MAX5927A/MAX5929A–MAX5929D
The MAX5927A/MAX5929A–MAX5929D turn off all
channels if any of the above conditions are not met.
After a fault-latched shutdown, cycle any of the ON_
inputs to unlatch and restart all channels.
Power-Sequencing Mode
Leave MODE floating to enter power-sequencing
mode. While in power-sequencing mode, the
MAX5927A/MAX5929A–MAX5929D turn on and off
each channel depending on the state of the corre-
sponding V
ON_
. To turn on a given channel:
At least one V
IN_
must exceed V
UVLO
(2.45V) for the
UVLO to startup delay (37.5ms).
All V
IN_
must exceed V
PWRRDY
(0.95V).
The corresponding V
ON_
must exceed V
ON,TH
(0.875V).
No faults can be present on any channel.
Low-Voltage, Quad, Hot-Swap
Controllers/Power Sequencers
10
____________________________________________________________________________________________________________________________________________________________________________
FAST COMP.
SLOW COMP.
FAST DISCHARGE
Q1
OUT1
2.45V
BIAS AND
REFERENCES
STARTUP
OSCILLATOR
TIMING
OSCILLATOR
CHARGE
PUMP
DEVICE CONTROL
LOGIC
V
SC, TH
V
FC, TH
R
LIM1
SENSE1
IN1
GATE1
R
SENSE1
LIM1*
R
TIM
TIM
1nF
BIAS POL*
R
LIM2
100μA
UVLO
UVLO
FAST COMP.
SLOW COMP.
FAST DISCHARGE
SLOW DISCHARGESLOW DISCHARGE
Q2
OUT2
CHARGE
PUMP
CURRENT CONTROL
AND
STARTUP LOGIC
CURRENT CONTROL
AND
STARTUP LOGIC
V
SC, TH
V
FS, TH
SENSE2
IN2
GATE2
R
SENSE2
LIM2*
100μA
STAT2STAT1
LIM3*
LIM4*
FAST COMP.
SLOW COMP.
FAST DISCHARGE
Q3
OUT3
FAULT
MANAGEMENT
OPERATION
MODE
CHARGE
PUMP
ON
INPUT
CONPARATORS
V
SC, TH
V
FS, TH
SENSE3
IN3
GATE3
R
SENSE3
R
LIM3
R
LIM4
100μA
UVLO
UVLO
FAST COMP.
SLOW COMP.
FAST DISCHARGE
SLOW DISCHARGESLOW DISCHARGE
Q4
OUT4
CHARGE
PUMP
CURRENT CONTROL
AND
STARTUP LOGIC
CURRENT CONTROL
AND
STARTUP LOGIC
V
SC, TH
V
FS, TH
SENSE4
IN4
GATE4
R
SENSE4
100μA
3mA/
50mA
3mA/
50mA
3mA/
50mA
3mA/
50mA
STAT4
STAT3*MAX5927A ONLY. LATCH* MODEON1 ON2 ON3 ON4
MAX5927A/
MAX5929A–
MAX5929D
Figure 1. Functional Diagram
MAX5927A/MAX5929A–MAX5929D
Low-Voltage, Quad, Hot-Swap
Controllers/Power Sequencers
____________________________________________________________________________________________________________________________________________________________________________
11
ON1
ON2
ON3
ON4
ANY
IN_
IN2
IN3
IN4
OUT1*
OUT2*
OUT3*
OUT4*
V
UVLO
(2.45V)
V
PWRRDY
(0.95V)
V
PWRRDY
(0.95V)
V
PWRRDY
(0.95V)
V
PWRRDY
(0.95V)
*THE OUT_ DISCHARGE RATE IS A RESULT OF NATURAL DECAY OF THE LOAD RESISTANCE AND CAPACITANCE.
Figure 2. Voltage-Tracking Timing Diagram (Provided t
D, UVLO
Requirement is Met)
MAX5927A/MAX5929A–MAX5929D
Low-Voltage, Quad, Hot-Swap
Controllers/Power Sequencers
12
____________________________________________________________________________________________________________________________________________________________________________
ON1
ON2
ON3
ON4
ANY
IN_
IN2
IN3
IN4
OUT1
OUT2
OUT3
OUT4
V
UVLO
(2.45V)
V
PWRRDY
(0.95V)
V
PWRRDY
(0.95V)
V
PWRRDY
(0.95V)
V
PWRRDY
(0.95V)
*THE OUT_ DISCHARGE RATE IS A RESULT OF NATURAL DECAY OF THE LOAD RESISTANCE AND CAPACITANCE.
*
*
*
*
Figure 3. Power-Sequencing Timing Diagram (Provided t
D, UVLO
Requirement is Met)

MAX5929AEEG+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Hot Swap Voltage Controllers Quad Hot-Swap Controller
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union