NCP81233
www.onsemi.com
25
TABLE 7. STANDARD COMMAND CODES (PART 1) (continued)
Command
Code
Comment
#
Bytes
DescriptionDefaultR/W
0x20 R 0x20 Vout_Mode 1 The NCP81233 supports VID mode for programming the output
voltage.
0x21 R/W 0x0000 Vout_Command 2 Sets the output voltage using VID in low byte.
0x24 R/W 0x00FF Vout_Max 2 Sets maximum output voltage (VID data format).
(Reserved for future use.)
0xA4 R/W 0x0000 Vout_Min 2 Sets minimum output voltage (VID data format).
(Reserved for future use.)
0x60 R/W 0x0000 TON_DELAY 2 Sets the delay time, in ms, from the end of system reset until the
output voltage starts to rise. The lowest 4 bits of the high byte is
valid, i.e.
0x0000 = 0ms
0x0100 = 1ms
0x0200 = 2ms
0x0F00 = 15ms
0x78 R 0x00 STATUS BYTE 1
Bit Name Description
7 BUSY A fault was declared because
the NCP81233 was busy and
unable to respond
6 OFF This bit is set whenever the
NCP81233 is not switching
5 VOUT_OV This bit gets set whenever the
NCP81233 goes into OVP (Abs
OVP and/or Normal OVP) mode.
4 IOUT_OC This bit gets set whenever the
NCP81233 turns off due to an
over current event.
3 VIN_UV Not supported.
2 OT This bit gets set whenever the
NCP81233 turns off due to an
over temperature event.
1 CML This bit gets set whenever a
communications or logic fault
has occurred.
0 None of the
Above
A fault has occurred which is not
one of the above.
NCP81233
www.onsemi.com
26
TABLE 7. STANDARD COMMAND CODES (PART 1) (continued)
Command
Code
Comment
#
Bytes
DescriptionDefaultR/W
0x79 R 0x0000 STATUS WORD 2
Byte Bit Name Description
Low
7 BUSY A fault was declared because
the NCP81233 was busy and
unable to respond.
6 OFF This bit is set whenever the
NCP81233 is not switching.
5 VOUT
_OV
This bit gets set whenever the
NCP81233 goes into OVP
mode.
4 IOUT_
OC
This bit gets set whenever the
NCP81233 turns off due to an
over current event.
3 VIN_
UV
Not supported.
2 OT This bit gets set whenever the
NCP81233 turns off due to an
over temperature event.
1 CML This bit gets set whenever a
communications or logic fault
has occurred.
0 None
of the
Above
A fault has occurred which is not
one of the above.
High
7 VOUT This bit gets set whenever the
measured output voltage goes
outside its power good limits or
an OVP/UVP event has taken
place. i.e. any bit in Status
VOUT is set.
6 Iout/
Pout
This bit gets set whenever the
measured output current or
power exceeds its warning limit
or goes into OCP. i.e. any bit in
Status IOUT is set.
5 (Reserved for future use.)
4 (Reserved for future use.)
3 POWER
GOOD
#
The VDD_PWRGD signal is
deasserted. Same as
PowerGood in General Status.
2 (Reserved for future use.)
NCP81233
www.onsemi.com
27
Table 8. STANDARD COMMAND CODES (PART 2)
Command
Code
R/W Default Description # Bytes Comment
0x7A R 0x00 STATUS
VOUT
1
Bit Name Description
7 VOUT_OVER
VOLTAGE
FAULT
This bit gets set whenever an OVP event
takes place.
6 VOUT_OVER
VOLTAGE
WARNING
This bit gets set whenever the measured
output voltage goes above its
power-good limit.
(Reserved for future use.)
5 VOUT_
UNDER
VOLTAGE
WARNING
This bit gets set whenever the measured
output voltage goes below its
power*good limit.
(Reserved for future use.)
4 VOUT_UNDE
RVOLTAGE
FAULT
This bit gets set whenever an UVP event
takes place.
3 (Reserved for future use.)
2 (Reserved for future use.)
1 (Reserved for future use.)
0 (Reserved for future use.)
0x7B R 0x00 STATUS
IOUT
1
Bit Name Description
7 IOUT_OVER
CURRENT
FAULT
This bit gets set if the NCP81233 turns off
due to an OCP Event
6 (Reserved for future use.)
5 IOUT_OVER
CURRENT
WARNING
This bit gets set if IOUT exceeds its
programmed high warning limit.
(Reserved for future use.)
4 (Reserved for future use.)
3 (Reserved for future use.)
2 (Reserved for future use.)
1 (Reserved for future use.)
0 (Reserved for future use.)
0x7E R 0x00 STATUS
CML
1
Bit Name Description
7 INVALID
COMMAND
Invalid or unsupported command is
received. (Reserved for future use.)
6 INVALID
DATA
Invalid or unsupported data is received.
(Reserved for future use.)
5 PEC_FAULT PEC failed. (Reserved for future use.)
4 (Reserved for future use.)
3 (Reserved for future use.)
2 (Reserved for future use.)
1 OTHERS A communication fault other than the
ones listed has occurred. (Reserved for
future use.)
0 (Reserved for future use.)

NCP81233MNTXG

Mfr. #:
Manufacturer:
ON Semiconductor
Description:
Switching Controllers MULTI-PHASE CONTROLLER WI
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet