NB3L202K
www.onsemi.com
10
Figure 10. Typical Termination Configuration for Output Driver and Device Evaluation
A. Connect 475 W resistor R
REF
from I
REF
pin to GND.
B. R
S1
, R
S2
: 33 W for Test and Evaluation. Select to Minimizing Ringing.
C. C
L1
, C
L2
: Receiver Input Simulation (for test only not added to application circuit.
D. R
L1
, R
L2
Termination and Load Resistors Located at Received Inputs.
C
L1
2 pF
C
L2
2 pF
Z
0
= 50 W
Z
0
= 50 W
Receiver
R
S1
R
S2
HCSL
Driver
R
REF
R
L1
50 W
R
L2
50 W
DIF_n#
DIF_n
I
REF
Figure 11. HCSL Simplified Output Structure
I
REF
C1
3.3 V
M
Mir
M
Dum
I
OUT
V
Mirror
2R
R
R
REF
Out_predrv
OUT
OUT
~1.1 V
M
OUTB
M
OUT
M
Iref
NB3L202K
www.onsemi.com
11
Figure 12. HCSL Interface Termination to LVDS
HCSL
Device
LVDS
Device
Qx
Qx
Z
o
= 50 W
Z
o
= 50 W
R
L
= 150 W R
L
= 150 W
100 W 100 W
GND
R
REF
IREF
NB3L202K
MEASUREMENT POINTS FOR DIFFERENTIAL
TRise (Clock)
TFall (Clock#)
Figure 13. Single−Ended Measurement Points for Trise, Tfall
V
OH
= 0.525 V
V
OL
= 0.175 V
V
Cross
Figure 14. Single−Ended Measurement Points for V
ovs
, V
uds
, V
rb
V
ovs
V
high
V
rb
V
rb
V
low
V
uds
NB3L202K
www.onsemi.com
12
TPeriod
High Duty Cycle% Low Duty Cycle%
Skew measurement point
0.000 V
Figure 15. Differential (CLOCK – CLOCK#) Measurement Points (Tperiod, Duty Cycle)
Crossing Point (mV)
V
high
Average (mV)
Equ 1: V
cross(rel)
Max = 0.550 − 0.5(0.7 − V
high avg
)
Equ 2: V
cross(rel)
Min = 0.250 + 0.5(V
high avg
− 0.7)
ForVhigh< 700mV
Use Equ.1
ForVhigh> 700mV
Use Equ.2
Figure 16. V
cross
Range Clarification (Note 40)
40.The picture above illustrates the effect of V
high
above and below 700 mV on the V
cross
range. The purpose of this is to prevent a 250 mV
V
cross
with an 850 mV V
high
. In addition, this prevents the case of a 550 mV V
cross
with a 660 mV V
high
. The actual specification for V
cross
is dependent upon the measured amplitude of V
high
.
V
cross(rel)
Max
V
cross(rel)
Min
550
500
450
400
350
300
250
200
625 650 675 700 725 750 775 800 825 850

NB3L202KMNG

Mfr. #:
Manufacturer:
ON Semiconductor
Description:
Clock Buffer 1:2 HCSL FANOUT BUFFER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet