Real Time Clock Operation
The Real Time Clock (RTC) uses an external 32.768kHz
quartz crystal to maintain an accurate internal representation
of the second, minute, hour, day, date, month and year. The
RTC has leap-year correction. The clock also corrects for
months having fewer than 31 days and has a bit that controls
24 hour or AM/PM format. When the ISL12027 powers up
after the loss of both V
DD
and V
BAT
, the clock will not
operate until at least one byte is written to the clock register.
Reading the Real Time Clock
The RTC is read by initiating a Read command and
specifying the address corresponding to the register of the
Real Time Clock. The RTC Registers can then be read in a
Sequential Read Mode. Since the clock runs continuously
and read takes a finite amount of time, there is a possibility
that the clock could change during the course of a read
operation. In this device, the time is latched by the read
command (falling edge of the clock on the ACK bit prior to
RTC data output) into a separate latch to avoid time changes
during the read operation. The clock continues to run.
Alarms occurring during a read are unaffected by the read
operation.
Writing to the Real Time Clock
The time and date may be set by writing to the RTC
registers. RTC Register should be written ONLY with Page
Write. To avoid changing the current time by an uncompleted
write operation, write to the all 8 bytes in one write operation.
When writing the RTC registers, the new time value is
loaded into a separate buffer at the falling edge of the clock
during the Acknowledge. This new RTC value is loaded into
the RTC Register by a stop bit at the end of a valid write
sequence. An invalid write operation aborts the time update
procedure and the contents of the buffer are discarded. After
a valid write operation, the RTC will reflect the newly loaded
data beginning with the next “one second” clock cycle after
the stop bit is written. The RTC continues to update the time
while an RTC register write is in progress and the RTC
continues to run during any non-volatile write sequences.
Accuracy of the Real Time Clock
The accuracy of the Real Time Clock depends on the
accuracy of the quartz crystal that is used as the time base
for the RTC. Since the resonant frequency of a crystal is
temperature dependent, the RTC performance will also be
dependent upon temperature. The frequency deviation of
the crystal is a function of the turnover temperature of the
crystal from the crystal’s nominal frequency. For example, a
>20ppm frequency deviation translates into an accuracy of
>1 minute per month. These parameters are available from
the crystal manufacturer. Intersil’s RTC family provides on-
chip crystal compensation networks to adjust
load-capacitance to tune oscillator frequency from -34ppm to
+80ppm when using a 12.5pF load crystal. For more detailed
information see “Application Section” on page 22.
Clock/Control Registers (CCR)
The Control/Clock Registers are located in an area separate
from the EEPROM array and are only accessible following a
slave byte of “1101111x” and reads or writes to addresses
[0000h:003Fh]. The clock/control memory map has memory
addresses from 0000h to 003Fh. The defined addresses are
described in Table 2. Writing to and reading from the
undefined addresses are not recommended.
CCR Access
The contents of the CCR can be modified by performing a
byte or a page write operation directly to any address in the
CCR. Prior to writing to the CCR (except the status register),
however, the WEL and RWEL bits must be set using a three
step process (see “Writing to the Clock/Control Registers” on
page 14).
The CCR is divided into 5 sections. These are:
1. Alarm 0 (8 bytes; non-volatile)
2. Alarm 1 (8 bytes; non-volatile)
3. Control (5 bytes; non-volatile)
4. Real Time Clock (8 bytes; volatile)
5. Status (1 byte; volatile)
Each register is read and written through buffers. The
non-volatile portion (or the counter portion of the RTC) is
updated only if RWEL is set and only after a valid write
operation and stop bit. A sequential read or page write
operation provides access to the contents of only one
section of the CCR per operation. Access to another section
requires a new operation. A read or write can begin at any
address in the CCR.
It is not necessary to set the RWEL bit prior to writing the
status register. Section 5 (status register) supports a single
byte read or write only. Continued reads or writes from this
section terminates the operation.
The state of the CCR can be read by performing a random
read at any address in the CCR at any time. This returns the
contents of that register location. Additional registers are
read by performing a sequential read. The read instruction
latches all Clock registers into a buffer, so an update of the
clock does not change the time being read. A sequential
read of the CCR will not result in the output of data from the
memory array. At the end of a read, the master supplies a
stop condition to end the operation and free the bus. After a
read of the CCR, the address remains at the previous
address +1 so the user can execute a current address read
of the CCR and continue reading the next Register.
Real Time Clock Registers (Volatile)
SC, MN, HR, DT, MO, YR: Clock/Calendar Registers
These registers depict BCD representations of the time. As
such, SC (Seconds) and MN (Minutes) range from 00 to 59,
HR (Hour) is 1 to 12 with an AM or PM indicator (H21 bit) or
ISL12027, ISL12027A
11
FN8232.8
August 12, 2010
0 to 23 (with MIL = 1), DT (Date) is 1 to 31, MO (Month) is 1
to 12, YR (Year) is 0 to 99.
DW: Day of the Week Register
This register provides a Day of the Week status and uses
three bits DY2 to DY0 to represent the seven days of the
week. The counter advances in the cycle 0-1-2-3-4-5-6-0-1-
2-… The assignment of a numerical value to a specific day
of the week is arbitrary and may be decided by the system
software designer. The default value is defined as ‘0’.
Y2K: Year 2000 Register
Can have value 19 or 20. As of the date of the introduction of
this device, there would be no real use for the value 19 in a
true real time clock, however.
24 Hour Time
If the MIL bit of the HR register is 1, the RTC uses a 24-hour
format. If the MIL bit is 0, the RTC uses a 12-hour format and
H21 bit functions as an AM/PM indicator with a ‘1’,
representing PM. The clock defaults to standard time with
H21 = 0.
Leap Years
Leap years add the day February 29 and are defined as
those years that are divisible by 4.
Status Register (SR) (Volatile)
The Status Register is located in the CCR memory map at
address 003Fh. This is a volatile register only and is used to
control the WEL and RWEL write enable latches, read power
status and two alarm bits. This register is separate from both
the array and the Clock/Control Registers (CCR).
BAT: Battery Supply
This bit set to “1” indicates that the device is operating from
V
BAT
, not V
DD
. It is a read-only bit and is set/reset by
hardware (ISL12027 internally). Once the device begins
operating from V
DD
, the device sets this bit to “0”.
AL1, AL0: Alarm Bits
These bits announce if either alarm 0 or alarm 1 match the
real time clock. If there is a match, the respective bit is set to
‘1’. The falling edge of the last data bit in a SR Read
operation resets the flags. Note: Only the AL bits that are set
when an SR read starts will be reset. An alarm bit that is set
by an alarm occurring during an SR read operation will
remain set after the read operation is complete.
OSCF: Oscillator Fail Indicator
This bit is set to “1” if the oscillator is not operating, or is
operating but has clock jitter which does not affect the
accuracy of RTC counting. The bit is set to “0” if the oscillator
is functioning and does not have clock jitter. This bit is read
only, and is set/reset by hardware.
RWEL: Register Write Enable Latch
This bit is a volatile latch that powers up in the LOW
(disabled) state. The RWEL bit must be set to “1” prior to any
writes to the Clock/Control Registers. Writes to RWEL bit do
not cause a non-volatile write cycle, so the device is ready
for the next operation immediately after the stop condition. A
write to the CCR requires both the RWEL and WEL bits to be
set in a specific sequence.
WEL: Write Enable Latch
The WEL bit controls the access to the CCR during a write
operation. This bit is a volatile latch that powers up in the
LOW (disabled) state. While the WEL bit is LOW, writes to
the CCR address will be ignored, although acknowledgment
is still issued. The WEL bit is set by writing a “1” to the WEL
bit and zeroes to the other bits of the Status Register. Once
set, WEL remains set until either reset to 0 (by writing a “0”
to the WEL bit and zeroes to the other bits of the Status
Register) or until the part powers up again. Writes to WEL bit
do not cause a non-volatile write cycle, so the device is
ready for the next operation immediately after the stop
condition.
RTCF: Real Time Clock Fail Bit
This bit is set to a “1” after a total power failure. This is a read
only bit that is set by hardware (ISL12027 internally) when
the device powers up after having lost all power to the device
(both V
DD
and V
BAT
go to 0V). The bit is set regardless of
whether V
DD
or V
BAT
is applied first. The loss of only one of
the supplies does not set the RTCF bit to “1”. On power up
after a total power failure, all registers are set to their default
states and the clock will not increment until at least one byte
is written to the clock register. The first valid write to the RTC
section after a complete power failure resets the RTCF bit to
“0” (writing one byte is sufficient).
Unused Bits:
Bit 3 in the SR is not used, but must be zero. The Data Byte
output during a SR read will contain a zero in this bit
location.
