Table 19. Register 26 (Extended Control 3)
Bit Name Description
Hardware
Reset
Software
Reset Details
26.15:8
RO
N/A to SFP
Module
00000000 Retain
26.7:3
R/W
N/A to SFP
Module
00001 Update When writing to register 26, be
sure to preserve the values of
these bits. Changes to these
values can interrupt the normal
operation of the SFP module.
26.2:0
R/W
RD+/- Output
Amplitude
000=0.50V
001=0.60V
010=0.70V
011=0.80V
100=0.90V
101=1.00V
110=1.10V
111=1.20V
010 Retain All voltages measured peak-to-
peak into a 100-ohm load.
Table 20. Register 27 (Extended Status 2)
Bit Name Description Hardware Reset
Software
Reset Details
27.15:13
RO/SC
N/A to SFP
Module
100 Update
(27.15),
Retain
(27.14:13)
When writing to register
27, be sure to preserve the
values of these bits. Changes
to these values can interrupt
the normal operation of the
SFP module.
27.12
R/W
1000BASE-X
Auto-negotiation
Bypass Enable
1 = Enabled
0 = Disabled
1 Update If enabled, BASE-X link will
come up after 200 ms even
if BASE-X auto-negotiation
fails. When writing to register
27, be sure to preserve the
values of this bit. Changes to
this value can interrupt the
normal operation of the SFP
module.
27.11
RO
1000BASE-X
Auto-negotiation
Bypass Status
1 = BASE-X auto-negotia-
tion failed and BASE-X link
came up becase bypass
mode timer expired
0 = BASE-X link came up
because regular BASE-X
auto-negotiation was
completed
0 Retain See bit 27.12.
27.10:0
R/W
N/A to SFP
Module
0000001000
(ABCU-57x0xxZ)
0000000100
(ABCU-57x1xxZ)
Update When writing to register
27, be sure to preserve the
values of these bits. Changes
to these values can interrupt
the normal operation of the
SFP module.
23
Table 21. Register 28 (Cable Diagnostic 2)
Bit Name Description
Hardware
Reset
Software
Reset Details
28.15
R/W
Enable Cable
Diagnostic Test
1 = Enable test
0 = disable test
0 0 The test can only be performed when the
link is down. If the link partner is trying
to auto-negotiate or if the link partner is
sending out idle link pulses, the test will
proceed.
28.14:13
RO
Status 11 = Test fail
10 = Open detected
in twisted pair
01 = Short detected
in twisted pair
00 = No short or
open detected in
twisted pair
00 00 The twisted pair under test is speci ed in
register 22.
28.12:8
RO
Re ected
Magnitude
11111 = 1 V
10000 = 0 V
00000= -1 V
00000 00000 The twisted pair under test is speci ed in
register 22.
28.7:0
RO
Distance Distance to the
short or open
00000000 00000000 The distance is given in meters by 13/16
* (decimal equivalent of 28.7:0) + 32 .The
twisted pair under test is speci ed in
register 22. If no short or open is detected,
these bits are 0s.
24
Figure 7. Module Drawing
Figure 8. Temperature Measurement Point
NOTES:
1. IT IS ACCEPTABLE TO MEASURE THE TEMPERATURE OF THE HOUSING THROUGH THE LABEL.
THE LABEL IS THIN AND MAKES LITTLE DIFFERENCE TO THE TEMPERATURE MEASURED.
67.9
±0.2
13.6
±0.1
13.4
±0.1
47.50
±0.15
8.5
±0.1
1
±0.10
2.25
±0.10
13.95 MAX.
9.2
±0.1
34.6
±0.2
41.8
±0.15
22.3
±0.5
41.5
±0.5
25.2
±0.5
C
L
TEMPERATURE MEASUREMENT POINT

ABCU-5730ARZ

Mfr. #:
Manufacturer:
Description:
Fiber Optic Transmitters, Receivers, Transceivers CU B2 LOS ENBLD SGMII DISAB-40+85C
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union