[AK8817VQ]
MS1113-E-00 2009/08
-31-
SYNC Signal waveform, Burst Waveform generator
(1) NTSC-J
90%
50%
10%
50%
Sync rise time
Sync
Horizontal
reference point
50%
Sync Level
50%
H . ref. to B urst Start
Burst Height
Burst
measurement
point
value
Consumer Quality
tolerance
units
Total line period(derived) 63.556 usec
Sync Level 40 +/- 3 IRE
Sync rise time 10% - 90% 140 Max 250 nsec
Horizontal Sync width 50% 4.7 +/- 0.1 usec
Horizontal reference point to
burst start
50% 19 defined by SC/H cycles
Burst * 50% 9 +/- 1 cycles
Burst Height ** 40 +/- 3 IRE
* there is a case where tolerance of Sync rise time is added to Sync width tolerance.
* Measurement of Burst time length is made between
the Burst start point which is defined as the zero-cross point,
preceding the first half-cycle of the sub-carrier where Burst amplitude becomes higher than 50 % level and
the Burst end
point
, defined in the same manner.
9 cycles +/- 1cycle
19 cycles +/-10°
50%
NTSC Signal