NCP1380
www.onsemi.com
13
APPLICATION INFORMATION
The NCP1380 implements a standard current−mode
architecture operating in quasi−resonant mode. Due to a
proprietary circuitry, the controller prevents
valley−jumping instability and steadily locks out in selected
valley as the power demand goes down. Once the fourth
valley is reached, the controller continues to reduce the
frequency further down, offering excellent efficiency over
a wide operating range. Thanks to a fault timer combined to
an OPP circuitry, the controller is able to efficiently limit the
output power at high−line.
Quasi−Resonance Current−mode operation:
implementing quasi−resonance operation in peak
current−mode control, the NCP1380 optimizes the
efficiency by switching in the valley of the MOSFET
drain−source voltage. Thanks to a proprietary circuitry,
the controller locks−out in a selected valley and
remains locked until the output loading significantly
changes. When the load becomes lighter, the controller
jumps into the next valley. It can go down to the 4
th
valley if necessary. Beyond this point, the controller
reduces its switching frequency by freezing the peak
current setpoint. During quasi−resonance operation, in
case of very damped valleys, a 5.5 ms timer emulates
the missing valleys.
Frequency reduction in light−load conditions: when
the 4
th
valley is left, the controller reduces the
switching frequency which naturally improves the
standby power by a reduction of all switching losses.
Overpower protection (OPP): When the voltage on
ZCD pin swings in flyback polarity, a direct image if
the input voltage is applied on ZCD pin. We can thus
reduce the peak current depending of V
ZCD
during the
on−time.
Internal soft−start: A soft−start precludes the main
power switch from being stressed upon startup. Its
duration is fixed and equal to 4 ms.
Fault input (A and B versions): By combining a dual
threshold on the Fault pin, the controller allows the
direct connection of an NTC to ground plus a zener
diode to a monitored voltage. In case the pin is brought
below the OTP threshold by the NTC or above the OVP
threshold by the zener diode, the circuit permanently
latches−off and V
CC
is clamped to 7.2 V.
Fault input (C and D versions): The C and D versions
of NCP1380 include a brown−out circuit which safely
stops the controller in case the input voltage is too low.
Restart occurs via a complete startup sequence (latch
reset and soft−start). During normal operation, the
voltage on this pin is clamped to V
clamp
to give enough
room for OVP detection. If the voltage on this pin
increases above 2.5 V, the part latches−off.
Short−circuit protection: Short−circuit and especially
over−load protections are difficult to implement when a
strong leakage inductance between auxiliary and power
windings affects the transformer (where the auxiliary
winding level does not properly collapse in presence of
an output short). Here, when the internal 0.8 V
maximum peak current limit is activated, the timer
starts counting up. If the fault disappears, the timer
counts down. If the timer reaches completion while the
error flag is still present, the controller stops the pulses.
This protection is latched on A and C version (the user
must unplug and re−plug the power supply to restart the
controller) and auto−recovery on B and D versions (if
the fault disappears, the SMPS automatically resumes
operation). In addition, all versions feature a winding
short−circuit protection, that senses the CS signal and
stops the controller if V
CS
reaches 1.5 x V
ILIM
(after a
reduced LEB of t
BCS
). This additional comparator is
enabled only during the main LEB duration t
LEB
, for
noise immunity reason.
NCP1380 OPERATING MODES
NCP1380 has two operating mode: quasi−resonant
operation and VCO operation for the frequency foldback.
The operating mode is fixed by the FB voltage as
portrayed by Figure 26:
Quasi−resonant operation occurs for FB voltage higher
than 0.8 V (FB decreasing) or higher than 1.4 V (FB
increasing) which correspond to high output power and
medium output power. The peak current is variable and
is set by the FB voltage divided by 4.
Frequency foldback or VCO mode occurs for FB
voltage lower than 0.8 V (FB decreasing) or lower than
1.4 V (FB increasing). This corresponds to low output
power.
During VCO mode, the peak current decreases down to
17.5% of its maximum value and is then frozen. The
switching frequency is variable and decreases as the
output load decreases.
The switching frequency is set by the end of charge of
the capacitor connected to the C
T
pin. This capacitor is
charged with a constant current source and the
capacitor voltage is compared to an internal threshold
fixed by FB voltage. When this capacitor voltage
reaches the threshold the capacitor is rapidly discharged
down to 0 V and a new period start.
NCP1380
www.onsemi.com
14
Figure 26. Operating Valley According to FB Voltage
VALLEY DETECTION AND SELECTION
The valley detection is done by monitoring the voltage of
the auxiliary winding of the transformer. A valley is detected
when the voltage on pin 1 crosses down the 55 mV internal
threshold. When a valley is detected, an internal counter is
incremented. The operating valley (1
st
, 2
nd
, 3
rd
or 4
th
) is
determined by the FB voltage as shown by Figure 26.
FB
Ct
ICt
+
+
ZCD
Laux
10 V
ES D
Vth
DRV
3 us puls e
dem a g
S
R
Q
Q
leakage
blanking
VDD
VDD
Ct
Discharge
Rpullup
DRV
LOGIC BLOCK
VDD
Time Out CS comparator
V
FBth
V
FB
Ct setpoint
Figure 27. Valley Detection Circuit
NCP1380
www.onsemi.com
15
As the output load decreases (FB voltage decreases), the
valleys are incremented from the first to the fourth. When
the fourth valley is reached, if FB voltage further decreases
below 0.8 V, the controller enters VCO mode.
During VCO operation, the peak current continues to
decrease until it reaches 17.5% of the maximum peak
current: the switching frequency expands to deliver the
necessary output power. This allows achieving very low
standby power consumption.
The Figure 28 shows a simulation case where the output
current of a 19 V, 60 W adapter decreases from 2.8 A to
0.1 A. No instability is seen during the valley transitions
(Figures 29, 30, 31 and 32)
Figure 28. Output Load is Decreased from 2.8 A Down to 100 mA at 120 Vdc Input Voltage