MAX11606–MAX11611
Low-Power, 4-/8-/12-Channel, I
2
C,
10-Bit ADCs in Ultra-Small Packages
13
Maxim Integrated
Configuration/Setup Bytes (Write Cycle)
A write cycle begins with the bus master issuing a
START condition followed by seven address bits (Figure
7) and a write bit (R/W = 0). If the address byte is suc-
cessfully received, the MAX11606–MAX11611 (slave)
issues an acknowledge. The master then writes to the
slave. The slave recognizes the received byte as the
setup byte (Table 1) if the most significant bit (MSB) is
1. If the MSB is 0, the slave recognizes that byte as the
configuration byte (Table 2). The master can write either
one or two bytes to the slave in any order (setup byte
then configuration byte; configuration byte then setup
byte; setup byte or configuration byte only; Figure 9). If
the slave receives a byte successfully, it issues an
acknowledge. The master ends the write cycle by issu-
ing a STOP condition or a repeated START condition.
When operating in HS mode, a STOP condition returns
the bus into F/S mode (see the
HS Mode
section).
B. TWO-BYTE WRITE CYCLE
SLAVE TO MASTER
MASTER TO SLAVE
S
1
SLAVE ADDRESS A
711
W
SETUP OR
CONFIGURATION BYTE
SETUP OR
CONFIGURATION BYTE
8
P or Sr
1
A
1
MSB DETERMINES WHETHER
SETUP OR CONFIGURATION BYTE
S
1
SLAVE ADDRESS A
711
W
SETUP OR
CONFIGURATION BYTE
8
P or Sr
1
A
1
MSB DETERMINES WHETHER
SETUP OR CONFIGURATION BYTE
A
1
8
A. ONE-BYTE WRITE CYCLE
NUMBER OF BITS
NUMBER OF BITS
Figure 9. Write Cycle
BIT 7
(MSB)
BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1
BIT 0
(LSB)
REG SEL2 SEL1 SEL0 CLK BIP/UNI RST X
BIT NAME DESCRIPTION
7 REG Register bit. 1 = setup byte, 0 = configuration byte (see Table 2).
6 SEL2
5 SEL1
4 SEL0
Three bits select the reference voltage and the state of AIN_/REF
(MAX11606/MAX11607/MAX11610/MAX11611) or REF (MAX11608/MAX11609) (Table 6).
Defaulted to 000 at power-up.
3 CLK 1 = external clock, 0 = internal clock. Defaulted to 0 at power-up.
2 BIP/UNI
1 = bipolar, 0 = unipolar. Defaulted to 0 at power-up (see the Unipolar/Bipolar section).
1 RST 1 = no action, 0 = resets the configuration register to default. Setup register remains unchanged.
0 X Don’t-care bit. This bit can be set to 1 or 0.
Table 1. Setup Byte Format
MAX11606–MAX11611
Low-Power, 4-/8-/12-Channel, I
2
C,
10-Bit ADCs in Ultra-Small Packages
14
Maxim Integrated
BIT 7
(MSB)
BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1
BIT 0
(LSB)
REG SCAN1 SCAN0 CS3 CS2 CS1 CS0 SGL/DIF
BIT NAME DESCRIPTION
7 REG Register bit. 1= setup byte (see Table 1), 0 = configuration byte.
6 SCAN1
5 SCAN0
S can sel ect b i ts. Tw o b i ts sel ect the scanni ng confi g ur ati on ( Tab l e 5) . D efaul ts to 00 at p ow er - up .
4 CS3
3 CS2
2 CS1
1 CS0
Channel select bits. Four bits select which analog input channels are to be used for conversion
(Tables 3 and 4). Defaults to 0000 at power-up. For MAX11606/MAX11607, CS3 and CS2 are
internally set to 0. For the MAX11608/MAX11609, CS3 is internally set to 0.
0SGL/DIF
1 = single-ended, 0 = differential (Tables 3 and 4). Defaults to 1 at power-up. See the Single-
Ended/Differential Input section.
Table 2. Configuration Byte Format
CS3
1
CS2
1
CS1 CS0 AIN0 AIN1 AIN2 AIN3
2
AIN4 AIN5 AIN6 AIN7 AIN8 AIN9 AIN10 AIN11
2
GND
0000+ -
0001 + -
0010 + -
0011 + -
0100 + -
0101 + -
0110 + -
0111 + -
1000 + -
1001 +-
1010 +-
1011
+
-
1 1 0 0 RESERVED
1 1 0 1 RESERVED
1 1 1 0 RESERVED
1 1 1 1 RESERVED
1
For the MAX11606/MAX11607, CS3 and CS2 are internally set to 0. For the MAX11608/MAX11609, CS3 is internally set to 0.
