M34C02
16/28
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 7. Operating Conditions (M34C02-W)
Table 8. Operating Conditions (M34C02-L)
Table 9. Operating Conditions (M34C02-R)
Table 10. Operating Conditions (M34C02-F)
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage 2.5 5.5 V
T
A
Ambient Operating Temperature –40 85 °C
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage 2.2 5.5 V
T
A
Ambient Operating Temperature –40 85 °C
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage 1.8 5.5 V
T
A
Ambient Operating Temperature –40 85 °C
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage 1.7 3.6 V
T
A
Ambient Operating Temperature 0 70 °C