HMC260ALC3B Data Sheet
Rev. 0 | Page 12 of 16
IF BANDWIDTH—UPCONVERTER
Upper sideband, RF
OUT
= 20 GHz.
0
–20
0.1 8.1
CONVERSION GAIN (dB)
IF
IN
FREQUENCY (GHz)
–15
–10
–5
1.1 2.1 3.1 4.1 5.1 6.1 7.1
T
A
= +85°C
T
A
= +25°C
T
A
= –40°C
13884-036
Figure 36. Conversion Gain vs. IF
IN
Frequency at Various Temperatures,
LO = 13 dBm
40
0
0.1 8.1
INPUT IP3 (dBm)
IF
IN
FREQUENCY (GHz)
5
10
15
20
25
30
35
1.1 2.1 3.1 4.1 5.1 6.1 7.1
T
A
= +85°C
T
A
= +25°C
T
A
= –40°C
13884-037
Figure 37. Input IP3 vs. IF
IN
Frequency at Various Temperatures,
LO = 13 dBm
0
–20
0.1 8.1
CONVERSION GAIN (dB)
IF
IN
FREQUENCY (GHz)
–15
–10
–5
1.1 2.1 3.1 4.1 5.1 6.1 7.1
LO = 9dBm
LO = 11dBm
LO = 13dBm
LO = 15dBm
13884-038
Figure 38. Conversion Gain vs. IF
IN
Frequency at Various LO Power Levels,
T
A
= 25°C
40
0
0.1 8.1
INPUT IP3 (dBm)
IF
IN
FREQUENCY (GHz)
5
10
15
20
25
30
35
1.1 2.1 3.1 4.1 5.1 6.1 7.1
LO = 9dBm
LO = 11dBm
LO = 13dBm
LO = 15dBm
13884-039
Figure 39. Input IP3 vs. IF
IN
Frequency at Various LO Power Levels,
T
A