© PHOENIX CONTACT - 10/2006
7252_en_02
AUTOMATIONWORX
IB IL AI 4/EF ...
Data Sheet
1 Description
The terminal is designed for use within an Inline station. It is
used to acquire analog voltage or current signals.
Features
Four differential analog signal inputs for the connection
of either voltage or current signals
Connection of sensors in 2, 3 or 4-wire technology
Three current measuring ranges:
0 mA to 20 mA, ±20 mA, 4 mA to 20 mA
Four voltage measuring ranges:
0 V to 10 V, ±10 V, 0 V to 5 V, ±5 V
Sensor supply with channel-specific integrated short-
circuit and overload protection
Measured values can be represented in four different
formats
Mean-value generation of measured values
Process data update of all channels in 1 ms, maximum
Bus-synchronous provision of input values
High level of accuracy
Parameterization and diagnostics via PCP
Channels are configured independently of one another
using the bus
Resolution depends on the representation format and
the measuring range
Diagnostic indicators
Inline Terminal
With Four Differential Analog Input Channels
This data sheet is only valid in association with the IB IL SYS PRO UM E user manual or the Inline system
manual for your bus system.
The product versions differ in the scope of supply and the transmission speed (see "Ordering Data" on page 3).
The function is identical. Differing technical data is indicated. For greater clarity, the order designation
IB IL AI 4/EF is used throughout this document.
Make sure you always use the latest documentation.
It can be downloaded at www.download.phoenixcontact.com
.
A conversion table is available on the Internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
This data sheet is valid for all products listed under "Ordering Data" on page 3.
T
R
U
is
D
AI 4/E
S
IB IL AI 4/EF ...
7252_en_02 PHOENIX CONTACT 2
Table of Contents
1 Description.................................................................................................................................. 1
2 Ordering Data ............................................................................................................................. 3
3 Technical Data............................................................................................................................ 4
4 Local Diagnostic and Status Indicators and Terminal Point Assignment ................................... 8
4.1 Function Identification .................................................................................................................................... 8
4.2 Local Diagnostic and Status Indicators.......................................................................................................... 8
4.3 Terminal Point Assignment for Each Connector ............................................................................................ 8
5 Installation Instructions ............................................................................................................... 8
6 Internal Circuit Diagram.............................................................................................................. 9
7 Electrical Isolation......................................................................................................................10
8 Connection Notes......................................................................................................................10
9 Connection Examples................................................................................................................10
10 Configuration and Analog Values..............................................................................................13
11 Programming Data/Configuration Data........................................................................................................ 13
11.1 INTERBUS................................................................................................................................................... 13
11.2 Other Bus Systems ...................................................................................................................................... 13
12 Assignment of the Process Data to the Terminal Points for the
"Read Analog Value" and "Configure Device and Read Analog Value" Commands
.................... 13
13 Process Data .............................................................................................................................14
14 OUT Process Data Words .........................................................................................................15
14.1 Output Word OUT1 (Control Word).............................................................................................................. 15
14.2 Output Words OUT2 to OUT5 (Configuration)............................................................................................. 16
14.3 Parameters for Configuration....................................................................................................................... 16
15 IN Process Data Words .............................................................................................................17
15.1 Input Word IN1 (Status Word)...................................................................................................................... 17
15.2 Input Words IN2 to IN5................................................................................................................................. 17
16 Formats for the Representation of Measured Values (IN2 to IN5) ............................................18
16.1 Format: "IB IL" (Default Setting)................................................................................................................... 18
16.2 Format: "IB ST" ............................................................................................................................................ 19
16.3 Format: "S7-Compatible" ............................................................................................................................. 20
16.4 Format: "Standardized Representation"....................................................................................................... 21
16.5 Supported Error Codes for the "IB IL" and "Standardized Display" Formats ............................................... 22
17 PCP Communication .................................................................................................................22
17.1 Object Dictionary.......................................................................................................................................... 22
17.2 Object Description........................................................................................................................................ 23
18 Diagnostics ................................................................................................................................25
IB IL AI 4/EF ...
7252_en_02 PHOENIX CONTACT 3
2 Ordering Data
Terminals
Description Type Order No. Pcs./Pck.
Terminal with four analog input channels;
transmission speed of 500 kbps;
including accessories (connectors and labeling fields)
IB IL AI 4/EF-PAC 2878447 1
Terminal with four analog input channels;
transmission speed of 500 kbps; without accessories
IB IL AI 4/EF 2863478 1
Terminal with four analog input channels;
transmission speed of 2 Mbps;
including accessories (connectors and labeling fields)
IB IL AI 4/EF 2MBD-PAC 2878641 1
Terminal with four analog input channels;
transmission speed of 2 Mbps; without accessories
IB IL AI 4/EF 2MBD 2878544 1
The listed connector is needed for the complete fitting of the IB IL AI 4/EF terminal.
Accessories
Description Type Order No. Pcs./Pck.
Connector with shield connection (green, without color print) IB IL SCN-6 SHIELD 2726353 5
Documentation
Description Type Order No. Pcs./Pck.
User manual:
"Configuring and Installing the INTERBUS Inline Product Range"
IB IL SYS PRO UM E 2743048 1
User manual:
"Automation Terminals of the Inline Product Range"
IL SYS INST UM E 2698737 1

2878447

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Controllers IB IL AI 4/EF-PAC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet