LTC4009
LTC4009-1/LTC4009-2
4
4009fd
elecTrical characTerisTics
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at T
A
= 25°C. DCIN = 20V, BAT = 12V, GND = 0V unless otherwise noted. (Note 2)
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
V
IH
SHDN Input Voltage High
l
1.4 V
R
IN
SHDN Pull-Down Resistance 50
kΩ
I
DCS
DCIN Shutdown Current SHDN = 0V 215 µA
I
CLPS
CLP Shutdown Current CLP = 12V, SHDN = 0V or DCDIV = 0V
l
9 18 µA
I
LEAK-BAT
BAT Leakage Current SHDN = 0V or DCDIV = 0V,
0V ≤ CSP = CSN = BAT ≤ 20V
l
–1.5 0 1.5 µA
I
LEAK-CSN
CSN Leakage Current SHDN = 0V or DCDIV = 0V,
0V ≤ CSP = CSN = BAT ≤ 20V
l
–1.5 0 1.5 µA
I
LEAK-CSP
CSP Leakage Current SHDN = 0V or DCDIV = 0V,
0V ≤ CSP = CSN = BAT ≤ 20V
l
–1.5 0 1.5 µA
I
LEAK-SW
SW Leakage Current SHDN = 0V or DCDIV = 0V,
0V ≤ SW ≤ 20V
l
–1 0 2 µA
INTV
DD
Regulator
INTV
DD
Output Voltage No Load
l
4.85 5 5.15 V
V
DD
Load Regulation I
DD
= 20mA –0.4 –1 %
I
DD
Short-Circuit Current (Note 6) INTV
DD
= 0V 50 85 130 mA
Switching Regulator
V
CE
Charge Enable Threshold Voltage CLP – BAT, CLP Rising
C-Grade
I-Grade
l
l
65
60
100
135
140
mV
mV
I
ITH
ITH Current ITH = 1.4V –40/+90 µA
f
TYP
Typical Switching Frequency 467 550 633 kHz
f
MIN
Minimum Switching Frequency C
LOAD
= 3.3nF 20 25 kHz
DC
MAX
Maximum Duty Cycle C
LOAD
= 3.3nF 98 99 %
t
R-TG
TGATE Rise Time C
LOAD
= 3.3nF, 10% – 90% 60 110 ns
t
F-TG
TGATE Fall Time C
LOAD
= 3.3nF, 90% – 10% 50 110 ns
t
R-BG
BGATE Rise Time C
LOAD
= 3.3nF, 10% – 90% 60 110 ns
t
F-BG
BGATE Fall Time C
LOAD
= 3.3nF, 90% – 10% 60 110 ns
t
NO
TGATE, BGATE Non-Overlap Time C
LOAD
= 3.3nF, 10% – 10% 110 ns
Float Voltage Select Inputs (LTC4009-1/LTC4009-2 Only)
V
IL
Input Voltage Low 0.5 V
V
IH
Input Voltage High 3.5 V
I
IN
Input Current 0V ≤ V
IN
≤ 5V –10 10 µA
Indicator Outputs
V
OL
Output Voltage Low I
LOAD
= 100µA, PROG = 1.2V 500 mV
I
LEAK
Output Leakage SHDN = 0V, DCDIV = 0V, V
OUT
= 20V
l
–10 10 µA
I
C10
CHRG C/10 Current Sink CHRG = 2.5V
l
15 25 38 µA
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: The LTC4009C is guaranteed to meet performance specifications
over the 0°C to 85°C operating temperature range. The LTC4009I is
guaranteed to meet performance specifications over the –40°C to 125°C
operating temperature range.
Note 3: Operating junction temperature T
J
(in °C) is calculated from
the ambient temperature T
A
and the total continuous package power
dissipation P
D
(in watts) by the formula T
J
= T
A
+ (θ
JA
• PD). Refer to the
Applications Information section for details.
Note 4: All currents into device pins are positive; all currents out of device
pins are negative. All voltages are referenced to GND, unless otherwise
specified.
Note 5: This threshold is guaranteed to be satisfied if CLP = DCIN when
the LTC4009 exits shutdown.
Note 6: Output current may be limited by internal power dissipation. Refer
to the Applications Information section for details.
5
4009fd
LTC4009
LTC4009-1/LTC4009-2
Typical perForMance characTerisTics
Efficiency at DCIN = 20V, BAT = 8V
V
FB
Line Regulation
TesT circuiTs
+
1013 12
1.2085V
1.2085V
TARGET
PROG V
FB
ITH
4009 TC01
LTC4009
0.6V
EA
FROM ICL
(CLP = CLN)
+
LTC1055
+
1113 12
1.2085V
TARGET VARIES
WITH FVS0,1
PROG BAT ITH
4009 TC02
LTC4009-1
LTC4009-2
0.6V
EA
FROM ICL
(CLP = CLN)
+
LTC1055
CHARGE CURRENT (A)
0
80
EFFICIENCY (%)
POWER LOSS (mW)
85
90
95
100
100
1000
10000
0.5 1.0 1.5 2.0
4009 G01
2.5 3.0
POWER LOSS
EFFICIENCY
R
SENSE
= 33mΩ
R
IN
= 3.01k
Efficiency at DCIN = 20V, BAT = 12V
CHARGE CURRENT (A)
0
80
EFFICIENCY (%)
POWER LOSS (mW)
85
90
95
100
100
1000
10000
0.5 1.0 1.5 2.0
4009 G02
2.5 3.0
POWER LOSS
EFFICIENCY
R
SENSE
= 33mΩ
R
IN
= 3.01k
Efficiency at DCIN = 20V, BAT = 16V
CLP (V)
5
V
FB
ERROR (%)
0.02
0.06
0.10
25
4009 G04
–0.02
–0.06
0
0.04
0.08
–0.04
–0.08
–0.10
10
15
20
30
LTC4009 TEST CIRCUIT
BAT (V)
0
75
R
ON
(Ω)
100
150
175
200
10
20
25
300
4009 G05
125
5 15
225
250
275
CLP = BAT + 3V
(CLP ≥ 6V)
FBDIV R
ON
vs BAT
(T
A
= 25°C unless otherwise noted. D
IN
= SSB44, L = IHLP-2525 6.8µH)
LTC4009
LTC4009-1/LTC4009-2
6
4009fd
Typical perForMance characTerisTics
PWM Frequency vs Duty Cycle
Gate Drive Non-Overlap
Charge Current Line Regulation
Input Current Limit
Battery Load Dump
BATTERY VOLTAGE
(500mV/DIV)
LOAD
STATE
TIME (1ms/DIV)CLP = 20V
V
OUT
= 12.3V
4009 G06
DISCONNECT
RECONNECT
3A
2A
12.1V
1A
1A
DCIN (V)
5
–0.5
CHARGE CURRENT ERROR (%)
–0.4
–0.2
–0.1
0
0.5
0.2
10
15
4009 G07
–0.3
0.3
0.4
0.1
20
25
I
CHG
= 1A
I
CHG
= 2A
I
CHG
= 3A
BAT = 6V
R
SENSE
= 33mΩ
R
IN
= 3.01k
Charge Current Load Regulation
BAT (V)
11.0
CHARGE CURRENT (A)
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
–0.5
12.6
4009 G08
11.4 11.8 12.2 13.0
I
CHG
= 3A
I
CHG
= 2A
I
CHG
= 1A
DCIN = 20V
R
SENSE
= 33mΩ
R
IN
= 3.01k
SYSTEM LOAD (A)
0
CURRENT (A)
0.5
1.0
1.5
1.5
2.5
4009 G09
0
–0.5
–1.0
0.5 1.0 2.0
2.0
2.5
3.0
I
IN
I
CHG
ICL STATE
2.5A BULK CHARGE
2.1A INPUT CURRENT LIMIT
PWM Soft-Start
I
CHG
2A/DIV
TIME (500µs/DIV)
4009 G10
ITH
1V/DIV
PROG
1V/DIV
SHDN
5V/DIV
TIME (80ns/DIV)
EXTERNAL FET DRIVE (1V/DIV)
4009 G11
TGATE
BGATE
DUTY CYCLE (%)
0
0
PWM FREQUENCY (kHz)
100
200
300
400
500
600
20 40 60 80
4009 G12
100
CLP = 6V
CLP = 12V
CLP = 20V
CLP = 25V
I
CHG
= 750mA
(T
A
= 25°C unless otherwise noted. D
IN
= SSB44, L = IHLP-2525 6.8µH)
Charge Current Accuracy
BAT (V)
0
5
4
3
2
1
0
–1
–2
12 20
4009 G15
4 8 162 14 226 10 18 24
CHARGE CURRENT ERROR (%)
DCIN = 24V
R
PROG
= 35.7k
R
SENSE
= 33mΩ
R
IN
= 3.01k
DCIN = 12V
R
PROG
= 26.7k

LTC4009IUF-2#TRPBF

Mfr. #:
Manufacturer:
Analog Devices / Linear Technology
Description:
Battery Management High Efficiency, Multi-Chemistry QFN Battery Charger
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union