SC16C852SV_1 © NXP B.V. 2008. All rights reserved.
Product data sheet Rev. 01 — 23 September 2008 22 of 48
NXP Semiconductors
SC16C852SV
Dual UART with 128-byte FIFOs, IrDA, and XScale VLIO bus interface
7.2.1 IER versus Transmit/Receive FIFO interrupt mode operation
When the receive FIFO is enabled (FCR[0] = logic 1), and receive interrupts
(IER[0] = logic 1) are enabled, the receive interrupts and register status will reflect the
following:
The receive RXRDY interrupt (Level 2 ISR interrupt) is issued to the external CPU
when the receive FIFO has reached the programmed trigger level. It will be cleared
when the receive FIFO drops below the programmed trigger level.
Receive FIFO status will also be reflected in the user accessible ISR register when
the receive FIFO trigger level is reached. Both the ISR register receive status bit and
the interrupt will be cleared when the FIFO drops below the trigger level.
The receive data ready bit (LSR[0]) is set as soon as a character is transferred from
the shift register (RSR) to the receive FIFO. It is reset when the FIFO is empty.
When the Transmit FIFO and interrupts are enabled, an interrupt is generated when
the transmit FIFO is empty due to the unloading of the data by the TSR and UART for
transmission via the transmission media. The interrupt is cleared either by reading the
ISR, or by loading the THR with new data characters.
7.2.2 IER versus Receive/Transmit FIFO polled mode operation
When FCR[0] = logic 1, setting IER[3:0] = zeroes puts the SC16C852SV in the FIFO
polled mode of operation. In this mode, interrupts are not generated and the user must
poll the LSR register for TX and/or RX data status. Since the receiver and transmitter have
separate bits in the LSR either or both can be used in the polled mode by selecting
respective transmit or receive control bit(s).
LSR[0] will be a logic 1 as long as there is one byte in the receive FIFO.
LSR[4:1] will provide the type of receive errors, or a receive break, if encountered.
LSR[5] will indicate when the transmit FIFO is empty.
LSR[6] will indicate when both the transmit FIFO and transmit shift register are empty.
LSR[7] will show if any FIFO data errors occurred.
1 IER[1] Transmit Holding Register interrupt. In the non-FIFO mode, this interrupt will be
issued whenever the THR is empty, and is associated with LSR[5]. In the FIFO
modes, this interrupt will be issued whenever the FIFO is empty.
logic 0 = disable the Transmit Holding Register Empty (TXRDY) interrupt
(normal default condition)
logic 1 = enable the TXRDY (ISR level 3) interrupt
0 IER[0] Receive Holding Register. In the non-FIFO mode, this interrupt will be issued
when the RHR has data, or is cleared when the RHR is empty. In the FIFO mode,
this interrupt will be issued when the FIFO has reached the programmed trigger
level or is cleared when the FIFO drops below the trigger level.
logic 0 = disable the receiver ready (ISR level 2, RXRDY) interrupt (normal
default condition)
logic 1 = enable the RXRDY (ISR level 2) interrupt
Table 8. Interrupt Enable Register bits description
…continued
Bit Symbol Description
SC16C852SV_1 © NXP B.V. 2008. All rights reserved.
Product data sheet Rev. 01 — 23 September 2008 23 of 48
NXP Semiconductors
SC16C852SV
Dual UART with 128-byte FIFOs, IrDA, and XScale VLIO bus interface
7.3 FIFO Control Register (FCR)
This register is used to enable the FIFOs, clear the FIFOs and set the receive FIFO trigger
levels.
7.3.1 FIFO mode
[1] For 128-byte FIFO mode, refer to Section 7.16, Section 7.17, Section 7.18.
[2] For 128-byte FIFO mode, refer to Section 7.15, Section 7.17, Section 7.18.
Table 9. FIFO Control Register bits description
Bit Symbol Description
7:6 FCR[7:6] Receive trigger level in 32-byte FIFO mode.
[1]
These bits are used to set the trigger level for receive FIFO interrupt and flow
control. The SC16C852SV will issue a receive ready interrupt when the
number of characters in the receive FIFO reaches the selected trigger level.
Refer to
Table 10.
5:4 FCR[5:4] Transmit trigger level in 32-byte FIFO mode.
[2]
These bits are used to set the trigger level for the transmit FIFO interrupt and
flow control. The SC16C852SV will issue a transmit empty interrupt when the
number of characters in FIFO drops below the selected trigger level. Refer to
Table 11.
3 FCR[3] reserved
2 FCR[2] XMIT FIFO reset.
logic 0 = no FIFO transmit reset (normal default condition)
logic 1 = clears the contents of the transmit FIFO and resets the FIFO
counter logic. This bit will return to a logic 0 after clearing the FIFO.
1 FCR[1] RCVR FIFO reset.
logic 0 = no FIFO receive reset (normal default condition)
logic 1 = clears the contents of the receive FIFO and resets the FIFO
counter logic. This bit will return to a logic 0 after clearing the FIFO.
0 FCR[0] FIFO enable.
logic 0 = disable the transmit and receive FIFO (normal default condition)
logic 1 = enable the transmit and receive FIFO
SC16C852SV_1 © NXP B.V. 2008. All rights reserved.
Product data sheet Rev. 01 — 23 September 2008 24 of 48
NXP Semiconductors
SC16C852SV
Dual UART with 128-byte FIFOs, IrDA, and XScale VLIO bus interface
[1] When RXINTLVL or TXINTLVL or FLWCNTH or FLWCNTL contains any value other than 0x00, receive and
transmit trigger levels are set by RXINTLVL, TXINTLVL; see Section 6.4 “FIFO operation”.
[1] When RXINTLVL or TXINTLVL or FLWCNTH or FLWCNTL contains any value other than 0x00, receive and
transmit trigger levels are set by RXINTLVL, TXINTLVL; see Section 6.4 “FIFO operation”.
Table 10. RCVR trigger levels
FCR[7] FCR[6] RX FIFO trigger level in 32-byte FIFO mode
[1]
0 0 8 bytes
0 1 16 bytes
1 0 24 bytes
1 1 28 bytes
Table 11. TX FIFO trigger levels
FCR[5] FCR[4] TX FIFO trigger level in 32-byte FIFO mode
[1]
0 0 16 bytes
0 1 8 bytes
1 0 24 bytes
1 1 30 bytes