TCFG series P Case
Tantalum capacitors
Rev.A 4/13
Temperature
Stability
−
Shall be satisfied the voltage on "Standard list"
5µA or 0.1CV whichever is greater
6.3µA or 0.125CV whichever is greater
+125
°C
Apply the specified surge voltage every 5±0.5mi
for 30±5 s. each time in the atmospheric conditio
of 85±2°C.
Repeat this procedure 1,000 times.
Surge
Voltage
There should be no significant abnormality.
Shall be satisfied the voltage on "Standard list"
Within 0/−15%of initial value
−55
°C
+85
°C
Shall be satisfied the voltage on "Standard list"
Within +15/0%of initial value
Within +20/0%of initial value
Within
±
10%of initial value
Shall be satisfied the voltage on "Standard list"
Loading at
High
temperature
There should be no significant abnormality.
After applying the rated voltage for 1000+36/0
without discontinuation via the serial resistanc
of 3Ω or less at a temperature of 85
±
2
°C
, leav
the sample at room temperature/humidity for
1 to 2h and measure the value.
Within
±
10%of initial value
Less than initial limit
Terminal
Strength
The measured value should be stable.
A force is applied to the terminal until it bends
to 1mm and by a prescribed tool maintain the
condition for 5s. (See the figure below.)
Temp.
∆C / C
L.C
Temp.
∆C / C
tanδ
L.C
∆C / C
L.C
Temp.
Appearance
∆C / C
tanδ
L.C
tanδ
tanδ
Appearance
∆C / C
L.C
tanδ
Capacitance
Appearance
There should be no significant abnormality.
1
F (Apply force)
(Unit : mm)
20
50
R230
45 45
Thickness 1.6mm
Adhesiveness The terminal should not come off.
Apply force of 5N in the two directions shown
in the figure below for 10
±
1s after mounting
the terminal on a circuit board.
Apply force
a circuit board
product
C105
YAA
As per 4.29 JIS C 5101-1
As per 4.13 JIS C 5101-3
As per 4.26 JIS C 5101-1
As per 4.14 JIS C 5101-3
As per 4.23 JIS C 5101-1
As per 4.15 JIS C 5101-3
As per 4.35 JIS C 5101-1
As per 4.9 JIS C 5101-3
As per 4.34 JIS C 5101-1
As per 4.8 JIS C 5101-3
Item Performance
Test conditions
(based on JIS C5101-1 and JIS C5101-3)
Less than 150% of initial limit