TABLE 1. STATUS REGISTER (SR)
ADDR 7 6 5 4 3 2 1 0
003Fh BAT AL1 AL0 OSCF 0 RWEL WEL RTCF
Default 0 0 0 0 0 0 0 1
ISL12027, ISL12027A
12
FN8232.8
August 12, 2010
TABLE 2. CLOCK/CONTROL MEMORY MAP
ADDR. TYPE
REG
NAME
BIT
RANG
E
ISL12027
DEFAULT
ISL12027A
DEFAULT
76543210
003F Status SR BAT AL1 AL0 OSCF
0 RWEL WEL RTCF 01h 01h
0037 RTC
(SRAM)
Y2K
0 0 Y2K21 Y2K20 Y2K13 0 0 Y2K10 19/20 20h 20h
0036 DW
0 0 0 0 0 DY2 DY1 DY0 0-6 00h 00h
0035 YR Y23 Y22 Y21 Y20 Y13 Y12 Y11 Y10 0-99 00h 00h
0034 MO
0 0 0 G20 G13 G12 G11 G10 1-12 00h 00h
0033 DT
0 0 D21 D20 D13 D12 D11 D10 1-31 01h 01h
0032 HR MIL
0 H21 H20 H13 H12 H11 H10 0-23 00h 00h
0031 MN
0 M22 M21 M20 M13 M12 M11 M10 0-59 00h 00h
0030 SC
0 S22 S21 S20 S13 S12 S11 S10 0-59 00h 00h
0014 Control
(EEPROM
)
PWR SBIB BSW
0 0 0 VTS2 VTS1 VTS0 4Xh 0Xh
0013 DTR
0 0 0 0 0 DTR2 DTR1 DTR0 00h 00h
0012 ATR
0 0 ATR5ATR4ATR3ATR2ATR1ATR0 00h00h
0011 INT IM AL1E AL0E 0 0
0 0 0 00h 00h
0010 BL BP2 BP1 BP0 WD1 WD0
0 0 0 18h 18h
000F Alarm1
(EEPROM
)
Y2K1
0 0 A1Y2K21 A1Y2K20 A1Y2K13 0 0 A1Y2K10 19/20 20h 20h
000E DWA1 EDW1
0 0 0 0 DY2 DY1 DY0 0-6 00h 00h
000D YRA1 Unused - Default = RTC Year value (No EEPROM) - Future expansion
000C MOA1 EMO1
0 0 A1G20 A1G13 A1G12 A1G11 A1G10 1-12 00h 00h
000B DTA1 EDT1
0 A1D21 A1D20 A1D13 A1D12 A1D11 A1D10 1-31 00h 00h
000A HRA1 EHR1
0 A1H21 A1H20 A1H13 A1H12 A1H11 A1H10 0-23 00h 00h
0009 MNA1 EMN1 A1M22 A1M21 A1M20 A1M13 A1M12 A1M11 A1M10 0-59 00h 00h
0008 SCA1 ESC1 A1S22 A1S21 A1S20 A1S13 A1S12 A1S11 A1S10 0-59 00h 00h
0007 Alarm0
(EEPROM
)
Y2K0
0 0 A0Y2K21 A0Y2K20 A0Y2K13 0 0 A0Y2K10 19/20 20h 20h
0006 DWA0 EDW0
0 0 0 0 DY2 DY1 DY0 0-6 00h 00h
0005 YRA0 Unused - Default = RTC Year value (No EEPROM) - Future expansion
0004 MOA0 EMO0
0 0 A0G20 A0G13 A0G12 A0G11 A0G10 1-12 00h 00h
0003 DTA0 EDT0
0 A0D21 A0D20 A0D13 A0D12 A0D11 A0D10 1-31 00h 00h
0002 HRA0 EHR0
0 A0H21 A0H20 A0H13 A0H12 A0H11 A0H10 0-23 00h 00h
0001 MNA0 EMN0 A0M22 A0M21 A0M20 A0M13 A0M12 A0M11 A0M10 0-59 00h 00h
0000 SCA0 ESC0 A0S22 A0S21 A0S20 A0S13 A0S12 A0S11 A0S10 0-59 00h 00h
NOTE: (Shaded cells indicate that NO other value is to be written to that bit. X indicates the bits are set according to the product variation, see device
“Ordering Information” on page 2).
ISL12027, ISL12027A

ISL12027AIB27Z-T

Mfr. #:
Manufacturer:
Renesas / Intersil
Description:
Real Time Clock REAL TIME CLK/CLNDR W/EEPROM 2 63VSET
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union