21
FN8111.0
March 28, 2005
V
TRIP1
, V
TRIP2
, Programming Specifications: V
CC
= 2.0-5.5V; Temperature = 25°C
Parameter Description Min. Max. Unit
t
VPS
WDO Program Voltage Setup time 10 µs
t
VPH
WDO Program Voltage Hold time 10 µs
t
TSU
V
TRIPX
Level Setup time 10 µs
t
THD
V
TRIPX
Level Hold (stable) time 10 µs
t
WC
V
TRIPX
Program Cycle 10 ms
t
VPO
Program Voltage Off time before next cycle 1 ms
V
P
Programming Voltage 15 18 V
V
TRAN1
V
TRIP1
Set Voltage Range 2.0 4.75 V
V
TRAN2
V
TRIP2
Set Voltage Range – X40010/11 1.7 4.75 V
V
TRAN2A
V
TRIP2
Set to Voltage Range – X40014/15 0.9 3.5 V
V
tv
V
TRIPX
Set Voltage variation after programming (-40 to +85°C). -25 +25 mV
t
VPS
WDO Program Voltage Setup time 10 µs
X40010, X40011, X40014, X40015