Table 8. STANDARD COMMAND CODES (PART 2)
Command
Code
R/W Default Description # Bytes Comment
0x7A R 0x00 STATUS
VOUT
1
Bit Name Description
7 VOUT_OVER
VOLTAGE
FAULT
This bit gets set whenever an OVP event
takes place.
6 VOUT_OVER
VOLTAGE
WARNING
This bit gets set whenever the measured
output voltage goes above its
power-good limit.
(Reserved for future use.)
5 VOUT_
UNDER
VOLTAGE
WARNING
This bit gets set whenever the measured
output voltage goes below its
power*good limit.
(Reserved for future use.)
4 VOUT_UNDE
RVOLTAGE
FAULT
This bit gets set whenever an UVP event
takes place.
3 (Reserved for future use.)
2 (Reserved for future use.)
1 (Reserved for future use.)
0 (Reserved for future use.)
0x7B R 0x00 STATUS
IOUT
1
Bit Name Description
7 IOUT_OVER
CURRENT
FAULT
This bit gets set if the NCP81233 turns off
due to an OCP Event
6 (Reserved for future use.)
5 IOUT_OVER
CURRENT
WARNING
This bit gets set if IOUT exceeds its
programmed high warning limit.
(Reserved for future use.)
4 (Reserved for future use.)
3 (Reserved for future use.)
2 (Reserved for future use.)
1 (Reserved for future use.)
0 (Reserved for future use.)
0x7E R 0x00 STATUS
CML
1
Bit Name Description
7 INVALID
COMMAND
Invalid or unsupported command is
received. (Reserved for future use.)
6 INVALID
DATA
Invalid or unsupported data is received.
(Reserved for future use.)
5 PEC_FAULT PEC failed. (Reserved for future use.)
4 (Reserved for future use.)
3 (Reserved for future use.)
2 (Reserved for future use.)
1 OTHERS A communication fault other than the
ones listed has occurred. (Reserved for
future use.)
0 (Reserved for future use.)