 180 DEG PC PIN
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet