Data Sheet ADuM1240/ADuM1241/ADuM1245/ADuM1246
Rev. B | Page 7 of 24
Table 10.
Parameter Symbol
Min
Typ
Max
Unit Test Conditions/Comments
SUPPLY CURRENT 2 Mbps, no load
ADuM1240/ADuM1245 I
DD1
306 500 µA
I
DD2
248 375 µA
ADuM1241/ADuM1246 I
DD1
240 375 µA
I
DD2
306 450 µA
PACKAGE CHARACTERISTICS
Table 11.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
R
I-O
10
13
Capacitance (Input to Output)
1
C
I-O
2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction to Ambient Thermal Resistance θ
JA
85 °C/W Thermocouple located at center of package underside
1
The device is considered a 2-terminal device: Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
See Table 18 and the Absolute Maximum Ratings section for recommended maximum working voltages for specific cross isolation
waveforms and insulation levels.
Table 12.
UL CSA VDE
Recognized under 1577 component
recognition program
1
Approved under CSA Component Acceptance Notice 5A Certified according to DIN V VDE V
0884-10 (VDE V 0884-10): 2006-12
2
Single protection, 8-lead SOIC package,
3000 V rms isolation voltage
8-lead SOIC package, basic insulation per CSA 60950-1-03
and IEC 60950-1, 400 V rms (565 V peak) maximum working
voltage
8-lead SOIC package, reinforced
insulation, 560 V
PEAK
Single protection, 20-lead SSOP package,
3750 V rms isolation voltage
20-lead SSOP package, basic insulation per CSA 60950-1-03
and IEC 60950-1, 530 V rms (700 V peak) maximum working
voltage
20-lead SSOP package, reinforced
insulation, 849 V
PEAK
20-lead SSOP package, reinforced insulation per CSA
60950-1-03 and IEC 60950-1, 265 V rms (374 V peak)
maximum working voltage
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL1577, each ADuM1240/ADuM1241/ADuM1245/ADuM1246 is proof tested by applying an insulation test voltage ≥3000 V rms for 1 second
(current leakage detection limit = 5 µA).
2
In accordance with DIN V VDE V 0884-10, each ADuM1240/ADuM1241/ADuM1245/ADuM1246 is proof tested by applying an insulation test voltage ≥1050 V peak for
1 second (partial discharge detection limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10
approval.
ADuM1240/ADuM1241/ADuM1245/ADuM1246 Data Sheet
Rev. B | Page 8 of 24
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 13.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage
(8-Lead SOIC)
3000
V rms
1 minute duration
Rated Dielectric Insulation Voltage
(20-Lead SSOP)
3750 V rms 1 minute duration
Minimum External Tracking and Air Gap,
8-Lead SOIC (Creepage and Clearance)
L(I02) 4 mm min Measured from input terminals to output terminals,
shortest distance path along package body
Minimum Clearance in the Plane of the
Printed Circuit Board, 8-Lead SOIC (PCB
Clearance)
L(I01) 4.5 mm min Measured from input terminals to output terminals, shortest
distance through air, line of sight, in the PCB mounting plane
Minimum Clearance in the Plane of the
Printed Circuit Board, 20-Lead SSOP
(PCB Clearance)
L(I01) 5.1 mm min Measured from input terminals to output terminals,
shortest distance path along package body
Minimum Clearance in the Plane of the
Printed Circuit Board, 20-Lead SSOP
(PCB Clearance)
L(I02) 5.1 mm min Measured from input terminals to output terminals, shortest
distance through air, line of sight, in the PCB mounting plane
Minimum Internal Gap (Internal
Clearance)
0.017 mm min Insulation distance through insulation
Tracking Resistance (Comparative
Tracking Index)
CTI >400 V DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12 INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation within the safety limit data only. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marked on packages denotes DIN V VDE V 0884-10 approval.
Table 14. 8-Lead SOIC (R-8)
Parameter Symbol Test Conditions/Comments Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage 150 V rms I to IV
For Rated Mains Voltage 300 V rms I to III
For Rated Mains Voltage 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage
V
IORM
560
V
PEAK
Input to Output Test Voltage, Method b1 V
pd(m)
V
IORM
× 1.875 = V
pd(m)
, 100% production test,
t
ini
= t
m
= one second, partial discharge < 5 pC
1050 V
PEAK
Input to Output Test Voltage, Method a
After Environmental Tests Subgroup 1 V
pd(m)
V
IORM
× 1.5 = V
pd(m)
, t
ini
= 60 seconds, t
m
= 10 seconds,
partial discharge < 5 pC
840 V
PEAK
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
pd(m)
V
IORM
× 1.2 = V
pd(m)
, t
ini
= 60 seconds, t
m
= 10 seconds,
partial discharge < 5 pC
672
V
PEAK
Highest Allowable Overvoltage V
IOTM
3500 V
PEAK
Surge Isolation Voltage V
IOSM
V
PEAK
= 10 kV, 1.2 µs rise time, 50 µs, 50% fall time 4000 V
PEAK
Safety Limiting Values Maximum value allowed in the event of a failure
(see Figure 4)
Case Temperature T
S
150 °C
Total Power Dissipation at 25°C I
S1
1.64 W
Insulation Resistance at T
S
R
S
V
IO
= 500 V >10
9
Data Sheet ADuM1240/ADuM1241/ADuM1245/ADuM1246
Rev. B | Page 9 of 24
Table 15. 20-Lead SSOP (RS-20)
Parameter Symbol Test Conditions/Comments Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage 150 V rms I to IV
For Rated Mains Voltage 300 V rms I to III
For Rated Mains Voltage 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
849 V
PEAK
Input to Output Test Voltage, Method b1 V
pd(m)
V
IORM
× 1.875 = V
pd(m)
, 100% production test,
t
ini
= t
m
= one second, partial discharge < 5 pC
1592 V
PEAK
Input to Output Test Voltage, Method a
After Environmental Tests Subgroup 1 V
pd(m)
V
IORM
× 1.5 = V
pd(m)
, t
ini
=60 seconds,
t
m
= 10 seconds, partial discharge < 5 pC
1273 V
PEAK
After Input and/or Safety Test Subgroup 2 and
Subgroup 3
V
pd(m)
V
IORM
× 1.2 = V
pd(m)
, t
ini
= 60 seconds,
t
m
= 10 seconds, partial discharge < 5 pC
1018 V
PEAK
Highest Allowable Overvoltage V
IOTM
5335 V
PEAK
Surge Isolation Voltage
V
IOSM
V
PEAK
= 10 kV, 1.2 µs rise time, 50 µs,
50% fall time
6000
V
PEAK
Safety Limiting Values Maximum value allowed in the event of a
failure (see Figure 4)
Case Temperature T
S
150 °C
Side 1 I
DD1
Current
I
S1
2.5
W
Insulation Resistance at T
S
R
S
V
IO
= 500 V >10
9
0
0.5
1.0
1.5
2.0
2.5
3.0
0
50
100 150 200
SAFE LIMITING POWER (W)
AMBIENT TEMPERATURE (°C)
11925-003
Figure 4. Thermal Derating Curve, Dependent on Safety Limiting Values with
Ambient Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 16.
Parameter Symbol Min Max Unit
Operating Temperature T
A
−40 +125 °C
Supply Voltages
1
V
DD1
, V
DD2
2.25 3.6 V
Input Signal Rise and Fall Times 1.0 ms
1
See the DC Correctness and Low Power Operation section for more
information.

ADUM1240ARZ-RL7

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators DUAL-CHANNEL DI GITAL ISOLATORS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union