DocID11090 Rev 4 19/26
M34F04 DC and AC parameters
25
6 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Figure 8. AC measurement I/O waveform
Table 5. Operating conditions
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage 2.5 5.5 V
T
A
Ambient Operating Temperature –40 85 °C
Table 6. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load Capacitance 100 pF
Input Rise and Fall Times 50 ns
Input Levels 0.2V
CC
to 0.8V
CC
V
Input and Output Timing Reference Levels 0.3V
CC
to 0.7V
CC
V
Table 7. Input parameters
Symbol Parameter
(1)(2)
1. TA = 25 °C, f = 400 kHz
2. Sampled only, not 100% tested.
Test condition Min. Max. Unit
C
IN
Input Capacitance (SDA) 8 pF
C
IN
Input Capacitance (other pins) 6 pF
Z
WCL
WC Input Impedance V
IN
< 0.3V
CC
570kΩ
Z
WCH
WC Input Impedance V
IN
> 0.7V
CCs
500 kΩ
t
NS
Pulse width ignored
(Input Filter on SCL and SDA)
Single glitch 100 ns
!)"
6
##
6
##
6
##
6
##
)NPUTAND/UTPUT
4IMING2EFERENCE,EVELS
)NPUT,EVELS
DC and AC parameters M34F04
20/26 DocID11090 Rev 4
Table 8. DC characteristics
Symbol Parameter
Test condition
(in addition to those in Table 5)
Min. Max. Unit
I
LI
Input Leakage Current
(SCL, SDA)
V
IN
= V
SS
or
V
CC
± 2 µA
I
LO
Output Leakage Current V
OUT
= V
SS
or
V
CC
,
SDA in Hi-Z ± 2 µA
I
CC
Supply Current
V
CC
=2.5V, f
c
=400kHz
(rise/fall time < 30ns)
1mA
I
CC1
Stand-by Supply Current V
IN
= V
SS
or
V
CC
, V
CC
= 2.5 V 2
(1)
1. 0.5 µA for products identified with process letters S or G
µA
V
IL
Input Low Voltage
(E2, E1, SCL, SDA)
–0.3 0.3V
CC
V
V
IH
Input High Voltage
(E2, E1, SCL, SDA, WC)
0.7V
CC
V
CC
+1 V
V
OL
Output Low Voltage I
OL
= 2.1 mA, V
CC
= 2.5 V 0.4 V
Table 9. AC characteristics
Test conditions specified in Table 5 and Table 6
Symbol Alt. Parameter Min. Max. Unit
f
C
f
SCL
Clock Frequency 400 kHz
t
CHCL
t
HIGH
Clock Pulse Width High 600 ns
t
CLCH
t
LOW
Clock Pulse Width Low 1300 ns
t
DL1DL2
(1)
1. Sampled only, not 100% tested.
t
F
SDA Fall Time 20 300 ns
t
DXCX
t
SU:DAT
Data In Set Up Time 100 ns
t
CLDX
t
HD:DAT
Data In Hold Time 0 ns
t
CLQX
t
DH
Data Out Hold Time 100 ns
t
CLQV
(2)
2. To avoid spurious START and STOP conditions, a minimum delay is placed between SCL=1 and the falling
or rising edge of SDA.
t
AA
Clock Low to Next Data Valid (Access Time) 900 ns
t
CHDX
(3)
3. For a reSTART condition, or following a Write cycle.
t
SU:STA
Start Condition Set Up Time 600 ns
t
DLCL
t
HD:STA
Start Condition Hold Time 600 ns
t
CHDH
t
SU:STO
Stop Condition Set Up Time 600 ns
t
DHDL
t
BUF
Time between Stop Condition and Next Start
Condition
1300 ns
t
W
t
WR
Write Time 5 ms
DocID11090 Rev 4 21/26
M34F04 DC and AC parameters
25
Figure 9. AC waveforms
Figure 10. Maximum R
L
value versus bus capacitance (C
BUS
) for an I
2
C bus
!)
6
##
#
"53
3$!
2
,
-!34%2
2
,
3#,
#
"53




#
"53
P&
-AXIMUM20VALUEK½


FCK(Z
FCK(Z

M34F04-WMN6TP

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
EEPROM 4Kbit Serial EE
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet