SL2S2602 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 4.1 — 25 July 2017
COMPANY PUBLIC 276341 16 / 55
Option 1 (Option flag set) is supported.
If the addressed block is part of a write protected page or only protected with the read
password (see Section 9.5.3.6 "PROTECT PAGE") and the password has not been
transmitted first with the SET PASSWORD command, the label will respond according to
the error handling (see Section 9.6 "Error handling").
Remark: Block 79 of the user memory contains the 16 bit counter feature and can not be
locked (refer to section "16 bit counter feature").
9.5.2.4 READ MULTIPLE BLOCKS
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
If one of the addressed blocks is part of a page protected with the Read-Password and
the password has not been transmitted first with the SET PASSWORD command the
label will respond according to the error handling (see Section 9.6 "Error handling").
Remark: Block 79 of the user memory contains the 16 bit counter feature and needs to
be treated differently (refer to section "16 bit counter feature").
9.5.2.5 SELECT
As defined in ISO/IEC 15693-3.
9.5.2.6 RESET TO READY
As defined in ISO/IEC 15693-3.
Remark: RESET TO READY also resets the label IC from the persistent quiet state
(refer to Section 9.5.3.10 "INVENTORY READ" and Section 9.5.3.19 "STAY QUIET
PERSISTENT")into the READY state.
9.5.2.7 WRITE AFI
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Remark: This command maybe password protected, refer to Section 9.5.3.16
"PASSWORD PROTECT EAS/AFI".
9.5.2.8 LOCK AFI
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Remark: This command maybe password protected, refer to Section 9.5.3.16
"PASSWORD PROTECT EAS/AFI".
NXP Semiconductors
SL2S2602
ICODE SLIX2
SL2S2602 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 4.1 — 25 July 2017
COMPANY PUBLIC 276341 17 / 55
9.5.2.9 WRITE DSFID
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.5.2.10 LOCK DSFID
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.5.2.11 GET SYSTEM INFORMATION
As defined in ISO/IEC 15693-3.
The TAG type of the ICODE SLIX2 IC is "01h".
9.5.2.12 GET MULTIPLE BLOCK SECURITY STATUS
As defined in ISO/IEC 15693-3.
9.5.3 Custom commands
The manufacturer code of NXP Semiconductors is defined in ISO/IEC 7816-6A1 (Ref. 5).
It has the value "04h".
For the structure of custom commands please refer to ISO/IEC 15693-3.
If not explicitly specified differently all address modes are supported.
9.5.3.1 GET RANDOM NUMBER
Command code = B2h
The GET RANDOM NUMBER command is required to receive a random number from
the label IC. The passwords that will be transmitted with the SET PASSWORD,ENABLE
PRIVACY and DESTROY commands have to be calculated with the password and the
random number (see Section 9.5.3.2 "SET PASSWORD").
The different passwords are addressed with the password identifier.
Table 9. GET RANDOM NUMBER request format
SOF Flags GET
RANDOM
NUMBER
IC Mfg
code
UID CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
16 bits -
NXP Semiconductors
SL2S2602
ICODE SLIX2
SL2S2602 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 4.1 — 25 July 2017
COMPANY PUBLIC 276341 18 / 55
Table 10. GET RANDOM NUMBER response when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 11. GET RANDOM NUMBER response format when Error_flag NOT set
SOF Flags Random
number
CRC16 EOF
- 8 bits 16 bits 16 bits -
9.5.3.2 SET PASSWORD
Command code = B3h
The SET PASSWORD command enables the different passwords to be transmitted to
the label to access the different protected functionalities of the following commands. The
SET PASSWORD command has to be executed just once for the related passwords if
the label is powered.
Remark: The SET PASSWORD command can only be executed in Addressed or
Selected mode except for the Privacy password. If the Privacy password is transmitted
(see Section 9.5.3.9 "ENABLE PRIVACY"), the timing of the SET PASSWORD command
is write alike.
The XOR password has to be calculated with the password and two times the received
random number from the last GET RANDOM NUMBER command:
XOR_Password[31:0] = Password[31:0] XOR {Random_Number[15:0],
Random_Number[15:0]}.
The different passwords are addressed with the password identifier.
Table 12. SET PASSWORD request format
SOF Flags SET
PASSWORD
IC Mfg
code
UID Password
identifier
XOR
password
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 32 bits 16 bits -
Table 13. Password Identifier
Password identifier Password
01h Read
02h Write
04h Privacy
08h Destroy
10h EAS/AFI