DS2180A
16 of 35
193E RECEIVE MULTIFRAME TIMING Figure 15
NOTES:
1. Signaling data is updated during signaling frames on channel boundaries. RABCD outputs the LSB of
each channel word in non-signaling frames.
2. RLINK data (FDL-bit) is updated one bit time prior to odd frames and held for two frames.
DS2180A
17 of 35
RECEIVE MULTIFRAME BOUNDARY TIMING Figure 16
NOTES:
1. RLINK timing is shown for 193E; in 193S, RLINK is updated on even frame boundaries and is held
across multiframe edges.
2. Total delay from RPOS and RNEG to RSER output is 13 RCLK periods.
DS2180A
18 of 35
RSR: RECEIVE STATUS REGISTER Figure 17
(MSB) (LSB)
BVCS ECS RYEL RCL FERR B8ZSD RBL RLOS
SYMBOL POSITION NAME AND DESCRIPTION
BVCS RSR.7 Bipolar Violation Count Saturation. Set when the 8-bit counter
at BVCR saturates.
ECS RSR.6 Error Count Saturation. Set when either of the 4-bit counters at
ECR saturates.
RYEL RSR.5 Receive Yellow Alarm. Set when yellow alarm detected.
(Detected yellow alarm format determined by CCR.4 and CCR.3.)
RCL RSR.4 Receive Carrier Loss. Set when 32 consecutive 0’s appear at
RPOS and RNEG.
FERR RSR.3 Frame Bit Error. Set when F
T
(193S) or FPS (193E) bit error
occurs.
B8ZSD
RSR.2 Bipolar Eight Zero Substitution Detect. Set when B8ZS code
word detected.
RBL RSR.1 Receive Blue Alarm. Set when two consecutive frames have less
than three 0’s (total) in the data stream (F-bit positions not tested).
RLOS
RSR.0 Receive Loss of Sync. Set when resync is in process; if RCR.1=0,
RLOS transitions high on an OOF event or carrier loss indicating
auto resync.
RECEIVE ALARM REPORTING
Incoming serial data is monitored by the transceiver for alarm occurrences. Alarm conditions are reported
in two ways: via transitions on the alarm output pins and registered interrupt, in which the host controller
reads the RSR in response to an alarm-driven interrupt. Interrupts may be direct, in which the transceiver
demands service for a real-time alarm, or count-overflow triggered, in which an onboard alarm event
counter exceeds a user-programmed threshold. The user may mask individual alarm conditions by
clearing the appropriate bits in the receive interrupt mask register (RIMR).
ALARM SERVICING
The host controller must service the transceiver in order to clear an interrupt condition. Clearing
appropriate bits in the RIMR will unconditionally clear an interrupt. Direct interrupt (those driven from
real-time alarms) will be cleared when the RSR is directly read unless the alarm condition still exists.
Count-overflow interrupts (BVCS, ECS) are not cleared by a direct read of the RSR. They will be cleared
only when the user presets the appropriate count register to a value other than all 1’s. A burst read of the
RSR will not clear an interrupt condition.