Data Sheet ADG1208/ADG1209
Rev. E | Page 13 of 21
150
–150
0 102030405060708090100110120
TEMPERATURE (°C)
LEAKAGE CURRENT (pA)
100
50
0
–50
–100
I
S
(OFF) + –
I
D
(OFF) + –
I
S
(OFF) – +
I
D
(OFF) – +
I
D
,
S
(ON) – –
I
D
,
S
(ON) + +
05713-058
V
DD
= 12V
V
SS
= 0V
V
BIAS
= 1V/10V
Figure 15. ADG1208 Leakage Currents as a Function of Temperature,
Single Supply
0
5713-035
LOGIC, IN
X
(V)
I
DD
(µA)
200
60
80
100
120
140
160
180
40
20
0
0 2 4 6 8 10121416
V
DD
= +12V
V
SS
=0V
V
DD
= +15V
V
SS
=–15V
I
DD
PER CHANNEL
T
A
=25C
Figure 16. I
DD
vs. Logic Level
V
S
(V)
CHARGE INJECTION (pC)
1.0
0
–15 15
05713-040
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
–10 –5 0 5 10
MUX (SOURCE TO DRAIN)
T
A
= 25°C
V
DD
= +15V
V
SS
= –15V
V
DD
=+5V
V
SS
= –5V
V
DD
= +12V
V
SS
=0V
Figure 17. Source-to-Drain Charge Injection vs. Source Voltage
V
S
(V)
CHARGE INJECTION (pC)
6
–6
–15 15
05713-041
–10 –5 0 5 10
DEMUX (DRAIN TO SOURCE)
T
A
= 25°C
4
2
0
–2
–4
V
DD
= +15V
V
SS
= –15V
V
DD
=+5V
V
SS
= –5V
V
DD
= +12V
V
SS
=0V
Figure 18. Drain-to-Source Charge Injection vs. Source Voltage
350
0
–40
TEMPERATURE C)
TIME (ns)
300
250
200
150
100
50
–20 0 20 40 60 80 100 120
V
DD
=+5V
V
SS
=–5V
V
DD
=+12V
V
SS
=0V
V
DD
= +15V
V
SS
= –15V
05713-052
Figure 19. t
ON
/t
OFF
Times vs. Temperature
0
5713-049
FREQUENCY (Hz)
OFF ISOLATION (dB)
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
10k 100k 1M 10M 100M 1G
V
DD
=+15V
V
SS
= –15V
T
A
=25
C
Figure 20. Off Isolation vs. Frequency
ADG1208/ADG1209 Data Sheet
Rev. E | Page 14 of 21
FREQUENCY (Hz)
CROSSTALK (dB)
20
–120
10k 1G
05713-042
100k 1M 10M 100M
0
–20
–40
–60
–80
–100
V
DD
= +15V
V
SS
= –15V
T
A
= 25°C
ADJACENT CHANNELS
NONADJACENT
CHANNELS
Figure 21. ADG1208 Crosstalk vs. Frequency
0
–120
10k 1G
FREQUENCY (Hz)
CROSSTALK (dB)
–20
–40
–60
–80
–100
100k 1M 10M 100M
ADJACENT CHANNELS
NONADJACENT
CHANNELS
05713-053
Figure 22. ADG1209 Crosstalk vs. Frequency
6.0
–10.0
10k 1G
FREQUENCY (Hz)
ON RESPONSE (dB)
–6.5
–7.0
–7.5
–8.0
–8.5
–9.0
–9.5
100k 1M 10M 100M
05713-054
Figure 23. On Response vs. Frequency
FREQUENCY (Hz)
THD + N (%)
10
1
0.1
0.01
10 100 1k 10k 100k
LOAD = 10k
T
A
= 25°C
V
DD
=+5V,V
SS
= –5V, V
S
= +3.5Vrms
V
DD
= +15V, V
SS
= –15V, V
S
=+5Vrms
05713-036
Figure 24. THD + N vs. Frequency
V
BIAS
(V)
CAPACITANCE (pF)
12
0
–15 15
05713-043
–10 –5 0 5 10
10
8
6
4
2
SOURCE/DRAIN ON
DRAIN OFF
SOURCE OFF
V
DD
= +15V
V
SS
= –15V
T
A
= 25°C
Figure 25. ADG1208 Capacitance vs. Source Voltage,
±15 V Dual Supply
V
BIAS
(V)
CAPACITANCE (pF)
12
0
012
05713-045
246810
10
8
6
4
2
V
DD
= 12V
V
SS
=0V
T
A
= 25°C
SOURCE/DRAIN ON
DRAIN OFF
SOURCE OFF
Figure 26. ADG1208 Capacitance vs. Source Voltage,
12 V Single Supply
Data Sheet ADG1208/ADG1209
Rev. E | Page 15 of 21
12
0
–5 5
V
BIAS
(V)
CAPACITANCE (pF)
10
8
6
4
2
–4 –3 –2 –1 0 1 2 3 4
V
DD
=+5V
V
SS
=–5V
T
A
= 25°C
SOURCE OFF
DRAIN OFF
SOURCE/DRAIN ON
05713-055
Figure 27. ADG1208 Capacitance vs. Source Voltage, ±5 V Dual Supply
V
BIAS
(V)
CAPACITANCE (pF)
8
0
–15 15
05713-046
–10 –5 0 5 10
V
DD
= +15V
V
SS
= –15V
T
A
= 25°C
7
6
5
4
3
2
1
SOURCE/DRAIN ON
DRAIN OFF
SOURCE OFF
Figure 28. ADG1209 Capacitance vs. Source Voltage, ±15 V Dual Supply
V
BIAS
(V)
CAPACITANCE (pF)
8
0
012
05713-047
246810
V
DD
= 12V
V
SS
=0V
T
A
= 25°C
7
6
5
4
3
2
1
SOURCE OFF
DRAIN OFF
SOURCE/DRAIN ON
Figure 29. ADG1209 Capacitance vs. Source Voltage, 12 V Single Supply
8
0
–5 5
V
BIAS
(V)
CAPACITANCE (pF)
–4 –3 –2 –1 0 1 2 3 4
V
DD
=+5V
V
SS
= –5V
T
A
=25°C
SOURCE OFF
DRAIN OFF
SOURCE/DRAIN ON
7
6
5
4
3
2
1
05713-056
Figure 30. ADG1209 Capacitance vs. Source Voltage, ±5 V Dual Supply

ADG1208YCPZ-REEL7

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Multiplexer Switch ICs 8:1 550MHz 120 Ohm iCMOS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union