2
When SEL1 = 1, a single-ended read of AIN3/REF (MAX11606/MAX11607) or AIN11/REF (MAX11610/MAX11611) is ignored; scan
stops at AIN2 or AIN10. This does not apply to the MAX11608/MAX11609 as each provides separate pins for AIN7 and REF.
Table 3. Channel Selection in Single-Ended Mode (SGL/DIF = 1)
MAX11606–MAX11611
Low-Power, 4-/8-/12-Channel, I
2
C,
10-Bit ADCs in Ultra-Small Packages
15
Maxim Integrated
Data Byte (Read Cycle)
A read cycle must be initiated to obtain conversion
results. Read cycles begin with the bus master issuing
a START condition followed by seven address bits and
a read bit (R/W = 1). If the address byte is successfully
received, the MAX11606–MAX11611 (slave) issues an
acknowledge. The master then reads from the slave.
The result is transmitted in two bytes; first six bits of the
first byte are high, then MSB through LSB are consecu-
tively clocked out. After the master has received the
byte(s), it can issue an acknowledge if it wants to con-
tinue reading or a not-acknowledge if it no longer wish-
es to read. If the MAX11606–MAX11611 receive a not-
acknowledge, they release SDA, allowing the master to
generate a STOP or a repeated START condition. See
the
Clock Modes
and
Scan Mode
sections for detailed
information on how data is obtained and converted.
Clock Modes
The clock mode determines the conversion clock and
the data acquisition and conversion time. The clock
mode also affects the scan mode. The state of the set-
up byte’s CLK bit determines the clock mode (Table 1).
At power-up, the MAX11606–MAX11611 are defaulted
to internal clock mode (CLK = 0).
Internal Clock
When configured for internal clock mode (CLK = 0), the
MAX11606–MAX11611 use their internal oscillator as the
conversion clock. In internal clock mode, the MAX11606–
MAX11611 begin tracking the analog input after a valid
address on the eighth rising edge of the clock. On the
falling edge of the ninth clock, the analog signal is
acquired and the conversion begins. While converting the
analog input signal, the MAX11606–MAX11611 holds SCL
low (clock stretching). After the conversion completes, the
results are stored in internal memory. If the scan mode is
set for multiple conversions, they all happen in succession
with each additional result stored in memory. The
MAX11606/MAX11607 contain four 10-bit blocks of memo-
ry, the MAX11608/MAX11609 contain eight 10-bit blocks of
memory, and the MAX11610/MAX11611 contain twelve 10-
bit blocks of memory. Once all conversions are complete,
the MAX11606–MAX11611 release SCL, allowing it to be
pulled high. The master may now clock the results out
of the memory in the same order the scan conversion
has been done at a clock rate of up to 1.7MHz. SCL is
stretched for a maximum of 7.6µs per channel (see
Figure 10).
CS3
1
CS2
1
CS1 CS0 AIN0 AIN1 AIN2 AIN3
2
AIN4 AIN5 AIN6 AIN7 AIN8 AIN9 AIN10 AIN11
2
0000+-
0001 -+
0010 + -
0011 -+
0100 + -
0101 - +
0110 +-
0111 -+
1000 +-
1001 -+
1010 +-
1011 -+
1 1 0 0 RESERVED
1 1 0 1 RESERVED
1 1 1 0 RESERVED
1 1 1 1 RESERVED
1
For the MAX11606/MAX11607, CS3 and CS2 are internally set to 0. For the MAX11608/MAX11609, CS3 is internally set to 0.
2
When SEL1 = 1, a differential read between AIN2 and AIN3/REF (MAX11606/MAX11607) or AIN10 and AIN11/REF
(MAX11610/MAX11611) returns the difference between GND and AIN2 or AIN10, respectively. For example, a differential read of 1011
returns the negative difference between AIN10 and GND. This does not apply to the MAX11608/MAX11609 as each provides separate
pins for AIN7 and REF. In differential scanning, the address increments by 2 until the limit set by CS3–CS1 has been reached.
Table 4. Channel Selection in Differential Mode (SGL/DIF = 0)