5
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (Option 060)
Characteristic
Description Symbol HCPL-2533 Unit
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms I-IV
for rated mains voltage ≤ 600 V rms I-III
Climatic Classication 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
630 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test V
PR
1181 V
peak
with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample Test, V
PR
945 V
peak
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage V
IOTM
6000 V
peak
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure.)
Case Temperature T
S
175 °C
Input Current** I
S,INPUT
230 mA
Output Power** P
S,OUTPUT
600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
> 10
9
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer's Catalog, under Product Safety Regulations section,
IEC/EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test proles.
** Refer to the following gure for dependence of P
S
and I
S
on ambient temperature.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
OUTPUT POWER – P
S
, INPUT CURRENT – I
S
0
0
T
S
– CASE TEMPERATURE – °C
200
700
400
25
800
50 75 100
200
150 175
P
S
(mW)
I
S
(mA)
125
100
300
600
500