13
FN8131.3
December 9, 2015
CS/WDI vs RESET/RESET Timing
RESET
Output Timing
SYMBOL PARAMETER MIN TYP MAX UNIT
V
TRIP
Reset Trip Point Voltage, X5323-4.5A, X5323-4.5A 4.5 4.63 4.75 V
Reset Trip Point Voltage, X5323, X5325 4.25 4.38 4.5 V
Reset Trip Point Voltage, X5323-2.7A, X5325-2.7A 2.85 2.92 3.0 V
Reset Trip Point Voltage, X5323-2.7, X5325-2.7 2.55 2.63 2.7 V
V
TH
V
TRIP
Hysteresis (HIGH to LOW vs LOW to HIGH V
TRIP
Voltage) 20 mV
t
PURST
Power-up Reset Time-Out 100 200 280 ms
t
RPD
(Note 5) V
CC
Detect To Reset/Output 500 ns
t
F
(Note 5) V
CC
Fall Time 100 µs
t
R
(Note 5) V
CC
Rise Time 100 µs
V
RVALID
Reset Valid V
CC
1V
NOTE:
5. This parameter is periodically sampled and not 100% tested.
CS/WDI
t
CST
RESET
t
WDO
t
RST
t
WDO
t
RST
RESET
RESET/RESET Output Timing
SYMBOL PARAMETER MIN TYP MAX UNIT
t
WDO
Watchdog Time-Out Period
WD1 = 1, WD0 = 0 100 200 300 ms
WD1 = 0, WD0 = 1 450 600 800 ms
WD1 = 0, WD0 = 0 1 1.4 2 s
t
CST
CS Pulse Width to Reset the Watchdog 400 ns
t
RST
Reset Time-Out 100 200 300 ms
X5323, X5325
14
FN8131.3
December 9, 2015
V
TRIP
Set Conditions
V
TRIP
Reset Conditions
SCK
SI
V
P
V
P
CS
t
VPS
t
VPH
t
P
t
VPS
t
VPH
t
RP
t
VPO
t
VPO
t
TSU
t
THD
V
TRIP
V
CC
SCK
SI
V
CC
V
P
CS
t
VPS
t
VPH
t
P
t
VPS
t
VP1
t
RP
t
VPO
t
VPO
V
CC
*
*V
CC
> PROGRAMMED V
TRIP
V
TRIP
Programming Specifications V
CC
= 1.7 to 5.5V; Temperature = 0°C to +70°C.
PARAMETER DESCRIPTION MIN MAX UNIT
t
VPS
SCK V
TRIP
Program Voltage Set-up Time 1 µs
t
VPH
SCK V
TRIP
Program Voltage Hold Time 1 µs
t
P
V
TRIP
Program Pulse Width s
t
TSU
V
TRIP
Level Set-up Time 10 µs
t
THD
V
TRIP
Level Hold (Stable) Time 10 ms
X5323, X5325
15
FN8131.3
December 9, 2015
t
WC
V
TRIP
Write Cycle Time 10 ms
t
RP
V
TRIP
Program Cycle Recovery Period (Between Successive Programming Cycles) 10 ms
t
VPO
SCK V
TRIP
Program Voltage Off-Time Before Next Cycle 0 ms
V
P
Programming Voltage 15 18 V
V
TRAN
V
TRIP
Programed Voltage Range 1.7 5.0 V
V
ta1
Initial V
TRIP
Program Voltage Accuracy (V
CC
Applied-V
TRIP
) (Programmed at +25°C) -0.1 +0.4 V
V
ta2
Subsequent V
TRIP
Program Voltage Accuracy [(V
CC
Applied-V
ta1
)-V
TRIP
] (Programmed at +25°C) -25 +25 mV
V
tr
V
TRIP
Program Voltage Repeatability (Successive Program Operations; Programmed at +25°C) -25 +25 mV
V
tv
V
TRIP
Program Variation After Programming (0°C to +75°C; Programmed at +25°C) -25 +25 mV
NOTE:
6. V
TRIP
programming parameters are periodically sampled and are not 100% tested.
V
TRIP
Programming Specifications V
CC
= 1.7 to 5.5V; Temperature = 0°C to +70°C. (Continued)
PARAMETER DESCRIPTION MIN MAX UNIT
Typical Performance Curves
FIGURE 10. V
CC
SUPPLY CURRENT vs TEMPERATURE (I
SB
) FIGURE 11. T
WDO
vs VOLTAGE/TEMPERATURE (WD1, 0 = 1, 1)
FIGURE 12. V
TRIP
vs TEMPERATURE (PROGRAMMED AT +25°C) FIGURE 13. T
WDO
vs VOLTAGE/TEMPERATURE (WD1, 0 = 1, 0)
18
16
14
12
10
8
6
4
2
0
-40 25 90
TEMPERATURE (°C)
ISB (µA)
WATCHDOG TIMER OFF (V
CC
= 3V, 5V)WATCHDOG TIMER OFF (V
CC
= 3V, 5V)
WATCHDOG TIMER ON (V
CC
= 5V)
WATCHDOG TIMER ON (V
CC
= 5V)
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
1.7 2.4 3.1 3.8 4.5 5.2
+90°C
+25°C
-40°C
RESET (s)
VOLTAGE (V)
5.025
5.000
4.975
3.525
3.500
3.475
2.525
2.500
2.475
025 85
VOLTAGE (V)
TEMPERATURE (°C)
V
TRIP
= 5V
V
TRIP
= 3.5V
V
TRIP
= 2.5V
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
1.7 5.2
RESET (s)
VOLTAGE (V)
2.4 3.1 3.8 4.5
+90°C
+25°C
-40°C
X5323, X5325

X5325S8IZ-2.7A

Mfr. #:
Manufacturer:
Renesas / Intersil
Description:
Supervisory Circuits CPU SUP/WDT 32K SPI EE RST HI 2 7-3 6V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union