NCV8508
http://onsemi.com
15
Table 2. D
2
PAK 7−Lead Thermal RC Network Models
118 mm
2
626 mm
2
118 mm
2
626 mm
2
Cu Area
Cauer Network Foster Network
C’s C’s Units Tau Tau units
1 1.45E−06 1.45E−06 W−s/C 1.00E−07 1.00E−07 sec
2 5.55E−06 5.58E−06 W−s/C 1.00E−06 1.00E−06 sec
3 1.57E−05 1.59E−05 W−s/C 1.00E−05 1.00E−05 sec
4 5.11E−05 5.22E−05 W−s/C 0.000 0.000 sec
5 3.48E−04 5.94E−04 W−s/C 0.001 0.002 sec
6 1.07E−02 6.62E−02 W−s/C 0.006 0.029 sec
7 2.65E−02 1.55E−01 W−s/C 0.020 0.080 sec
8 0.524 0.413 W−s/C 1.43 2.63 sec
9 0.490 2.441 W−s/C 6.52 3.6 sec
10 0.843 0.410 W−s/C 104.512 95.974 sec
R’s R’s R’s R’s
1 0.089 0.089 C/W 5.25E−02 5.25E−02 C/W
2 0.210 0.208 C/W 1.14E−01 1.14E−01 C/W
3 0.637 0.624 C/W 3.59E−01 3.59E−01 C/W
4 1.899 2.107 C/W 1.5 1.9 C/W
5 1.883 2.454 C/W 2.6 3.0 C/W
6 1.398 0.952 C/W 0.1 0.1 C/W
7 0.315 0.360 C/W 1.7 0.9 C/W
8 14.348 7.042 C/W 0.1 0.1 C/W
9 5.621 20.823 C/W 7.2 4.6 C/W
10 51.986 9.649 C/W 64.8 33.3 C/W
NOTE: Bold face items in the Cauer network above, represent the package without the external thermal system. The Bold face items in
the Foster network are computed by the square root of time constant R(t) = 166 * sqrt(time(sec)). The constant is derived based
on the active area of the device with silicon and epoxy at the interface of the heat generation.
The Cauer networks generally have physical significance and may be divided between nodes to separate thermal behavior
due to one portion of the network from another. The Foster networks, though when sorted by time constant (as above) bear
a rough correlation with the Cauer networks, are really only convenient mathematical models. Cauer networks can be easily
implemented using circuit simulating tools, whereas Foster networks may be more easily implemented using mathematical
tools (for instance, in a spreadsheet program), according to the following formula:
R(t) +
n
S
i + 1
R
i
ǒ
1−e
−tń tau
i
Ǔ