MC10EP446, MC100EP446
http://onsemi.com
9
Table 11. 100EP DC CHARACTERISTICS, PECL V
CC
= 5.0 V, V
EE
= 0 V (Note 14)
Symbo
Characteristic
−40°C 25°C 85°C
Uni
Min Typ Max Min Typ Max Min Typ Max
I
EE
Power Supply Current 90 110 130 90 110 130 95 115 135 mA
V
OH
Output HIGH Voltage (Note 15) 3855 3980 4105 3855 3980 4105 3855 3980 4105 mV
V
OL
Output LOW Voltage (Note 15) 3005 3180 3305 3005 3180 3305 3005 3180 3305 mV
V
IH
Input HIGH Voltage (Single−Ended)
CMOS
PECL
TTL
3500
3775
2000
5000
5000
5000
3500
3775
2000
5000
5000
5000
3500
3775
2000
5000
5000
5000
mV
V
IL
Input LOW Voltage (Single−Ended)
CMOS
PECL
TTL
0
3005
0
1500
3375
800
0
3005
0
1500
3375
800
0
3005
0
1500
3375
800
mV
V
BB
Output Voltage Reference 3475 3575 3675 3475 3575 3675 3475 3575 3675 mV
V
IHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(Note 16)
2.0 5.0 2.0 5.0 2.0 5.0 V
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current 0.5 0.5 0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
14.Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +2.0 V to −0.5 V.
15.All loading with 50 W to V
CC
− 2.0 V.
16.V
IHCMR
min varies 1:1 with V
EE
, V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential
input signal.
Table 12. 100EP DC CHARACTERISTICS, NECL V
CC
= 0 V, V
EE
= −5.5 V to −3.0 V (Note 17)
Symbo
Characteristic
−40°C 25°C 85°C
Uni
Min Typ Max Min Typ Max Min Typ Max
I
EE
Power Supply Current 90 110 130 90 110 130 95 115 135 mA
V
OH
Output HIGH Voltage (Note 18) −1145 −1020 −895 −1145 −1020 −895 −1145 −1020 −895 mV
V
OL
Output LOW Voltage (Note 18) −1995 −1820 −1695 −1995 −1820 −1695 −1995 −1820 −1695 mV
V
IH
Input HIGH Voltage (Single−Ended) −1225 −880 −1225 −880 −1225 −880 mV
V
IL
Input LOW Voltage (Single−Ended) −1995 −1625 −1995 −1625 −1995 −1625 mV
V
BB
Output Voltage Reference −1525 −1425 −1325 −1525 −1425 −1325 −1525 −1425 −1325 mV
V
IHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(Note 19)
V
EE
+2.0 0.0 V
EE
+2.0 0.0 V
EE
+2.0 0.0 V
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current 0.5 0.5 0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
17.Input and output parameters vary 1:1 with V
CC
.
18.All loading with 50 W to V
CC
− 2.0 V.
19.V
IHCMR
min varies 1:1 with V
EE
, V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential
input signal.