Spec.No. JENF243H-9101A-01 P 9/ 13
MURATA MFG.CO.,LTD.
Reference Only
11.2.Direction of mounting
Please make sure of the direction of mounting and connect to the circuit properly.
As shown in the equivalent circuit shown in item 5, this product has a directionality.
Wrong connection to the circuit may cause open/short circuit of the part, burnout and serious accidents.
11.3.Caution (Rating)
< Self-heating >
Though this product has a large rated current,following attention should be paid.
(1) Do not use this product beyond the ratings such as rated voltage and rated current/derating condition.
Then burnout may occurred by self-heating.
(2)After installing this product in your product, please make sure of the self-heating with the rated current.
11.4. Attention regarding product's lay out
< Attention regarding the heat generated by other products >
Please provide special attention when mounting products in close proximity to other products that radiate heat.
Failure to follow the above cautions may result, worst case, in a short circuit and cause fuming or firing when the
product is used.
11.5.
Fail-safe
Be sure to provide an appropriate fail-safe function on your product to prevent a second damage that may be caused
by the abnormal function or the failure of our product.
11.6.ESD
ESD to this product, exceeding condition of IEC61000-4-2 with 30kV, may cause short circuit and fuming or firing.
11.7.Limitation of Applications
Please contact us before using our products for the applications listed below which require especially high
reliability for the prevention of defects which might directly cause damage to the third party’s life,body or property.
(1)Aircraft equipment (2)Aerospace equipment (3)Undersea equipment (4)Power plant control equipment
(5)Medical equipment (6)Transportation equipment(trains,ships,etc.) (7)Traffic signal equipment
(8)Disaster prevention / crime prevention equipment (9)Data-processing equipment
(10)Applications of similar complexity or with reliability requirements comparable to the applications listed in the above
12.Notice
Products can only be soldered with reflow.
This product is designed for solder mounting.
Please consult us in advance for applying other mounting method such as conductive adhesive.
12.1. Flux and Solder
Flux
Use rosin-based flux, Do not use highly acidic flux (with chlorine content
exceeding 0.2(wt)%).
Do not use water soluble flux.
Solder Use Sn-3.0Ag-0.5Cu solder
Other flux (except above) Please contact us for details, then use.