GU128X32D-7003
- 20 -
7.1.26 <Function 11H> US ( a n p t1 t2 c (Display Blink)
Code: 1FH 28H 61H 11H p t1 t2 c
n: Classify command
p: Blink pattern
t1: Normal display time
t2: Brank or Reverse display time
c: Number of reptition
Definable area: n = 11H
0 ≦ p ≦ 2
p=0: Nomal display.
P=1: Repeat blink display with nomal and Brank display
P=2: Repeat blink display with nomal and Reverse display
1 ≦ t1 ≦ 255
1 ≦ t2 ≦ 255
1 ≦ c ≦ 255
Function: Blink display action Blink pattern specifed by “p”.
Time specified by “t1” , “t2”, and repeat Blink display
A : t1 X approx.14msec Nomal display
B: t2 X approx. 14msec Brank or Reverse display
This command does not affect to display memory.
If c=0 is specified, brink display is repeated until when c=1 – 255 or Initialize command is specified,
and the command/data execution is continued during display blinking.
If c=1 – 255 is specified, brink display is repeated 1-255 times, and the command/data execution
is stopped. After display blinking is ended, return to nomal display and command/data execution
is re-started.
7.1.27 <Function 12H> US ( a n p (Screen saver)
Code: 1FH 28H 61H 40H p
n: Classify command
p: Screen saver mode
Definable area: n = 40H
0 ≦ p ≦ 4
p=0: Power OFF (All dot OFF, Power save mode)
p=1: Power ON (All dot ON)
p=2: All dot OFF
p=3: All dot ON
p=4: Repeat blink display with nomal and Reverse display (Nomal :2sec., Reverse:2sec.)
Function: Control Power ON or OFF, and Start Screen saver mode.
p=0~1 : Control Power ON or OFF. This is applied until this command is re-specified
p=2~4 : Start Screen saver mode. This command is canceled if next any data is inputted during
screen saver mode, and return to the previous display condition before screen saver mode
specified.