REV. F–4–
AD7712–SPECIFICATIONS
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD7712 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
Parameter A, S Versions
1
Unit Conditions/Comments
POWER REQUIREMENTS
Power Supply Voltages
AV
DD
Voltage
18
+5 to +10 V nom ±5% for Specified Performance
DV
DD
Voltage
19
+5 V nom ±5% for Specified Performance
AV
DD
– V
SS
Voltage +10.5 V max For Specified Performance
Power Supply Currents
AV
DD
Current 4 mA max
DV
DD
Current 4.5 mA max
V
SS
Current 1.5 mA max V
SS
= –5 V
Power Supply Rejection
20
Rejection w.r.t. AGND; Assumes V
BIAS
Is Fixed
Positive Supply (AV
DD
and DV
DD
)
21
dB typ
Negative Supply (V
SS
)90 dB typ
Power Dissipation
Normal Mode 45 mW max AV
DD
= DV
DD
= +5 V, V
SS
= 0 V; Typically 25 mW
Normal Mode 52.5 mW max AV
DD
= DV
DD
= +5 V, V
SS
= –5 V; Typically 30 mW
Standby (Power-Down) Mode
22
200 µW max AV
DD
= DV
DD
= +5 V, V
SS
= 0 V or –5 V; Typically 100 µW
NOTES
18
The AD7712 is specified with a 10 MHz clock for AV
DD
voltages of +5 V ± 5%. It is specified with an 8 MHz clock for AV
DD
voltages greater than 5.25 V and less
than 10.5 V. Operating with AV
DD
voltages in the range 5.25 V to 10.5 V is guaranteed only over the 0 ⬚C to 70⬚C temperature range.
19
The ± 5% tolerance on the DV
DD
input is allowed provided that DV
DD
does not exceed AV
DD
by more than 0.3 V.
20
Measured at dc and applies in the selected passband. PSRR at 50 Hz will exceed 120 dB with filter notches of 10 Hz, 25 Hz, or 50 Hz. PSRR at 60 Hz will
exceed 120 dB with filter notches of 10 Hz, 30 Hz, or 60 Hz.
21
PSRR depends on gain: gain of 1 = 70 dB typ; gain of 2 = 75 dB typ; gain of 4 = 80 dB typ; gains of 8 to 128 = 85 dB typ. These numbers can be improved
(to 95 dB typ) by deriving the V
BIAS
voltage (via Zener diode or reference) from the AV
DD
supply.
22
Using the hardware STANDBY pin. Standby power dissipation using the software standby bit (PD) of the Control Register is 8 mW typ.
Specifications subject to change without notice.
ABSOLUTE MAXIMUM RATINGS*
(T
A
= 25°C, unless otherwise noted.)
AV
DD
to DV
DD
. . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
AV
DD
to V
SS
. . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
AV
DD
to AGND . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
AV
DD
to DGND . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
DV
DD
to AGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
DV
DD
to DGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
V
SS
to AGND . . . . . . . . . . . . . . . . . . . . . . . . . +0.3 V to –6 V
V
SS
to DGND . . . . . . . . . . . . . . . . . . . . . . . . . +0.3 V to –6 V
AIN1 Input Voltage to AGND . . . V
SS
– 0.3 V to AV
DD
+ 0.3 V
Reference Input Voltage to AGND . . V
SS
– 0.3 V to AV
DD
+ 0.3 V
REF OUT to AGND . . . . . . . . . . . . . . . . . . . . –0.3 V to AV
DD
ORDERING GUIDE
Model Temperature Range Package Options*
AD7712AN –40°C to +85°C N-24
AD7712AR –40°C to +85°C RW-24
AD7712AR-REEL –40°C to +85°C RW-24
AD7712AR-REEL7 –40°C to +85°C RW-24
AD7712AQ –40°C to +85°C Q-24
AD7712SQ –55°C to +125°C Q-24
EVAL-AD7712EB Evaluation Board
*N = PDIP, Q = CERDIP; RW = SOIC.
Digital Input Voltage to DGND . . . . . –0.3 V to AV
DD
+ 0.3 V
Digital Output Voltage to DGND . . . . –0.3 V to DV
DD
+ 0.3 V
Operating Temperature Range
Commercial (A Version) . . . . . . . . . . . . . . . –40°C to +85°C
Extended (S Version) . . . . . . . . . . . . . . . . . –55°C to +125°C
Storage Temperature Range . . . . . . . . . . . . . –65°C to +150°C
Lead Temperature (Soldering, 10 secs) . . . . . . . . . . . . . 300°C
Power Dissipation (Any Package) to 75°C . . . . . . . . . . 450 mW
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of the specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.