Figure 17. Optoisolating the I
2
C Bus
APPLICATIO S I FOR ATIO
WUUU
4258 F15
V
DD
INT
SCL
SDAIN
SDAOUT
AD0
AD1
AD2
AD3
DGND
AGND
LTC4258
BYP
V
DD
INT
SCL
SDAIN
SDAOUT
AD0
AD1
AD2
AD3
DGND
AGND
LTC4258
V
DD
INT
SCL
SDAIN
SDAOUT
AD0
AD1
AD2
AD3
DGND
AGND
LTC4258
V
DD
INT
SCL
SDAIN
SDAOUT
AD0
AD1
AD2
AD3
DGND
AGND
LTC4258
V
DD
INT
SCL
SDAIN
SDAOUT
AD0
AD1
AD2
AD3
DGND
AGND
LTC4258
0.1µF
0.1µF
0.1µF
0.1µF
0.1µF
+
10µF
2k
2k
0.1µF
0.1µF
0.1µF
BYP
0.1µF
BYP
0.1µF
BYP
0.1µF
BYP
0.1µF
200
200
200
200
U2
U3
U1
HCPL-063L
HCPL-063L
V
DD
CPU
SCL
SDA
SMBALERT
GND CPU
U1: FAIRCHILD NC7WZ17
U2, U3: AGILENT HCPL-063L
TO
CONTROLLER
ISOLATED
3.3V
ISOLATED
GND
0100000
0100001
0100010
0101110
0101111
I
2
C ADDRESS
LTC4258
23
4258fb
Acknowledge
The Acknowledge signal is used for handshaking between
the master and the slave. An Acknowledge (active LOW)
generated by the slave lets the master know that the latest
byte of information was received. The corresponding SCL
clock pulse is always generated by the master. The master
releases the SDA line (HIGH) during the Acknowledge
clock pulse. The slave must pull down the SDA line during
the Acknowledge clock pulse so that it remains a stable
LOW during the HIGH period of this clock pulse. When the
master is reading from a slave device, it is the master’s
responsibility to acknowledge receipt of the data byte in
the bit that follows unless the transaction is complete. In
that case the master will decline to acknowledge and issue
the STOP condition to terminate the communication.
Write Byte Protocol
The master initiates communication to the LTC4258 with
a START condition and a 7-bit bus address followed by the
Write Bit (Wr) = 0. If the LTC4258 recognizes its own
address, it acknowledges and the master delivers the com-
mand byte, signifying to which internal LTC4258 register
the master wishes to write. The LTC4258 acknowl
edges
and latches the lower five bits of the command byte into its
Register Address register. Only the lower five bits of the
command byte are checked by the LTC4258; the upper
three bits are ignored. The master then delivers the data
byte. The LTC4258 acknowledges once more and latches
the data into the appropriate control register. Finally, the
master terminates the communication with a STOP condi-
tion. Upon reception of the STOP condition, the Register
Address register is cleared (see Figure 6).
Read Byte Protocol
The master initiates communication from the LTC4258
with a START condition and the same 7-bit bus address
followed by the Write Bit (Wr) = 0. If the LTC4258
recognizes its own address, it acknowledges and the
master delivers the command byte, signifying which
internal LTC4258 register it wishes to read from. The
LTC4258 acknowledges and latches the lower five bits of
the command byte into its Register Address register. At
this time the master sends a REPEATED START condition
and the same 7-bit bus address followed by the Read Bit
(Rd) = 1. The LTC4258 acknowledges and sends the
contents of the requested register. Finally, the master
declines to acknowledge and terminates communication
with a STOP condition. Upon reception of the STOP
condition, the Register Address register is cleared (see
Figure 7).
Receive Byte Protocol
Since the LTC4258 clears the Register Address register on
each STOP condition, the interrupt register (register 0)
may be read with the Receive Byte Protocol as well as with
the Read Byte Protocol. In this protocol, the master
initiates communication with the LTC4258 with a START
condition and a 7-bit bus address followed by the Read Bit
(Rd) = 1. The LTC4258 acknowledges and sends the
contents of the interrupt register. The master then de-
clines to acknowledge and terminates communication
with a STOP condition (see Figure 8).
Alert Response Address and the INT Pin
In a system where several LTC4258s share a common INT
line, the master can use the Alert Response Address (ARA)
to determine which LTC4258 initiated the interrupt.
The master initiates the ARA procedure with a START
condition and the 7-bit ARA bus address (0001100)b
followed by the Read Bit (Rd) = 1. If an LTC4258 is
asserting the INT pin, it acknowledges and sends its 7-bit
bus address (010A
3
A
2
A
1
A
0
)b and a 1 (see Figure 9). While
it is sending its address, it monitors the SDAIN pin to see
if another device is sending an address at the same time
using standard I
2
C bus arbitration. If the LTC4258 is
sending a 1 and reads a 0 on the SDAIN pin on the rising
edge of SCL, it assumes another device with a lower
address is sending and the LTC4258 immediately aborts
its transfer and waits for the next ARA cycle to try again.
If transfer is successfully completed, the LTC4258 will
stop pulling down the INT pin. When the INT pin is released
in this way or if a 1 is written into the Clear Interrupt pin bit
(bit 6 of register 1Ah), the condition causing the LTC4258
to pull the INT pin down must be removed before the
LTC4258 will be able to pull INT down again. This can be
done by reading and clearing the event registers or by
writing a 1 into the Clear All Interrupts bit (bit 7 of register
APPLICATIO S I FOR ATIO
WUUU
LTC4258
24
4258fb
1Ah). The state of the INT pin can only change between I
2
C
transactions, so an interrupt is cleared or new interrupts
are generated after a transaction completes and before
new I
2
C bus communication commences. Periodic polling
of the alert response address can be used instead of the
INT pin if desired. If any device acknowledges the alert
response address, then the INT line, if connected, would
have been low.
System Software Strategy
Control of the LTC4258 hinges on one decision, the
LTC4258’s operating mode. The three choices are de-
scribed under Operating Modes. In Auto mode the LTC4258
can operate autonomously without direction from a host
controller. Because LTC4258s running in Auto mode will
power every valid PD connected to them, the PSE must
have 15.4W/port available. To reduce the power require-
ments of the –48V supply, PSE systems can track power
usage, only turning on ports when sufficient power is
available. The IEEE describes this as a power allocation
algorithm and places two limitations: the PSE shall not
power a PD unless it can supply the guaranteed power for
that PD’s class (see Table 2) and power allocation may not
be based solely on a history of each PD’s power consump-
tion. In order for a PSE to implement power allocation, the
PSE’s processor/controller must control whether ports
are powered—the LTC4258 cannot be allowed to operate
in Auto mode. Semiauto mode fits the bill as the LTC4258
automatically detects and classifies PDs, then makes this
information available to the host controller, which de-
cides to apply power or not. Operating the LTC4258 in
Manual mode also lets the controller decide whether to
power the ports but the controller must also control
detection and classification. If the host controller oper-
ates near the limit of its computing resources, it may not
be able to guide a Manual mode LTC4258 through detect,
classification and port turn-on in less than the IEEE
mandated maximum of 950ms.
In a typical PSE, the LTC4258s will operate in Semiauto
mode as this allows the controller to decide to power a
port without unduly burdening the controller. With an
interrupt mask of F4h, the LTC4258 will signal to the host
after it has successfully detected and classified a PD, at
APPLICATIO S I FOR ATIO
WUUU
which point the host can decide whether enough power is
available and command the LTC4258 to turn that port on.
Similarly, the LTC4258 will generate interrupts when a
port’s power is turned off. By reading the LTC4258’s
interrupt register, the host can determine if a port was
turned off due to overcurrent (t
START
or t
ICUT
faults) or
because the PD was removed (Disconnect event). The
host then updates the amount of available power to reflect
the power no longer consumed by the disconnected PD.
Setting the MSB of the interrupt mask causes the LTC4258
to communicate fault conditions caused by failures within
the PSE, so the host does not need to poll to check that the
LTC4258s are operating properly. This interrupt driven
system architecture provides the controller with the final
say on powering ports at the same time, minimizing the
controller’s computation requirements because inter-
rupts are only generated when a PD is detected or on a
fault condition.
The LTC4258 can also be used to power older powered
Ethernet devices that are not 802.3af compliant and may
be detected with other methods. Although the LTC4258
does not implement these older detection methods auto-
matically, if software or external circuitry can detect the
noncompliant devices, the host controller may command
the LTC4258 to power the port, bypassing IEEE compliant
detection and classification and sending power to the
noncompliant device.
LOGIC LEVEL SUPPLY
In additon to the 48V used to source power to each port,
a logic level supply is required to power the digital portion
of the LTC4258. To simplify design and meet voltage
isolation requirements, the logic level supply can be
generated from the isolated –48V supply. Figure 18
shows an example method using an LTC3803 to control
a –48V to 3.3V current mode supply. This boost con-
verter topology uses the LTC3803 current mode control-
ler and a current mirror which reflects the 3.3V output
voltage to the –48V rail, improving the regulation toler-
ance over the more traditional large resistor voltage
divider. This approach achieves high accuracy with a
transformerless design.

LTC4258CGW#TRPBF

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Power Switch ICs - POE / LAN 4x IEEE 802.3af Pwr over E Cntr w/ Int D
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet