Page 28 ams Datasheet
Document Feedback [v1-10] 2018-Mar-08
TCS3430 − Tap e & R e e l I n fo r m at i on
Figure 43:
Tape & Reel Information
Note(s):
1. All linear dimensions are in millimeters.
2. For missing tolerances and dimensions, refer to EIA-481.
Tape & Reel Information
ams Datasheet Page 29
[v1-10] 2018-Mar-08 Document Feedback
TCS3430 − Soldering & Storage Information
The module has been tested and has demonstrated an ability
to be reflow soldered to a PCB substrate.
The solder reflow profile describes the expected maximum heat
exposure of components during the solder reflow process of
product on a PCB. Temperature is measured on top of
component. The components should be limited to a maximum
of three passes through this solder reflow profile.
Figure 44:
Solder Reflow Profile
Figure 45:
Solder Reflow Profile Graph
Parameter Reference Device
Average temperature gradient in preheating 2.5°C/s
Soak time t
soak
2 to 3 minutes
Time above 217°C (T
1
)t
1
Max 60s
Time above 230°C (T
2
)t
2
Max 50s
Time above T
peak
– 10 °C (T
3
)t
3
Max 10s
Peak temperature in reflow T
peak
260°C
Temperature gradient in cooling Max −5°C/s
Soldering & Storage
Information
NottoScale
T
peak
Temperaturein°C
Timeinseconds
t
2
T
2
T
3
T
1
t
3
Page 30 ams Datasheet
Document Feedback [v1-10] 2018-Mar-08
TCS3430 − Soldering & Storage Information
Storage Information
Moisture Sensitivity
Optical characteristics of the device can be adversely affected
during the soldering process by the release and vaporization of
moisture that has been previously absorbed into the package.
To ensure the package contains the smallest amount of
absorbed moisture possible, each device is baked prior to being
dry packed for shipping.
Devices are dry packed in a sealed aluminized envelope called
a moisture-barrier bag with silica gel to protect them from
ambient moisture during shipping, handling, and storage
before use.
Shelf Life
The calculated shelf life of the device in an unopened moisture
barrier bag is 12 months from the date code on the bag when
stored under the following conditions:
Shelf Life: 12 months
Ambient Temperature: <40°C
Relative Humidity: <90%
Rebaking of the devices will be required if the devices exceed
the 12 month shelf life or the Humidity Indicator Card shows
that the devices were exposed to conditions beyond the
allowable moisture region.
Floor Life
The module has been assigned a moisture sensitivity level of
MSL 3. As a result, the floor life of devices removed from the
moisture barrier bag is 168 hours from the time the bag was
opened, provided that the devices are stored under the
following conditions:
Floor Life: 168 hours
Ambient Temperature: <30°C
Relative Humidity: <60%
If the floor life or the temperature/humidity conditions have
been exceeded, the devices must be rebaked prior to solder
reflow or dry packing.
Rebaking Instructions
When the shelf life or floor life limits have been exceeded,
rebake at 50°C for 12 hours.

TCS34303

Mfr. #:
Manufacturer:
ams
Description:
Ambient Light Sensors TCS34303 OLGA8 LF T&RDP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union