DocID11090 Rev 4 19/26
M34F04 DC and AC parameters
25
6 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Figure 8. AC measurement I/O waveform
Table 5. Operating conditions
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage 2.5 5.5 V
T
A
Ambient Operating Temperature –40 85 °C
Table 6. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load Capacitance 100 pF
Input Rise and Fall Times 50 ns
Input Levels 0.2V
CC
to 0.8V
CC
V
Input and Output Timing Reference Levels 0.3V
CC
to 0.7V
CC
V
Table 7. Input parameters
Symbol Parameter
(1)(2)
1. TA = 25 °C, f = 400 kHz
2. Sampled only, not 100% tested.
Test condition Min. Max. Unit
C
IN
Input Capacitance (SDA) 8 pF
C
IN
Input Capacitance (other pins) 6 pF
Z
WCL
WC Input Impedance V
IN
< 0.3V
CC
570kΩ
Z
WCH
WC Input Impedance V
IN
> 0.7V
CCs
500 kΩ
t
NS
Pulse width ignored
(Input Filter on SCL and SDA)
Single glitch 100 ns
!)"
6
##
6
##
6
##
6
##
)NPUTAND/UTPUT
4IMING2EFERENCE,EVELS
)NPUT,EVELS