M41T00S DC and AC parameters
Doc ID 10772 Rev 5 19/28
Table 7. DC characteristics
Table 8. Crystal electrical characteristics
Figure 13. Power down/up mode AC waveforms
Sym Parameter Test condition
(1)
1. Valid for ambient operating temperature: T
A
= –40 to 85 °C; V
CC
= 2.7 to 5.5 V (except where noted).
Min Typ Max Unit
I
LI
Input leakage current 0 V V
IN
V
CC
±1 μA
I
LO
Output leakage current 0 V V
OUT
V
CC
±1 μA
I
CC1
Supply current Switch freq = 400 kHz 300 μA
I
CC2
Supply current (standby)
SCL = 0 Hz
All Inputs
V
CC
– 0.2 V
V
SS
+ 0.2 V
70 μA
V
IL
Input low voltage –0.3 0.3V
CC
V
V
IH
Input high voltage 0.7V
CC
V
CC
+ 0.3 V
V
OL
Output low voltage I
OL
= 3.0 mA 0.4 V
Output low voltage (open drain)
(2)
2. For FT/OUT pin (open drain).
I
OL
= 10 mA 0.4 V
Pull-up supply voltage (open drain) FT/OUT 5.5 V
V
BAT
(3)
3. STMicroelectronics recommends the RAYOVAC BR1225 or BR1632 (or equivalent) as the battery supply.
Backup supply voltage 2.0 3.5
(4)
4. For rechargeable backup, V
BAT
(max) may be considered to be V
CC
.
V
I
BAT
Battery supply current
T
A
= 25 °C, V
CC
= 0 V
Oscillator ON, V
BAT
= 3 V
0.6 1 µA
Sym Parameter
(1)(2)
1. Externally supplied if using the SO8 package. STMicroelectronics recommends the KDS DT-38: 1TA/1TC252E127, Tuning
Fork Type (thru-hole) or the DMX-26S: 1TJS125FH2A212, (SMD) quartz crystal for industrial temperature operations. KDS
can be contacted at kouhou@kdsj.co.jp or http://www.kdsj.co.jp for further information on this crystal type.
2. Load capacitors are integrated within the M41T00S. Circuit board layout considerations for the 32.768 kHz crystal of
minimum trace lengths and isolation from RF generating signals should be taken into account.
Min Typ Max Units
f
O
Resonant frequency 32.768 kHz
R
S
Series resistance 60
(3)
3. For applications requiring backup supply operation below 2.5 V, R
S
(max) should be considered 40 kΩ.
kΩ
C
L
Load capacitance 12.5 pF
AI00596
V
CC
trec
tPD
V
SO
SDA
SCL
DON'T CARE
DC and AC parameters M41T00S
20/28 Doc ID 10772 Rev 5
Table 9. Power down/up AC characteristics
Table 10. Power down/up trip points DC characteristics
Figure 14. Bus timing requirements sequence
Symbol Parameter
(1)(2)
1. V
CC
fall time should not exceed 5 mV/µs.
2. Valid for ambient operating temperature: T
A
= –40 to 85 °C; V
CC
= 2.7 to 5.5 V (except where noted).
Min Typ Max Unit
t
PD
SCL and SDA at V
IH
before power-down 0 nS
t
rec
SCL and SDA at V
IH
after power-up 10 µS
Sym Parameter
(1)(2)
1. All voltages referenced to V
SS
.
2. Valid for ambient operating temperature: T
A
= –40 to 85 °C; V
CC
= 2.7 to 5.5 V (except where noted).
Min Typ Max Unit
V
PFD
Power-fail deselect 2.5 2.6 2.7 V
Hysteresis 25 mV
V
SO
Battery backup switchover voltage
(V
CC
< V
BAT
; V
CC
< V
PFD
)
V
BAT
< V
PFD
V
BAT
V
V
BAT
> V
PFD
V
PFD
V
Hysteresis 40 mV
AI00589
SDA
P
tSU:STOtSU:STA
tHD:STA
SR
SCL
tSU:DAT
tF
tHD:DAT
tR
tHIGH
tLOW
tHD:STAtBUF
SP
M41T00S DC and AC parameters
Doc ID 10772 Rev 5 21/28
Table 11. AC characteristics
Sym Parameter
(1)
1. Valid for ambient operating temperature: T
A
= –40 to 85 °C; V
CC
= 2.7 to 5.5 V (except where noted).
Min Typ Max Units
f
SCL
SCL clock frequency 0 400 kHz
t
LOW
Clock low period 1.3 µs
t
HIGH
Clock high period 600 ns
t
R
SDA and SCL rise time 300 ns
t
F
SDA and SCL fall time 300 ns
t
HD:STA
START condition hold time
(after this period the first clock pulse is generated)
600 ns
t
SU:STA
START condition setup time
(only relevant for a repeated start condition)
600 ns
t
SU:DAT
(2)
2. Transmitter must internally provide a hold time to bridge the undefined region (300 ns max) of the falling
edge of SCL.
Data setup time 100 ns
t
HD:DAT
Data hold time 0 µs
t
SU:STO
STOP condition setup time 600 ns
t
BUF
Time the bus must be free before a new
transmission can start
1.3 µs