7
Absolute Maximum Ratings
Parameter Symbol Minimum Typical Maximum Unit Notes
Storage Temperature T
S
-40 +85 °C Note 1
Case Temperature T
C
-40 +85 °C Note 1 ,2
Relative Humidity RH 5 95 % Note 1
Module Supply Voltage V
CC
T,R -0.5 3.6 V Note 1, 2
Data/Control Input Voltage V
I
-0.5 V
CC
V Note 1
Sense Output Current - MOD-DEF2 5.0 mA
Recommended Operating Conditions
Parameter Symbol Minimum Typical Maximum Unit Notes
Case Temperature T
C
-5
-40
70
85
°C
°C
Note 3
Module Supply Voltage V
CC
T,R 3.135 3.3 3.465 V Note 3
Data Rate 1.25 Gb/s Note 3
Transceiver Electrical Characteristics
(T
C
= -5 °C to +70 °C, V
CC
T,R = 3.3 V ± 5%) (Tc = -40 °C to +85°C, VccT,R = 3.3 V +/- 5%)
Parameter Symbol Minimum Typical Maximum Unit Notes
AC Electrical Characteristics
Power Supply Noise Rejection
(peak-peak)
PSNR 100 mV Note 4
DC Electrical Characteristics
Module supply current
(T
C
= -5 °C to +70 °C, V
CC
T,R = 3.3 V ± 5%)
(Tc = -40 °C to +85°C, VccT,R = 3.3 V +/- 5%)
I
CC
350
370
mA
Power Dissipation
(T
C
= -5 °C to +70 °C, V
CC
T,R = 3.3 V ± 5%)
(Tc = -40 °C to +85°C, VccT,R = 3.3 V +/- 5%)
P
DISS
1100
1150
mW
Sense Outputs:
MOD-DEF2
RX_LOS
V
OH
2.0 V
CC
T, R+ 0.3 V Note 5
V
OL
0 0.4
Control Inputs:
Transmitter Disable(TX_DISABLE),
MOD-DEF1, 2
V
IH
2.0 V
CC
V Note 5
V
IL
0 0.8 V
Notes:
1. Absolute Maximum Ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short
period of time. See Reliability Data Sheet for speci c reliability performance.
2. Between Absolute Maximum Ratings and the Recommended Operating Conditions functional performance is not intended, device reliability
is not implied, and damage to the device may occur over an extended period of time.
3. Operating conditions will vary, depending on model. Recommended Operating Conditions are those values outside of which functional perfor-
mance is not intended, device reliability is not implied, and damage to the device may occur over an extended period of time. See Reliability
Data Sheet for speci c reliability performance later when it is ready.
4. MSA-speci ed  lter is required on the host board to achieve PSNR performance over the frequency range 10 Hz to 2 MHz.
5. LVTTL, external 4.7-10 K pull-Up resistor required for MOD-DEF 1 and MOD-DEF 2.
8
Transmitter and Receiver Electrical Characteristics
(T
C
= -5 °C to +70 °C, V
CC
T,R = 3.3 V ± 5%) (Tc = -40 °C to +85°C, VccT,R = 3.3 V +/- 5%)
Parameter Symbol Minimum Typical Maximum Unit Notes
Data Input:
Transmitter Di erential
Input Voltage (TD +/-)
V
I
330
2400 mV Note 1
Data Output:
Receiver Di erential
Output Voltage (RD +/-)
V
O
370 735 2000 mV Note 2
Receive Data Rise & Fall Times
(Receiver)
Trf 100 250 ps Note 3
Transceiver Timing Characteristics
(T
C
= -5 °C to +70 °C, V
CC
T,R = 3.3 V ± 5%) (Tc = -40 °C to +85°C, VccT,R = 3.3 V +/- 5%)
Parameter Symbol Minimum Typical Maximum Unit Notes
Tx Disable Assert Time t_o NA Note 4
Tx Disable Negate Time t_on NA Note 4
Module Reset Assert Time t_o _rst 10
s
Note 5
Module Reset Negate Time t_on_rst 300 ms Note 6
Time to initialize t_init 300 ms
Tx Fault Assert Time t_fault NA Note 7
Tx Disable to Reset t_reset NA Note 7
LOS Assert Time t_loss_on NA Note 7
LOS De-assert Time t_loss_o NA Note 7
Rate Select Change Time t_ratesel NA Note 7
Serial ID Clock Rate F_serial_clock 100 kHz
Notes:
1. Internally ac coupled and terminated (100 Ohm di erential). These levels are compatible with CML and LVPECL voltage swings.
2. Internally ac coupled with an external 100 ohm di erential load termination.
3. 20%-80% rise and fall times measured with a 500 MHz signal utilizing a 1010 pattern.
4. Tx Disable function as described in the SFP MSA is not used in the 1000BASE-T module.
5. Time from rising edge of Tx Disable until link comes down.
6. Time from falling edge of Tx Disable until auto-negotiation starts.
7. Not used in the 1000BASE-T module
9
Figure 6. Transceiver Timing Diagrams (Module Installed Except Where Noted)
V
CC
> 3.15 V
t_init
POWER SAVING
(TX_DISABLE)
TRANSMITTED SIGNAL
(AUTO-NEGOTIATION
BEGINS)
t-init: MODULE HOT-PLUGGED OR VOLTAGE APPLIED AFTER INSERTION, WHEN TX_DISABLE IS NEGATED
V
CC
> 3.15 V
t_init
TX_DISABLE
TRANSMITTED SIGNAL
(AUTO-NEGOTIATION
BEGINS)
t-init: VOLTAGE APPLIED WHEN TX_DISABLE IS ASSERTED
t_on_rst
t_o_rst
Tx_DISABLE
TRANSMITTED SIGNAL
(AUTO-NEGOTIATION
BEGINS ON RISING EDGE)
t_o_rst & t_on_rst: TX_DISABLE (RESET) ASSERTED THEN DE-ASSERTED
t_on_rst

ABCU-5730ARZ

Mfr. #:
Manufacturer:
Description:
Fiber Optic Transmitters, Receivers, Transceivers CU B2 LOS ENBLD SGMII DISAB-40+85C
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union